CoChat

Microstructural Brain Abnormalities in Patients with Obsessive-Compulsive Disorder: Diffusion-Tensor MR Imaging Study at 3.0 T

Li, Fei, Huang, Xiaoqi, Yang, Yanchun, Li, Bin, Wu, Qizhu, Zhang, Tijiang, Lui, Su, Kemp, Graham J., Gong, Qiyong · 2011 · Radiology
Cited by 74

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

PURPOSE: To use diffusion-tensor (DT) magnetic resonance (MR) imaging to explore the integrity and connectivity of brain white matter in patients with obsessive-compulsive disorder (OCD) and to correlate DT parameters with clinical measures. MATERIALS AND METHODS: This study was approved by the local ethical committee, and written informed consent was obtained from all participants. DT imaging was performed by using a 3.0-T MR imager in 23 patients with OCD and 23 healthy control subjects matched for age, sex, education level, and handedness. By using voxel-based analysis, fractional anisotropy (FA) and axial and radial diffusivities were compared between patients and control subjects with a two-sample t test and were tested for correlation with symptom severity, as measured by using the Yale-Brown Obsessive-Compulsive Scale and obsessive-compulsive subscale scores, and with illness duration, as measured by using simple regression in statistical parametric mapping program. RESULTS: Compared with control subjects, OCD patients demonstrated significantly increased FA in the genu and body of corpus callosum and white matter of right superior frontal gyrus and corpus callosum; no areas of significantly decreased FA were found. For areas of increased FA, axial diffusivity was higher than that in control subjects, while radial diffusivity was not significantly different. The FA values in the white matter of left middle temporal gyrus in OCD patients correlated positively with clinical measures (r = 0.542, P < .001). CONCLUSION: OCD is associated with axonal microstructural abnormalities within the white matter, which may indicate impaired axonal integrity and increased connectivity. The positive correlation between DT abnormalities and symptom severity suggests that DT imaging may be of clinical value in measuring and following disability in OCD patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.11101971

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 74

Metadata

Authors
Li, F., Huang, X., Yang, Y., Li, B., Wu, Q., Zhang, T., Lui, S., Kemp, G. J., & Gong, Q.
Venue
Radiology
Published
2011-07
Volume
260
Issue
1
Pages
216-223
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2140559573
Cited by
74
References
12
FWCI
9.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microstructural Brain Abnormalities in Patients with Obsessive-Compulsive Disorder: Diffusion-Tensor MR Imaging Study at 3.0 T. https://app.cochat.ai/papers/10.1148/radiol.11101971
The paper
Li, F., Huang, X., Yang, Y., Li, B., Wu, Q., Zhang, T., Lui, S., Kemp, G. J., & Gong, Q. (2011). Microstructural Brain Abnormalities in Patients with Obsessive-Compulsive Disorder: Diffusion-Tensor MR Imaging Study at 3.0 T. Radiology. https://doi.org/10.1148/radiol.11101971

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.