Simultaneous Whole-Body PET/MR Imaging in Comparison to PET/CT in Pediatric Oncology: Initial Results
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare positron emission tomography (PET)/magnetic resonance (MR) imaging and PET/computed tomography (CT) for lesion detection and interpretation, quantification of fluorine 18 ((18)F) fluorodeoxyglucose (FDG) uptake, and accuracy of MR-based PET attenuation correction in pediatric patients with solid tumors. Materials and Methods This prospective study had local ethics committee and German Federal Institute for Drugs and Medical Devices approval. Written informed consent was obtained from all patients and legal guardians. Twenty whole-body (18)F-FDG PET/CT and (18)F-FDG PET/MR examinations were performed in 18 pediatric patients (median age, 14 years; range, 11-17 years). (18)F-FDG PET/CT and (18)F-FDG PET/MR data were acquired sequentially on the same day for all patients. PET standardized uptake values (SUVs) were quantified with volume of interest measurements in lesions and healthy tissues. MR-based PET attenuation correction was compared with CT-derived attenuation maps (µ-maps). Lesion detection was assessed with separate reading of PET/CT and PET/MR data. Estimates of radiation dose were derived from the applied doses of (18)F-FDG and CT protocol parameters. Descriptive statistical analyses were performed to report correlation coefficients and relative deviations for comparison of SUVs, rates of lesion detection, and percentage reductions in radiation dose. RESULTS: PET SUVs showed strong correlations between PET of PET/CT (PETCT) and PET of PET/MR (PETMR) (r > 0.85 for most tissues). Apart from drawbacks of MR-based PET attenuation correction in osseous structures and lungs, similar SUVs were found on PET images corrected with CT-based µ-maps (13.1% deviation of SUVs for bone marrow and <5% deviation for other tissues). Lesion detection rate with PET/MR imaging was equivalent to that with PET/CT (61 areas of focal uptake on PETMR images vs 62 areas on PETCT images). Advantages of PET/MR were observed especially in soft-tissue regions. Furthermore, PET/MR offered significant dose reduction (73%) compared with PET/CT. CONCLUSION: Pediatric oncologic PET/MR is technically feasible, showing satisfactory performance for PET quantification with SUVs similar to those of PET/CT. Compared with PET/CT, PET/MR demonstrates equivalent lesion detection rates while offering markedly reduced radiation exposure. Thus, PET/MR is a promising modality for the clinical work-up of pediatric malignancies. Online supplemental material is available for this article.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Systematic underestimation of SUV in bone tissue or lesions close to the bone of >10% compared to PET/CT has been described [60,62], whereas SUV differences were <5% in other normal tissues [60].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [60]
In the citing paper
“However, several sources of error exist, including extracorporeal components such as headphones, dense hair or MR coils [59], incorrect attenuation correction factors for bone and lung tissue [60], incorrect segmentation of such compartments, and MR image truncation [61].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [60]
In the citing paper
“However, systematically different normal organ SUVs have been reported for [18F]FDG as well, which most likely result from MR-AC inaccuracies [60,65,66].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [60]
Citations
Cites
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
American Association of Physicists in Medicine
(1973) · Radiology · doi:10.1148/106.3.717b · Cited by 732
Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., Nekolla, S. G., Ziegler, S., Ganter, C., Rummeny, E. J., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.098608 · Cited by 508
Daldrup-Link, H. E., Franzius, C., Link, T. M., Laukamp, D., Sciuk, J., Jürgens, H., Schober, O., & Rummeny, E. J. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.1.1770229 · Cited by 444
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
