CoChat

Renal Inflammation: Targeted Iron Oxide Nanoparticles for Molecular MR Imaging in Mice

Open access
Serkova, Natalie J., Renner, Brandon, Larsen, Brian A., Stoldt, Conrad R., Hasebroock, Kendra M., Bradshaw-Pierce, Erica L., Holers, V. Michael, Thurman, Joshua M. · 2010 · Radiology
Cited by 73

The DOI matches its Crossref record.

Abstract

PURPOSE: To determine the feasibility of T2-weighted magnetic resonance (MR) imaging in the noninvasive quantification of renal inflammation by using superparamagnetic iron oxide (SPIO) nanoparticles targeted to tissue-bound C3 activation fragments in a mouse model of lupus nephritis. MATERIALS AND METHODS: All animal procedures were approved by the University of Colorado-Denver animal care and use committee. SPIO nanoparticles were encapsulated by using amine-functionalized phospholipids. A recombinant protein containing the C3d-binding region of complement receptor type 2 (CR2) was then conjugated to the surface of the SPIO nanoparticle. Five MRL/lpr mice (a model of lupus nephritis) and six C57BL/6 wild-type mice were assessed with T2-weighted MR imaging at baseline and after SPIO injection. The same five MRL/lpr mice and three C57BL/6 mice also underwent MR imaging after injection of CR2-targeted SPIO. A series of T2-weighted pulses with 16 echo times was used to enable precise T2 mapping and calculation of T2 relaxation times in the cortex and outer and inner medulla of the kidneys, as well as in the spleen, muscle, and fat. The effects of treatment and animal genotype on T2 relaxation times were analyzed with repeated-measures analysis of variance. RESULTS: At baseline, the T2-weighted signal intensity in the kidneys of MRL/lpr mice was higher than that in the kidneys of wild-type mice. Injection of untargeted SPIO did not alter the T2-weighted signal in the kidneys in either strain of mice. Injection of CR2-targeted SPIO in MRL/lpr mice, however, caused a significant accumulation of targeted iron oxide with a subsequent decrease in T2 relaxation times in the cortex and outer and inner medulla of the kidneys. No changes in T2 relaxation time were observed in the wild-type mice after injection of targeted SPIO. CONCLUSION: Injection of CR2-conjugated SPIO caused a significant reduction in T2-weighted MR imaging signal and T2 relaxation time in nephritic kidneys.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.09091134

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 73

Metadata

Authors
Serkova, N. J., Renner, B., Larsen, B. A., Stoldt, C. R., Hasebroock, K. M., Bradshaw-Pierce, E. L., Holers, V. M., & Thurman, J. M.
Venue
Radiology
Published
2010-05
Volume
255
Issue
2
Pages
517-526
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2135897014
Cited by
73
References
0
FWCI
4.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Renal Inflammation: Targeted Iron Oxide Nanoparticles for Molecular MR Imaging in Mice. https://app.cochat.ai/papers/10.1148/radiol.09091134
The paper
Serkova, N. J., Renner, B., Larsen, B. A., Stoldt, C. R., Hasebroock, K. M., Bradshaw-Pierce, E. L., Holers, V. M., & Thurman, J. M. (2010). Renal Inflammation: Targeted Iron Oxide Nanoparticles for Molecular MR Imaging in Mice. Radiology. https://doi.org/10.1148/radiol.09091134

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.