Clinical Impact of PET/MR Imaging in Patients with Cancer Undergoing Same-Day PET/CT: Initial Experience in 134 Patients—A Hypothesis-generating Exploratory Study
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare the clinical impact of combined positron emission tomography (PET) and magnetic resonance (MR) imaging to that of combined PET and computed tomography (CT) performed on the same day in patients with cancer. MATERIALS AND METHODS: This HIPAA-compliant retrospective study was approved by the institutional review board. Patients gave written informed consent for study enrollment, including the possibility to use their imaging and clinical data in future evaluations. A total of 134 patients with cancer with a non-central nervous system primary neoplasm underwent same-day fluorodeoxyglucose (FDG) PET/CT and FDG PET/MR imaging. PET/CT and PET/MR studies were independently interpreted by teams of radiologists and nuclear medicine physicians. Four readers, divided into two teams composed of one radiologist and one nuclear medicine physician each, read all 134 studies. The referring physician classified discordance between PET/CT and PET/MR observations either as findings affecting clinical management or as findings not affecting clinical management. Data were compared with the χ(2) test. RESULTS: Findings affecting clinical management were noted for PET/CT studies but not for PET/MR studies in two (1.5%) of 134 patients and for PET/MR studies but not for PET/CT studies in 24 (17.9%) of 134 patients. The discrepancies between findings affecting clinical management detected with PET/MR imaging over those detected with PET/CT were significant (P < .001). CONCLUSION: In these patients, PET/MR imaging alone contributed to clinical management more often than did PET/CT alone. PET/MR imaging provides information that affects the care of patients with cancer and is unavailable from PET/CT. Online supplemental material is available for this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534
TNM Classification of Malignant Tumours
(1987) · Springer eBooks · doi:10.1007/978-3-642-82982-6 · Cited by 16,049
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416 · cited 1×
“enable more accurate TNM staging than either CT or PET alone (12,13).”
BackgroundFDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Boellaard, R., O’Doherty, M. J., Weber, W. A., Mottaghy, F. M., Lonsdale, M. N., Stroobants, S. G., Oyen, W. J. G., Kotzerke, J., Hoekstra, O. S., Pruim, J., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1297-4 · Cited by 1,326
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Brown, G., Richards, C. J., Bourne, M. W., Newcombe, R. G., Radcliffe, A. G., Dallimore, N. S., & Williams, G. T. (2003) · Radiology · doi:10.1148/radiol.2272011747 · Cited by 872
Non–Small Cell Lung Cancer: Dual-Modality PET/CT in Preoperative Staging
Antoch, G., Stattaus, J., Nemat, A. T., Marnitz, S., Beyer, T., Kuehl, H., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2003) · Radiology · doi:10.1148/radiol.2292021598 · Cited by 540 · cited 1×
“enable more accurate TNM staging than either CT or PET alone (12,13).”
Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., Nekolla, S. G., Ziegler, S., Ganter, C., Rummeny, E. J., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.098608 · Cited by 508 · cited 1×
“On the other hand, our approach is different from that used in other studies, such as the study by Drzezga and colleagues (35), who focused only on the detectability of metabolically active lesions demonstrating the noninferiority of PET/MR detection when compared with PET/CT detection.”
ResultKayani, I., Bomanji, J. B., Groves, A., Conway, G., Gacinovic, S., Win, T., Dickson, J., Caplin, M., & Ell, P. J. (2008) · Cancer · doi:10.1002/cncr.23469 · Cited by 477
Duffy, J. P., Vardanian, A., Benjamin, E., Watson, M., Farmer, D. G., Ghobrial, R. M., Lipshutz, G., Yersiz, H., Lu, D. S. K., Lassman, C., et al. (2007) · Annals of Surgery · doi:10.1097/sla.0b013e318148c704 · Cited by 445
Whole-Body Diffusion-weighted MR Imaging in Cancer: Current Status and Research Directions
Padhani, A. R., Koh, D.-M., & Collins, D. J. (2011) · Radiology · doi:10.1148/radiol.11110474 · Cited by 336
Hepatic Metastases: Diffusion-weighted Sensitivity-encoding versus SPIO-enhanced MR Imaging
Nasu, K., Kuroki, Y., Nawano, S., Kuroki, S., Tsukamoto, T., Yamamoto, S., Motoori, K., & Ueda, T. (2006) · Radiology · doi:10.1148/radiol.2383041384 · Cited by 322
Park, J.-W., Kim, J. H., Kim, S. K., Kang, K. W., Park, K. W., Choi, J.-I., Lee, W. J., Kim, C.-M., & Nam, B. H. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.055087 · Cited by 287
Hybrid PET/MRI of Intracranial Masses: Initial Experiences and Comparison to PET/CT
Boss, A., Bisdas, S., Kolb, A., Hofmann, M., Ernemann, U., Claussen, C. D., Pfannenberg, C., Pichler, B. J., Reimold, M., & Stegger, L. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.074773 · Cited by 271 · cited 2×
“These MR features, combined with the metabolic information from PET, suggest the potential for PET/MR imaging to have an extensive effect on patient care (2,4).”