Chawla, S. C., Federman, N., Zhang, D., Nagata, K., Nuthakki, S., McNitt-Gray, M., & Boechat, M. I. (2010) · Pediatric Radiology · doi:10.1007/s00247-009-1434-z · Cited by 218
Guidelines for 18F-FDG PET and PET-CT imaging in paediatric oncology
Stauss, J., Franzius, C., Pfluger, T., Juergens, K. U., Biassoni, L., Begent, J., Kluge, R., Amthauer, H., Voelker, T., Højgaard, L., et al. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0826-x · Cited by 190
Review of functional/anatomical imaging in oncology
Histed, S. N., Lindenberg, M. L., Mena, E., Turkbey, B., Choyke, P. L., & Kurdziel, K. A. (2012) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32834ec8a5 · Cited by 175
Pulmonary Lesion Assessment: Comparison of Whole-Body Hybrid MR/PET and PET/CT Imaging—Pilot Study
Schwenzer, N. F., Schraml, C., Müller, M., Brendle, C., Sauter, A. W., Spengler, W., Pfannenberg, A. C., Claussen, C. D., & Schmidt, H. (2012) · Radiology · doi:10.1148/radiol.12111942 · Cited by 160
Self-citation
Research works printed but not linked: 3
- Franzius C, 2010, Q J Nucl Med Mol Imaging, 54, 401
- Knopp MV, 2003, Mol Cancer Ther, 2, 419
- Bongartz G, 2004, Luxenbourg: European Commission
Cited by
Items 101–200 of 215
Clinical Applications of Pediatric Positron Emission Tomography-Magnetic Resonance Imaging
Teixeira, S. R., Martinez‐Rios, C., Hu, L., & Bangert, B. A. (2014) · Seminars in Roentgenology · doi:10.1053/j.ro.2014.10.002 · Cited by 11
Simon, T., Thole-Kliesch, T. M., Castelli, S., Timmermann, B., Jazmati, D., Schwarz, R., Fuchs, J., Warmann, S. W., Hubertus, J., Schmidt, M. C., et al. (2025) · Klinische Pädiatrie · doi:10.1055/a-2556-4302 · Cited by 14
“Comparison with MRI or, if available, PET-MRI is recommended, since bone marrow often intensively absorbs [ 18 F]FDG after recovery from chemotherapy, which may be misinterpreted as persistent or even progressive bone marrow infiltration [33].”
Self-citationPET/MR Imaging for Chest Diseases
Yoon, S. H., Goo, J. M., Lee, S. M., Park, C. M., & Cheon, G. J. (2015) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2015.01.008 · Cited by 11
PET/MRI: A luxury or a necessity?
Carreras-Delgado, J. L., Pérez-Dueñas, V., Riola-Parada, C., & García‐Cañamaque, L. (2016) · Revista Española de Medicina Nuclear e Imagen Molecular (English Edition) · doi:10.1016/j.remnie.2016.07.002 · Cited by 11
(18F)-FDG-PET/MRI of unicentric retroperitoneal Castleman disease in a pediatric patient
Rassouli, N., Obmann, V. C., Sandhaus, L. M., & Herrmann, K. A. (2018) · Clinical Imaging · doi:10.1016/j.clinimag.2018.03.010 · Cited by 10
PET-MRI: clinical application of the new hybrid technology
Tudisca, C., Nasoodi, A., & Fraioli, F. (2015) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000312 · Cited by 10
Practical Considerations for Clinical PET/MR Imaging
Galgano, S. J., Viets, Z., Fowler, K. J., Gore, L., Thomas, J. V., McNamara, M. M., & McConathy, J. (2017) · PET Clinics · doi:10.1016/j.cpet.2017.09.002 · Cited by 11
Storz, C., Bares, R., Ebinger, M., Handgretinger, R., Tsiflikas, I., & Schäfer, J. F. (2019) · BMC Medical Imaging · doi:10.1186/s12880-019-0372-y · Cited by 10
Self-citationChodyla, M.-K., Barbato, F., Dirksen, U., Kirchner, J., Schaarschmidt, B. M., Schweiger, B., Forsting, M., Herrmann, K., Umutlu, L., & Grueneisen, J. S. (2022) · Diagnostics · doi:10.3390/diagnostics12102278 · Cited by 9
“Especially, for the frequently young patient population with Ewing sarcomas, these integrated imaging systems could be of value, as they provide a notable reduction in ionizing radiation when compared to PET/CT scanners due to the omission of the CT-component [11,12].”
BackgroundPeng, L., Liao, Y., Zhou, R., Zhong, Y., Jiang, H., Wang, J., Fu, Y., Xue, L., Zhang, X., Sun, M., et al. (2023) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-023-06273-6 · Cited by 13
“Currently, some studies have been conducted on the diagnostic values of PET/MRI for local regions of the human body [14, 15]; it is still lack of research involved in investigating PET/MRI as a general cancer detection modality for the whole body, especially based on a large population.”
