CoChat

MR Imaging of the Small Bowel

Masselli, Gabriele, Gualdi, Gianfranco · 2012 · Radiology
Cited by 188

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Small-bowel radiology has undergone dramatic changes in the past 2 decades. Despite important recent advances in small-bowel endoscopy, radiologic imaging remains important for patients suspected of having or with established small-bowel disease. Cross-sectional imaging techniques (computed tomography and magnetic resonance [MR] imaging), used to investigate both extraluminal abnormalities and intraluminal changes, have gradually replaced barium contrast examinations, which are, however, still used to examine early mucosal disease. MR imaging techniques clearly highlight endoluminal, mural and extramural enteric details and provide vascular and functional information, thereby enhancing the diagnostic value of these techniques in small-bowel diseases. Two MR imaging based techniques are currently utilized: MR enteroclysis and MR enterography. In enteroclysis, enteric contrast material is administered through a nasoenteric tube, whereas in enterography, large volumes of enteric contrast material are administered orally. MR enteroclysis ensures consistently better luminal distention than does MR enterography in both the jejunum and the ileum and more accurately depicts endoluminal abnormalities and early disease, particularly at the level of the jejunal loops. Moreover, MR enteroclysis provides a high level of accuracy in the diagnosis and exclusion of small-bowel inflammatory and neoplastic diseases and can be used for the first radiologic evaluation, while MR enterography may effectively be used to follow up both Crohn disease patients without jejunal disease and in pediatric patients where nasogastric intubation might be a problem. MR enteroclysis may also reveal subtle transition points or an obstruction in the lower small bowel, which may escape detection when more routine methods, including enterography, are used. MR imaging offers detailed morphologic information and functional data of small-bowel diseases and provides reliable evidence of normalcy, thereby allowing the diagnosis of early or subtle structural abnormalities and guiding treatment and decisions in patient care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12111658

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 188

Metadata

Authors
Masselli, G., & Gualdi, G.
Venue
Radiology
Published
2012-08
Volume
264
Issue
2
Pages
333-348
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2120653934
Cited by
188
References
39
FWCI
13.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MR Imaging of the Small Bowel. https://app.cochat.ai/papers/10.1148/radiol.12111658
The paper
Masselli, G., & Gualdi, G. (2012). MR Imaging of the Small Bowel. Radiology. https://doi.org/10.1148/radiol.12111658

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.