CoChat

MR Imaging of Iron Phagocytosis in Intraluminal Thrombi of Abdominal Aortic Aneurysms in Humans

Nchimi, Alain, Defawe, Olivier, Brisbois, Denis, Broussaud, Thomas K. Y., Defraigne, Jean-Olivier, Magotteaux, Paul, Massart, Brigitte, Serfaty, Jean-Michel, Houard, Xavier, Michel, Jean-Baptiste, Sakalihasan, Natzi · 2010 · Radiology
Cited by 62

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively determine if superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging could help visualize leukocyte phagocytic activities in human abdominal aortic aneurysms (AAAs). MATERIALS AND METHODS: This study was approved by the institutional ethics committee; all patients gave informed consent. Preoperative MR imaging data, including unenhanced and SPIO-enhanced T1-, T2*-, and T2-weighted transverse images of the entire AAA, obtained 1 hour after contrast enhancement from 15 patients (mean age, 72.7 years +/- 8.2; range, 60-83 years), 10 men (mean age, 73.5 years +/- 7.9; range, 60-83 years) and five women (mean age, 71.2 years +/- 9.4; range 60-82), were retrospectively evaluated. Morphologic appearance and semiquantitative and contrast-to-noise ratio (CNR) analyses of the thrombi were performed. Thrombi were analyzed semiquantitatively at microscopy after staining with hematoxylin-eosin, CD68, and CD66b. Levels of promatrix metalloproteinase (pro-MMP)-2 and pro-MMP-9, MMP-2 and MMP-9, and their mRNA located in the thrombus were assessed by using zymography and quantitative reverse transcriptase polymerase chain reaction analysis. Nonparametric statistics of the Spearman rank correlation were calculated to evaluate correlations between the aneurysm thrombus signal level decrease after SPIO and the levels of CD68(+), CD66b(+) cells, pro-MMP-2 and pro-MMP-9, MMP-2 and MMP-9, and MMP-9 mRNA. RESULTS: The pre-SPIO CNRs in the luminal sublayer of the thrombus and the deeper thrombus were -10.20 +/- 12.69 and -5.68 +/-10.38, respectively. After SPIO, the CNRs decreased to -21.34 +/-13.07 (P < .001) and -12.44 +/- 14.56, respectively (P < .012). There was a significant linear correlation between the thrombus signal level decrease and the levels of CD68(+) and CD66b(+) cells, pro-MMP-9, and MMP-9 mRNA (P < .05). CONCLUSION: MR imaging allows in vivo demonstration of SPIO uptake at the luminal interface of the thrombus. This uptake is correlated to the abundance of leukocytes. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.09090657/-/DC1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.09090657

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 62

Metadata

Authors
Nchimi, A., Defawe, O., Brisbois, D., Broussaud, T. K. Y., Defraigne, J.-O., Magotteaux, P., Massart, B., Serfaty, J.-M., Houard, X., Michel, J.-B., & Sakalihasan, N.
Venue
Radiology
Published
2010-03
Volume
254
Issue
3
Pages
973-981
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2057833873
Cited by
62
References
2
FWCI
5.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.