Uslu, L., Atay, L. Ö., Karadeniz, C., Akdemir, Ü. Ö., Pınarlı, F. G., Aydos, U., Okur, A., Kaya, Z., Samancı, C., & Karabacak, N. İ. (2019) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0000000000001465 · Cited by 10
One-stop local and whole-body staging of children with cancer
Daldrup-Link, H. E., Theruvath, A. J., Baratto, L., & Hawk, K. E. (2021) · Pediatric Radiology · doi:10.1007/s00247-021-05076-x · Cited by 9
“Initial experiences testify to excellent sensitivity of (18)F-FDG PET/MRI for whole-body staging of people with sarcomas [13, 14, 38, 44].”
BackgroundQueiroz, M. A., Barbosa, F. D. G., Buchpiguel, C. A., & Cerri, G. G. (2018) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.64.01.71 · Cited by 151
[18F]FDG PET/MRI in children suffering from lymphoma: does MRI contrast media make a difference?
Jannusch, K., Morawitz, J., Schweiger, B., Weiss, D. A., Schimmöller, L., Minko, P., Herrmann, K., Fendler, W. P., Quick, H. H., Antoch, G., et al. (2023) · European Radiology · doi:10.1007/s00330-023-09840-5 · Cited by 8
“Nonetheless, both modalities come with repetitive radiation exposure and an increasing risk of future secondary malignancies [6–9].”
BackgroundLyons, K. A., Seghers, V. J., Williams, J. L., Sorensen, J. I. L., Paldino, M. J., Krishnamurthy, R., & ROHREN, E. M. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.14231 · Cited by 10
“Thus far to our knowledge, only one study (n = 20) comparing PET/MRI with PET/CT assessments of children has been published [13].”
BackgroundInfluentialLower Gastrointestinal Tract Applications of PET/Computed Tomography and PET/MR Imaging
Catalano, O. A., Kilcoyne, A., Signore, A., Mahmood, U., & Rosen, B. R. (2018) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2018.05.001 · Cited by 8
Imaging features of extranodal involvement in paediatric Hodgkin lymphoma
Spijkers, S., Littooij, A. S., Humphries, P. D., Lam, M. G. E. H., & Nievelstein, R. A. J. (2018) · Pediatric Radiology · doi:10.1007/s00247-018-4280-z · Cited by 8
PET/MR Imaging in Musculoskeletal Precision Imaging - Third wave after X-Ray and MR
Hancin, E. C., Borja, A. J., Nikpanah, M., Raynor, W., Haldar, D., Werner, T. J., Morris, M. A., Saboury, B., Alavi, A. A., & Gholamrezanezhad, A. (2020) · PET Clinics · doi:10.1016/j.cpet.2020.06.001 · Cited by 8
Prognostic Value of Hybrid PET/MR Imaging in Patients with Differentiated Thyroid Cancer
Piscopo, L., Nappi, C., Volpe, F., Romeo, V., Nicolai, E., Gallicchio, R., Giordano, A., Storto, G., Pace, L., Cavaliere, C., et al. (2022) · Cancers · doi:10.3390/cancers14122958 · Cited by 8
Urtiaga, S., Souvannanorath, S., Leboucq, N., Haouy, S., Rivier, F., Roubertie, A., & Meyer, P. (2022) · European Journal of Paediatric Neurology · doi:10.1016/j.ejpn.2022.07.002 · Cited by 8
Pediatric Nuclear Medicine and its Development as a Specialty
Bielsa, I. R. (2017) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2016.10.004 · Cited by 8
Up-to-date review of nuclear medicine applications in pediatric thoracic imaging
Kwatra, N. S., Grant, F. D., Lim, R., & Lee, E. Y. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.04.007 · Cited by 7
Crimì, F., Varotto, A., Orsatti, G., Lacognata, C. S., Cecchin, D., Frigo, A. C., Zucchetta, P., Stramare, R., & Pomerri, F. (2019) · Clinical Radiology · doi:10.1016/j.crad.2019.10.024 · Cited by 7
Bisdas, S., la Fougère, C. J., & Ernemann, U. (2015) · Clinical Neuroradiology · doi:10.1007/s00062-015-0427-6 · Cited by 7
Practical Considerations for Clinical PET/MR Imaging
