Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 290

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T

Open access
Yokoo, Takeshi, Shiehmorteza, Masoud, Hamilton, Gavin, Wolfson, Tanya, Schroeder, Michael E., Middleton, Michael S., Bydder, Mark, Gamst, Anthony C., Kono, Yuko, Kuo, Alexander, Patton, Heather M., Horgan, Santiago, Lavine, Joel E., Schwimmer, Jeffrey B., Sirlin, Claude B.·2011·Radiology

Abstract

PURPOSE: To compare the accuracy of several magnetic resonance (MR) imaging-based methods for hepatic proton-density fat fraction (FF) estimation at 3.0 T, with spectroscopy as the reference technique. MATERIALS AND METHODS: This prospective study was institutional review board approved and HIPAA compliant. Informed consent was obtained. One hundred sixty-three subjects (39 with known hepatic steatosis, 110 with steatosis risk factors, 14 without risk factors) underwent proton MR spectroscopy and non-T1-weighted gradient-echo MR imaging of the liver. At spectroscopy, the reference FF was determined from frequency-selective measurements of fat and water proton densities. At imaging, FF was calculated by using two-, three-, or six-echo methods, with single-frequency and multifrequency fat signal modeling. The three- and six-echo methods corrected for T2*; the two-echo methods did not. For each imaging method, the fat estimation accuracy was assessed by using linear regression between the imaging FF and spectroscopic FF. Binary classification accuracy of imaging was assessed at four reference spectroscopic thresholds (0.04, 0.06, 0.08, and 0.10 FF). RESULTS: Regression intercept of two-, three-, and six-echo methods were -0.0211, 0.0087, and -0.0062 (P <.001 for all three) without multifrequency modeling and -0.0237 (P <.001), 0.0022, and -0.0007 with multifrequency modeling, respectively. Regression slope of two-, three-, and six-echo methods were 0.8522, 0.8528, and 0.7544 (P <.001 for all three) without multifrequency modeling and 0.9994, 0.9775, and 0.9821 with multifrequency modeling, respectively. Significant deviation of intercept and slope from 0 and 1, respectively, indicated systematic error. Classification accuracy was 82.2%-90.1%, 93.9%-96.3%, and 83.4%-89.6% for two-, three-, and six-echo methods without multifrequency modeling and 88.3%-92.0%, 95.1%-96.3%, and 94.5%-96.3% with multifrequency modeling, respectively, depending on the FF threshold. T2*-corrected (three- and six-echo) multifrequency imaging methods had the overall highest FF estimation and classification accuracy. Among methods without multifrequency modeling, the T2-corrected three-echo method had the highest accuracy. CONCLUSION: Non-T1-weighted MR imaging with T2 correction and multifrequency modeling helps accurately estimate hepatic proton-density FF at 3.0 T.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10100659

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Cited by

See all 290

Metadata

Authors
Yokoo, T., Shiehmorteza, M., Hamilton, G., Wolfson, T., Schroeder, M. E., Middleton, M. S., Bydder, M., Gamst, A. C., Kono, Y., Kuo, A., Patton, H. M., Horgan, S., Lavine, J. E., Schwimmer, J. B., & Sirlin, C. B.
Venue
Radiology
Published
2011-03
Volume
258
Issue
3
Pages
749-759
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1969486929
Cited by
290
References
53
FWCI
13.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T. https://app.cochat.ai/papers/10.1148/radiol.10100659
The paper
Yokoo, T., Shiehmorteza, M., Hamilton, G., Wolfson, T., Schroeder, M. E., Middleton, M. S., Bydder, M., Gamst, A. C., Kono, Y., Kuo, A., Patton, H. M., Horgan, S., Lavine, J. E., Schwimmer, J. B., & Sirlin, C. B. (2011). Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T. Radiology. https://doi.org/10.1148/radiol.10100659

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.