Intravenous Contrast Material–induced Nephropathy: Causal or Coincident Phenomenon?

Open access
McDonald, Robert J., McDonald, Jennifer S., Bida, John P., Carter, Rickey E., Fleming, Chad J., Misra, Sanjay, Williamson, Eric E., Kallmes, David F.·2013·Radiology

Abstract

PURPOSE: To determine the causal association and effect of intravenous iodinated contrast material exposure on the incidence of acute kidney injury (AKI), also known as contrast material-induced nephropathy (CIN). MATERIALS AND METHODS: This retrospective study was approved by an institutional review board and was HIPAA compliant. Informed consent was waived. All contrast material-enhanced (contrast group) and unenhanced (noncontrast group) abdominal, pelvic, and thoracic CT scans from 2000 to 2010 were identified at a single facility. Scan recipients were sorted into low- (<1.5 mg/dL), medium- (1.5-2.0 mg/dL), and high-risk (>2.0 mg/dL) subgroups of presumed risk for CIN by using baseline serum creatinine (SCr) level. The incidence of AKI (SCr ≥ 0.5 mg/dL above baseline) was compared between contrast and noncontrast groups after propensity score adjustment by stratification, 1:1 matching, inverse weighting, and weighting by the odds methods to reduce intergroup selection bias. Counterfactual analysis was used to evaluate the causal relation between contrast material exposure and AKI by evaluating patients who underwent contrast-enhanced and unenhanced CT scans during the study period with the McNemar test. RESULTS: A total of 157,140 scans among 53,439 unique patients associated with 1,510,001 SCr values were identified. AKI risk was not significantly different between contrast and noncontrast groups in any risk subgroup after propensity score adjustment by using reported risk factors of CIN (low risk: odds ratio [OR], 0.93; 95% confidence interval [CI]: 0.76, 1.13; P = .47; medium risk: odds ratio, 0.97; 95% CI: 0.81, 1.16; P = .76; high risk: OR, 0.91; 95% CI: 0.66, 1.24; P = .58). Counterfactual analysis revealed no significant difference in AKI incidence between enhanced and unenhanced CT scans in the same patient (McNemar test: χ(2) = 0.63, P = .43) (OR = 0.92; 95% CI: 0.75, 1.13; P = .46). CONCLUSION: Following adjustment for presumed risk factors, the incidence of CIN was not significantly different from contrast material-independent AKI. These two phenomena were clinically indistinguishable with established SCr-defined criteria, suggesting that intravenous iodinated contrast media may not be the causative agent in diminished renal function after contrast material administration. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12121823/-/DC1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12121823

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 386

Metadata

Authors
McDonald, R. J., McDonald, J. S., Bida, J. P., Carter, R. E., Fleming, C. J., Misra, S., Williamson, E. E., & Kallmes, D. F.
Venue
Radiology
Published
2013-04
Volume
267
Issue
1
Pages
106-118
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2110630600
Cited by
386
References
42
FWCI
27.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intravenous Contrast Material–induced Nephropathy: Causal or Coincident Phenomenon? https://app.cochat.ai/papers/10.1148/radiol.12121823
The paper
McDonald, R. J., McDonald, J. S., Bida, J. P., Carter, R. E., Fleming, C. J., Misra, S., Williamson, E. E., & Kallmes, D. F. (2013). Intravenous Contrast Material–induced Nephropathy: Causal or Coincident Phenomenon? Radiology. https://doi.org/10.1148/radiol.12121823

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.