The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Addressing Overutilization in Medical Imaging
Abstract
The growth in medical imaging over the past 2 decades has yielded unarguable benefits to patients in terms of longer lives of higher quality. This growth reflects new technologies and applications, including high-tech services such as multisection computed tomography (CT), magnetic resonance (MR) imaging, and positron emission tomography (PET). Some part of the growth, however, can be attributed to the overutilization of imaging services. This report examines the causes of the overutilization of imaging and identifies ways of addressing the causes so that overutilization can be reduced. In August 2009, the American Board of Radiology Foundation hosted a 2-day summit to discuss the causes and effects of the overutilization of imaging. More than 60 organizations were represented at the meeting, including health care accreditation and certification entities, foundations, government agencies, hospital and health systems, insurers, medical societies, health care quality consortia, and standards and regulatory agencies. Key forces influencing overutilization were identified. These include the payment mechanisms and financial incentives in the U.S. health care system; the practice behavior of referring physicians; self-referral, including referral for additional radiologic examinations; defensive medicine; missed educational opportunities when inappropriate procedures are requested; patient expectations; and duplicate imaging studies. Summit participants suggested several areas for improvement to reduce overutilization, including a national collaborative effort to develop evidence-based appropriateness criteria for imaging; greater use of practice guidelines in requesting and conducting imaging studies; decision support at point of care; education of referring physicians, patients, and the public; accreditation of imaging facilities; management of self-referral and defensive medicine; and payment reform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901249 · Cited by 1,338
Health Professions Education: A Bridge to Quality
Greiner, A. C., & Knebel, E. (2004) · Journal For Healthcare Quality · doi:10.1111/j.1945-1474.2004.tb00473.x · Cited by 1,074
The Perfect Storm of Overutilization
Emanuel, E. J. (2008) · JAMA · doi:10.1001/jama.299.23.2789 · Cited by 390
Sustainability of medical imaging
Picano, E. (2004) · BMJ · doi:10.1136/bmj.328.7439.578 · Cited by 321
Sistrom, C. L., Dang, P. A., Weilburg, J. B., Dreyer, K. J., Rosenthal, D. I., & Thrall, J. H. (2009) · Radiology · doi:10.1148/radiol.2511081174 · Cited by 279
Self-citationThe New Era of Medical Imaging — Progress and Pitfalls
Iglehart, J. K. (2006) · New England Journal of Medicine · doi:10.1056/nejmhpr061219 · Cited by 270
Keehan, S., Sisko, A., Truffer, C., Smith, S., Cowan, C., Poisal, J., Clemens, M. K., & the National Health Expenditure Accounts Projections Team (2008) · Health Affairs · doi:10.1377/hlthaff.27.2.w145 · Cited by 194
Sistrom, C. L., Dreyer, K. J., Dang, P. A., Weilburg, J. B., Boland, G. W., Rosenthal, D. I., & Thrall, J. H. (2009) · Radiology · doi:10.1148/radiol.2532090200 · Cited by 136
Self-citation
Cited by
McDonald, R. J., Schwartz, K. M., Eckel, L. J., Diehn, F. E., Hunt, C. H., Bartholmai, B. J., Erickson, B. J., & Kallmes, D. F. (2015) · Academic Radiology · doi:10.1016/j.acra.2015.05.007 · Cited by 460
Self-citationCancer risks associated with external radiation from diagnostic imaging procedures
Linet, M. S., Slovis, T. L., Miller, D. L., Kleinerman, R., Lee, C., Rajaraman, P., & Berrington de Gonzalez, A. (2012) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21132 · Cited by 420
Projected Lifetime Cancer Risks From Current Computed Tomography Imaging
Smith-Bindman, R., Chu, P. W., Azman Firdaus, H., Stewart, C., Malekhedayat, M., Alber, S., Bolch, W. E., Mahendra, M., Berrington de González, A., & Miglioretti, D. L. (2025) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2025.0505 · Cited by 358
Hauptmann, M., Byrnes, G., Cardis, E., Bernier, M.-O., Blettner, M., Dabin, J., Engels, H., Istad, T. S., Johansen, C., Kaijser, M., et al. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(22)00655-6 · Cited by 273
Medical Errors, Malpractice, and Defensive Medicine: An Ill-Fated Triad
Berlin, L. (2017) · Diagnosis · doi:10.1515/dx-2017-0007 · Cited by 132
Metadata
- Authors
- Hendee, W. R., Becker, G. J., Borgstede, J. P., Bosma, J., Casarella, W. J., Erickson, B. A., Maynard, C. D., Thrall, J. H., & Wallner, P. E.
- Venue
- Radiology
- Published
- 2010-10
- Volume
- 257
- Issue
- 1
- Pages
- 240-245
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2119016000
- Cited by
- 619
- References
- 13
- FWCI
- 48.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Addressing Overutilization in Medical Imaging. https://app.cochat.ai/papers/10.1148/radiol.10100063
- The paper
- Hendee, W. R., Becker, G. J., Borgstede, J. P., Bosma, J., Casarella, W. J., Erickson, B. A., Maynard, C. D., Thrall, J. H., & Wallner, P. E. (2010). Addressing Overutilization in Medical Imaging. Radiology. https://doi.org/10.1148/radiol.10100063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.