Galgano, S. J., Viets, Z., Fowler, K. J., Gore, L., Thomas, J. V., McNamara, M. M., & McConathy, J. (2017) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2016.12.006 · Cited by 8
Whole-Body MRI in Pediatric Oncology
Nievelstein, R. A. J., & Littooij, A. S. (2019) · Pediatric oncology · doi:10.1007/978-3-030-03777-2_7 · Cited by 7
Simultane Ganzkörper-PET-MRT in der pädiatrischen Onkologie
Gatidis, S., Gückel, B., la Fougère, C. J., Schmitt, J., & Schäfer, J. F. (2016) · Der Radiologe · doi:10.1007/s00117-016-0122-x · Cited by 7
Self-citationPediatric Anesthesia Outside the Operating Room
Setiawan, C. T., & Landrigan-Ossar, M. F. (2020) · Anesthesiology Clinics · doi:10.1016/j.anclin.2020.06.003 · Cited by 7
Spijkers, S., Littooij, A. S., Beishuizen, A., Lam, M. G. E. H., & Nievelstein, R. A. J. (2023) · EJC Paediatric Oncology · doi:10.1016/j.ejcped.2023.100016 · Cited by 6
Pugmire, B. S., Guimarães, A. R., Lim, R., Friedmann, A. M., Huang, M., Ebb, D. H., Weinstein, H. J., Catalano, O. A., Mahmood, U., Catana, C., et al. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i3.322 · Cited by 6
Promoting Collaborations Between Radiologists and Scientists
Yu, J. J., Spieler, B. M., Chan, T. L., Johnson, E., Gulani, V., Sandler, K. L., Narayana, P. A., Mar, W. A., Brian, J. M., Ng, C. K., et al. (2017) · Academic Radiology · doi:10.1016/j.acra.2017.05.020 · Cited by 6
Bildgebende Diagnostik bei Skelettmetastasen
Kintzelé, L., & Weber, M. D. (2017) · Der Radiologe · doi:10.1007/s00117-016-0205-8 · Cited by 6
Asmundo, L., Furtado, F., Delaney, F. T., Mojtahed, A., Hajati, A., Esfahani, S. A., Kambadakone, A. R., Blaszkowsky, L. S., Clark, J. W., Ryan, D. P., et al. (2025) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-025-07333-9 · Cited by 5
“Future multi-center studies with larger cohorts, additional PET tracers, and comprehensive histopathological confirmation would further strengthen these conclusions. imaging studies and minimizing patient exposure to radiation from stand-alone FDG-PET or CT [29, 30].”
Pediatric PET/MRI: Imaging Techniques, Indications, and Clinical Implementation
Gatidis, S., Ponisio, M. R., Borgwardt, L., Cain, T. M., Francis, P., Hamdi, M., Johnson, G. B., Kurch, L., Laforest, R. A., Lim, R., et al. (2025) · Radiographics · doi:10.1148/rg.240105 · Cited by 8
Self-citation18Fluorine-fluorodeoxyglucose PET/CT Imaging in Childhood Malignancies
Bıçakcı, N., & Elli, M. (2021) · Molecular Imaging and Radionuclide Therapy · doi:10.4274/mirt.galenos.2020.64436 · Cited by 5
“Dose reductions of up to 73% have been reported when performing PET/MRI instead of (18)F-FDG PET/CT because of lack of the CT component, and decreasing the amount of PET tracer administered (because of longer imaging times in PET/MRI) could further reduce the radiation dose (63).”
BackgroundSchäfer, J. F., Gassenmaier, S., Warmann, S. W., Urla, C., Frauenfeld, L., Flaadt, T., Chaika, M., Esser, M., Tsiflikas, I., Timmermann, B., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12237297 · Cited by 5
“PET/MRI combines both advantages with low radiation exposure [53].”
BackgroundSelf-citationPET/MRI and PET/CT: is there room for both at the top of the food chain?
Kuwert, T., & Ritt, P. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3246-8 · Cited by 5
Pediatric Imaging Using PET/MR Imaging
Giraudo, C., Carraro, S., Zucchetta, P., & Cecchin, D. (2023) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2023.06.001 · Cited by 7
PET/RM: ¿un lujo o una necesidad?
