Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 248

The DOI matches its Crossref record.

Irreversible Electroporation Ablation: Is All the Damage Nonthermal?

Faroja, Mohammad, Ahmed, Muneeb, Appelbaum, Liat, Ben-David, Eliel, Moussa, Marwan, Sosna, Jacob, Nissenbaum, Isaac, Goldberg, S. Nahum · 2013 · Radiology

Abstract

PURPOSE: To determine whether high-dose irreversible electroporation (IRE) ablation induces thermal effects in normal liver tissue. MATERIALS AND METHODS: Animal care and use committee approval was obtained prior to the experiments. IRE ablation (n = 78) was performed by a single four-person team in vivo in 22 porcine livers by applying electric current to two 1.3-cm-diameter circular flat-plate electrodes spaced 1 cm apart. Cardiac-gated IRE pulses (n = 40-360) were systematically applied at varying voltages (1500-2900 V). End temperatures at the ablation zone center were measured and were correlated with ablation time, energy parameters, and resultant treatment effect as determined at gross pathologic and histopathologic examination. Temperatures were then monitored at the center and periphery of four ablations created by using a four-electrode IRE array (3000 V, 90 pulses per electrode pair). Data were analyzed by using multivariate analysis of variance with multiple comparisons and/or paired t tests and regression analysis, as appropriate. RESULTS: Temperature rose above the 34°C baseline after IRE in all flat-plate experiments and correlated linearly (R(2) = 0.39) with IRE "energy dose" (product of voltage and number of pulses) and more tightly in univariate analysis with both voltage and number of pulses. Thus, mean temperatures as high as 86°C ± 3 (standard deviation) were seen for 2500 V and 270 pulses. Ablations of 90 pulses or more at 2500 V produced temperatures of 50°C or greater and classic gross and histopathologic findings of thermal coagulation (pyknotic nuclei and streaming cytoplasm). For lower IRE doses (ie, 2100 V, 90 pulses), temperatures remained below 45°C, and only IRE-associated pathologic findings (ie, swollen sinusoids, dehydrated cells, and hemorrhagic infiltrate) were seen. For the four-electrode arrays, temperatures measured 54.2°C ± 6.1 at the electrode surfaces and 38.6°C ± 3.2 at the ablation zone margin. CONCLUSION: In some conditions of high intensity, IRE can produce sufficient heating to induce "white zone" thermal coagulation. While this can be useful in some settings to increase tumor destruction, further characterization of the thermal profile created with clinical electrodes and energy parameters is therefore needed to better understand the best ways to avoid unintended damage when ablating near thermally sensitive critical structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12120609

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 248

Metadata

Authors
Faroja, M., Ahmed, M., Appelbaum, L., Ben-David, E., Moussa, M., Sosna, J., Nissenbaum, I., & Goldberg, S. N.
Venue
Radiology
Published
2013-02
Volume
266
Issue
2
Pages
462-470
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2126573497
Cited by
248
References
0
FWCI
15.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Irreversible Electroporation Ablation: Is All the Damage Nonthermal? https://app.cochat.ai/papers/10.1148/radiol.12120609
The paper
Faroja, M., Ahmed, M., Appelbaum, L., Ben-David, E., Moussa, M., Sosna, J., Nissenbaum, I., & Goldberg, S. N. (2013). Irreversible Electroporation Ablation: Is All the Damage Nonthermal? Radiology. https://doi.org/10.1148/radiol.12120609

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.