Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Prostate Cancer: Feasibility and Preliminary Experience of a Diffusional Kurtosis Model for Detection and Assessment of Aggressiveness of Peripheral Zone Cancer

Rosenkrantz, Andrew B., Sigmund, Eric E., Johnson, Glyn, Babb, James S., Mussi, Thais C., Melamed, Jonathan, Taneja, Samir S., Lee, Vivian S., Jensen, Jens H.·2012·Radiology

Abstract

PURPOSE: To assess the feasibility of diffusional kurtosis (DK) imaging for distinguishing benign from malignant regions, as well as low- from high-grade malignant regions, within the peripheral zone (PZ) of the prostate in comparison with standard diffusion-weighted (DW) imaging. MATERIALS AND METHODS: The institutional review board approved this retrospective HIPAA-compliant study and waived informed consent. Forty-seven patients with prostate cancer underwent 3-T magnetic resonance imaging by using a pelvic phased-array coil and DW imaging (maximum b value, 2000 sec/mm2). Parametric maps were obtained for apparent diffusion coefficient (ADC); the metric DK (K), which represents non-Gaussian diffusion behavior; and corrected diffusion (D) that accounts for this non-Gaussianity. Two radiologists reviewed these maps and measured ADC, D, and K in sextants positive for cancer at biopsy. Data were analyzed by using mixed-model analysis of variance and receiver operating characteristic curves. RESULTS: Seventy sextants exhibited a Gleason score of 6; 51 exhibited a Gleason score of 7 or 8. K was significantly greater in cancerous sextants than in benign PZ (0.96±0.24 vs 0.57±0.07, P<.001), as well as in cancerous sextants with higher rather than lower Gleason score (1.05±0.26 vs 0.89±0.20, P<.001). K showed significantly greater sensitivity for differentiating cancerous sextants from benign PZ than ADC or D (93.3% vs 78.5% and 83.5%, respectively; P<.001), with equal specificity (95.7%, P>.99). K exhibited significantly greater sensitivity for differentiating sextants with low- and high-grade cancer than ADC or D (68.6% vs 51.0% and 49.0%, respectively; P≤.004) but with decreased specificity (70.0% vs 81.4% and 82.9%, respectively; P≤.023). K had significantly greater area under the curve for differentiating sextants with low- and high-grade cancer than ADC (0.70 vs 0.62, P=.010). Relative contrast between cancerous sextants and benign PZ was significantly greater for D or K than ADC (0.25±0.14 and 0.24±0.13, respectively, vs 0.18±0.10; P<.001). CONCLUSION: Preliminary findings suggest increased value for DK imaging compared with standard DW imaging in prostate cancer assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12112290

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 241

Metadata

Authors
Rosenkrantz, A. B., Sigmund, E. E., Johnson, G., Babb, J. S., Mussi, T. C., Melamed, J., Taneja, S. S., Lee, V. S., & Jensen, J. H.
Venue
Radiology
Published
2012-07
Volume
264
Issue
1
Pages
126-135
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2135752648
Cited by
241
References
2
FWCI
13.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prostate Cancer: Feasibility and Preliminary Experience of a Diffusional Kurtosis Model for Detection and Assessment of Aggressiveness of Peripheral Zone Cancer. https://app.cochat.ai/papers/10.1148/radiol.12112290
The paper
Rosenkrantz, A. B., Sigmund, E. E., Johnson, G., Babb, J. S., Mussi, T. C., Melamed, J., Taneja, S. S., Lee, V. S., & Jensen, J. H. (2012). Prostate Cancer: Feasibility and Preliminary Experience of a Diffusional Kurtosis Model for Detection and Assessment of Aggressiveness of Peripheral Zone Cancer. Radiology. https://doi.org/10.1148/radiol.12112290

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.