Carreras-Delgado, J. L., Pérez-Dueñas, V., Riola-Parada, C., & García‐Cañamaque, L. (2016) · Revista Española de Medicina Nuclear e Imagen Molecular · doi:10.1016/j.remn.2016.05.007 · Cited by 7
Imaging of Complications After Limb Prostheses Implantation in Children with Bone Tumors
Iwanowska, B., Brągoszewska, H., Mądzik, J., Szkudlińska-Pawlak, S., Kopyś-Wiszniewska, I., Jastrzębska, M., Kowalska, B., Uliasz, M., & Bekiesińska‐Figatowska, M. (2017) · Polish Journal of Radiology · doi:10.12659/pjr.900644 · Cited by 5
Ngô, T. M., Vágner, A., Nagy, G., Ország, G., Nagy, T., Szoboszlai, Z., Csikos, C., Váradi, B., Trencsényi, G., Tircsó, G., et al. (2025) · Pathology & Oncology Research · doi:10.3389/pore.2025.1611999 · Cited by 5
Aydos, U., Balcı, E., Ateş, S. G., Akdemir, Ü., Karadeniz, C., & Atay, L. (2022) · Turkish Journal of Medical Sciences · doi:10.55730/1300-0144.5584 · Cited by 3
“Radiation exposure can be significantly reduced by up to 70% by replacing CT with MRI using hybrid PET/MRI scanners [11].”
BackgroundCarluccio, G., Ding, Y., Logan, J., & Collins, C. M. (2016) · Medical Physics · doi:10.1002/mp.12046 · Cited by 4
“(7)), perfusion is kept constant and equal to W0 (not temperature dependent as in Eq.”
BackgroundInfluentialEmerging Roles of PET/MR in the Pediatric Hospital
Saade-Lemus, S. M., Teixeira, S. R., Vossough, A., Servaes, S. E., & States, L. J. (2020) · PET Clinics · doi:10.1016/j.cpet.2020.03.005 · Cited by 4
Nensa, F., Forsting, M., & Wetter, A. (2016) · Der Urologe · doi:10.1007/s00120-016-0045-1 · Cited by 3
“Dies ist insbesondere für pädiatrische Patienten von Vorteil, da die Anwendung ionisierender Strahlung im Kindesalter natürlich besonders sorgfältig abgewogen werden muss [7].”
The reduction of 176 Lu background in Lu-based PET scanners using optimized classification
Wang, Q., Mikhaylova, E., Baikejiang, R., & Cherry, S. R. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aba088 · Cited by 3
Giraudo, C., Carraro, E., Cavallaro, E. C., Zuliani, M., Gotsyak, L. S., Massano, D., Modugno, A., Mussolin, L., Biffi, A., Cecchin, D., et al. (2023) · Diagnostics · doi:10.3390/diagnostics13030565 · Cited by 3
Skawran, S., Sartoretti, T., Gennari, A. G., Schwyzer, M., Sartoretti, E., Treyer, V., Maurer, A. B., Huellner, M. W., Waelti, S. L., & Messerli, M. (2023) · British Journal of Radiology · doi:10.1259/bjr.20220482 · Cited by 3
Cox, C. P. W., Brabander, T., Vegt, E., de Lussanet, Q. G., Graven, L. H., Verburg, F. A., & Segbers, M. (2024) · EJNMMI Physics · doi:10.1186/s40658-024-00629-z · Cited by 3
Akram, M. S. H., Obata, T., Nishikido, F., & Yamaya, T. (2022) · Medical Physics · doi:10.1002/mp.15588 · Cited by 3
Daldrup-Link, H. E., & Gambhir, S. S. (2014) · Springer eBooks · doi:10.1007/978-1-4614-9551-2_25 · Cited by 4
Franc, B. L., & Daldrup-Link, H. E. (2019) · Pediatric oncology · doi:10.1007/978-3-030-03777-2_19 · Cited by 3
The three futures of bone marrow imaging: a radiologist’s guide
Martín‐Noguerol, T., Casado-Verdugo, O. L., Garcia, B. A. D. S., Aguilar, G. H., Santos‐Armentia, E., Vilanova, J. C., & Luna, A. (2025) · British Journal of Radiology · doi:10.1093/bjr/tqaf262 · Cited by 3
Saade-Lemus, S. M., Nevo, E., Soliman, I., Otero, H. J., Magee, R., Drum, E. T., & States, L. J. (2020) · Pediatric Radiology · doi:10.1007/s00247-019-04578-z · Cited by 2
“PET/MR has been shown to have up to 70% less radiation than PET/CT [11] at some institutions, with others reporting a 30% reduction.”