BackgroundJerusalem, G., Beguin, Y., Najjar, F., Hustinx, R., Fassotte, M. F., Rigo, P., & Fillet, G. (2001) · Annals of Oncology · doi:10.1023/a:1011169332265 · Cited by 268
Tsukamoto, N., Kojima, M., Hasegawa, M., Oriuchi, N., Matsushima, T., Yokohama, A., Saitoh, T., Handa, H., Endo, K., & Murakami, H. (2007) · Cancer · doi:10.1002/cncr.22807 · Cited by 193
Cheng, G., Torigian, D. A., Zhuang, H., & Alavi, A. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2343-9 · Cited by 164
A look ahead: PET/MR versus PET/CT
von Schulthess, G. K., & Schlemmer, H.-P. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0940-9 · Cited by 120 · cited 3×
“A total of 60 patients were excluded from this study: Twenty were excluded because fluorine 18 choline was injected; 17 were excluded because oncologic evaluation was not performed; 17 were excluded For more than a decade, combined positron emission tomography (PET) and computed tomography (CT) hybrid scanners have be…”
BackgroundLymph node size does not correlate with the presence of prostate cancer metastasis
Tiguert, R., Gheiler, E. L., Tefilli, M. V., Oskanian, P., Banerjee, M., Grignon, D. J., Sakr, W., Pontes, J. E., & Wood, D. P. (1999) · Urology · doi:10.1016/s0090-4295(98)00518-4 · Cited by 116
Holzapfel, K., Bruegel, M., Eiber, M., Ganter, C., Schuster, T., Heinrich, P., Rummeny, E. J., & Gaa, J. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.05.014 · Cited by 116 · cited 1×
“0 3 1023mm2/sec or less were deemed malignant (6,8).”
BackgroundComparison of integrated whole-body [11C]choline PET/MR with PET/CT in patients with prostate cancer
Souvatzoglou, M., Eiber, M. J., Takei, T., Fürst, S., Maurer, T., Gaertner, F. C., Geinitz, H., Drzezga, A. E., Ziegler, S. I., Nekolla, S. G., et al. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2467-y · Cited by 111 · cited 1×
“Our experience is in agreement with that of Souvatzoglou and colleagues (31) who found carbon 11 choline PET/MR imaging performed better than carbon 11 choline PET/CT in the anatomic allocation of metastatic bony lesions from prostate cancer.”
ResultDetection Rate, Location, and Size of Pulmonary Nodules in Trimodality PET/CT-MR
Stolzmann, P., Veit‐Haibach, P., Chuck, N. C., Rossi, C., Frauenfelder, T., Alkadhi, H., von Schulthess, G. K., & Boss, A. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e31826f2de9 · Cited by 110 · cited 1×
“This is similar to the approach of Stolzmann and colleagues (34), who used a trimodality PET/CT MR imager in 40 consecutive patients to look for lung nodules.”
Daniels, I. R., Fisher, S. E., Heald, R. J., & Moran, B. J. (2007) · Colorectal Disease · doi:10.1111/j.1463-1318.2006.01116.x · Cited by 99
Assessment of dual-time-point 18F-FDG-PET imaging for pulmonary lesions
Laffon, É., de Clermont-Gallerande, H., Bégueret, H., Vernejoux, J.-M., Thumerel, M., Marthan, R., & Ducassou, D. (2009) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32832bdcac · Cited by 52
Sharma, P., Kumar, R., Singh, H., Jeph, S., Sharma, D. N., Bal, C. S., & Malhotra, A. (2012) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e31824d24fa · Cited by 45
Imaging of Lymphoma of the Musculoskeletal System
Hwang, S. (2008) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.03.008 · Cited by 42
Yoo, H. J., Lee, J. M., Lee, M. W., Kim, S. J., Lee, J. Y., Han, J. K., & Choi, B. I. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181768d96 · Cited by 37 · cited 1×
“In the pelvis, PET/CT has intrinsic limitations that can be reduced by using proper techniques, including bladder catheterization, but cannot be Among these factors, lesion size plays an important role: Lung nodules smaller than 6–7 mm are difficult to appreciate on MR images due to their relatively low signal intensi…”
BackgroundSpectrum of PET–CT pelvic pitfalls in patients with gynecologic malignancies
Gorospe, L., Jover-Díaz, R., & Vicente-Bártulos, A. (2012) · Abdominal Imaging · doi:10.1007/s00261-012-9867-5 · Cited by 12
Cited by
Nuclear medicine and molecular imaging advances in the 21st century
Vaz, S. C., Oliveira, F., Herrmann, K., & Veit-Haibach, P. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20200095 · Cited by 86
Metadata
- Authors
- Catalano, O. A., Rosen, B. R., Sahani, D. V., Hahn, P. F., Guimaraes, A. R., Vangel, M. G., Nicolai, E., Soricelli, A., & Salvatore, M.
- Venue
- Radiology
- Published
- 2013-12
- Volume
- 269
- Issue
- 3
- Pages
- 857-869
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2153517574
- Cited by
- 164
- References
- 29
- FWCI
- 15.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.