BackgroundMethodDiagnostic Applications of Nuclear Medicine: Pediatric Cancers
Pfluger, T., Ciarmiello, A., Giovacchini, G., Montravers, F., Pointe, H. D. L., Landman‐Parker, J., Meniconi, M., & Franzius, C. (2016) · Springer eBooks · doi:10.1007/978-3-319-26067-9_25-1 · Cited by 2
Yang, L., Wu, Y., Tang, H., Zhao, J., Zhao, D., Yang, S., & Wang, Q. (2018) · OncoTargets and Therapy · doi:10.2147/ott.s155033 · Cited by 2
“Positron emission tomography coupled with computed tomography (PET-CT) has long been a reference imaging tool for the diagnosis and staging of tumors,(16) particularly in cases where the metastatic tumors of the primary lesion were unknown.(17) There are some studies confirming that metabolic tumor volume (MTV) and to…”
Bone Neoplasms: Osteosarcoma and Ewing Sarcoma
Degnan, A. J., El-Ali, A. M., Davis, J. C., Gillman, J. A. M., & Khanna, G. (2022) · Evidence-based imaging · doi:10.1007/978-3-030-38095-3_72-1 · Cited by 2
Kombinierte Positronenemissions-Magnetresonanztomographie (PET/MRT) bei Kindern und Jugendlichen
Schäfer, J. F., Tsiflikas, I., Esser, M., Dittmann, H., Bender, B., & Gatidis, S. (2020) · Monatsschrift Kinderheilkunde · doi:10.1007/s00112-020-00889-w · Cited by 2
“Ausgehend von dem Vorteil der signifikant verringerten Strahlenexposition wurden erste Studien mit PET/MRTAnwendungen in der pädiatrischen Onkologie durchgeführt, die die technische Machbarkeit, die diagnostische Gleichwertigkeit zur PET/CTund das Potenzial für eine erweiterte multiparametrische und funktionelle Tumor…”
BackgroundSelf-citationAkram, M. S. H., Fukunaga, M., Nishikido, F., Takyu, S., Obata, T., & Yamaya, T. (2024) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.mp.2023-0061 · Cited by 1
Zukunft der Radiologie: Welche Entwicklungen können wir in den nächsten zehn Jahren erwarten?
Nensa, F., Forsting, M., & Wetter, A. (2016) · Urologe A · Cited by 1
Radioprotección y uso de contrastes en pediatría: qué, cómo y cuándo
Lancharro, A. M., & Marín, C. (2016) · Radiología · doi:10.1016/j.rx.2016.02.002 · Cited by 1
Akdemir, Ü. Ö., & Karabacak, N. İ. (2017) · Nuclear Medicine Seminars · doi:10.4274/nts.003 · Cited by 1
“görüntülemenin tercih edilmesi için başka bir gerekçe oluşturur (5,6,8,9,33,34,35,36).”
Conventional and current imaging techniques in cancer research and clinics
Barkan, N. P., Turan, S. K., Yıldızhan, H., Demiralp, D. Ö., Uslu, B., & Özkan, S. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813669-0.00012-9 · Cited by 3
PET/MRI for Clinical Pediatric Oncologic Imaging
Ponisio, M. R., Iranpour, P., Khanna, G., & McConathy, J. (2018) · Springer eBooks · doi:10.1007/978-3-319-68517-5_21 · Cited by 1
Diagnostic Applications of Nuclear Medicine: Pediatric Cancers
Pfluger, T., Ciarmiello, A., Giovacchini, G., Montravers, F., Pointe, H. D. L., Landman‐Parker, J., Meniconi, M., & Franzius, C. (2017) · Springer eBooks · doi:10.1007/978-3-319-26236-9_25 · Cited by 1
FDG PET-MRI evaluation of synchronous gallbladder adenocarcinoma and POEMS syndrome
Ataei, F., Sharma, A., Stanborough, R. O., & Parent, E. E. (2022) · Radiology Case Reports · doi:10.1016/j.radcr.2022.08.059 · Cited by 1
“[25] Schäfer JF , Gatidis S , Schmidt H , Gückel B , Bezrukov I , Pfannenberg CA , et al.”
BackgroundInfluentialNuclear Medicine Imaging of Infection/Inflammation by PET/CT and PET/MR
Amorim, B. J., Schaarschmidt, B. M., Grueneisen, J. S., Tajmir, S., Umutlu, L., Signore, A., & Catalano, O. A. (2019) · Springer eBooks · doi:10.1007/978-3-030-25494-0_14 · Cited by 1
Schäfer, J. F., Herrmann, J., Kammer, B., Koerber, F., Tsiflikas, I., Kalle, T. V., & Mentzel, H. (2021) · Der Onkologe · doi:10.1007/s00761-021-00910-1 · Cited by 1
Self-citationHu, X., Li, D., Hu, G., Huang, Q., Wang, P., & Cai, J. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00452-x · Cited by 1
“There is no radiation in the MRI examination, and PET/MR imaging can reduce the radiation dose by about 40%-70% compared with the use of PET/CT [37, 38, 40].”
MethodSchaarschmidt, B. M., Sawicki, L. M., Antoch, G., & Heusch, P. (2017) · Springer eBooks · doi:10.1007/978-3-319-69641-6_3 · Cited by 1
Gatidis, S., & Schäfer, J. F. (2019) · Pediatric oncology · doi:10.1007/978-3-030-03777-2_4 · Cited by 2
Self-citationShaikh, S. (2022) · Springer eBooks · doi:10.1007/978-981-16-9535-3_10 · Cited by 1
Hybrid PET/MR: State-of-the-Art and Future Challenges
Lin, W., Hung, S., Lee, Y. Z., & Wong, T. Z. (2017) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2017.02.001 · Cited by 1
Seith, F., Gatidis, S., Bisdas, S., la Fougère, C., Schäfer, J. F., Nikolaou, K., & Schwenzer, N. F. (2015) · Current Radiology Reports · doi:10.1007/s40134-015-0118-8
Self-citationMR/PET zur Detektion von Knochenmetastasen
Weber, M. D. (2015) · Der Radiologe · doi:10.1007/s00117-015-0001-x
Magnetic resonance–positron emission tomography
Ramalho, M., Catalano, O. A., AlObaidy, M., Altun, E., & Semelka, R. C. (2015) · Wiley eBooks · doi:10.1002/9781119012979.ch20
Yoon, S. H., Goo, J. M., Lee, S. M., Park, C. M., & Cheon, G. J. (2015)
Hybrid PET/MR: Updated Clinical Use and Potential Applications
Nunes, R. F., Barbosa, F. D. G., & Queiroz, M. A. (2016) · Current Radiology Reports · doi:10.1007/s40134-016-0191-7
Role of PET/CT in Pediatric Malignancy
Barfett, J. J., Vali, R., & Shammas, A. (2016) · Springer eBooks · doi:10.1007/978-3-319-40070-9_21
MR/PET zur Detektion von Knochenmetastasen: Der neue Goldstandard?
Weber, M. (2015) · Der Radiologe
Positron Emission Tomography/Magnetic Resonance Imaging Applications in Pediatric Imaging
Uslu, L., Akdemir, Ü. Ö., & Atay, L. Ö. (2017) · Nuclear Medicine Seminars · doi:10.4274/nts.006
Last Step in Diagnostic Imaging: Integrated PET/MR Systems and First Experiences in Turkey
Atay, L. Ö. (2017) · Nuclear Medicine Seminars · doi:10.4274/nts.001
Aydos, U., Akdemir, Ü. Ö., Özçelik, M., Gülbahar, S., Karabacak, N. İ., & Atay, L. Ö. (2017) · Nuclear Medicine Seminars · doi:10.4274/nts.007
Correction of PET Data in PET/MR Imaging
Izquierdo‐Garcia, D., & Catana, C. (2016)
PET/MRI: Reliability/Reproducibility of SUV Measurements
Zaidi, H., & Burger, I. A. (2017) · Springer eBooks · doi:10.1007/978-3-319-68517-5_6 · Cited by 2
PET/MRI in Inflammatory Diseases
Catalano, O. A., Kilcoyne, A., Lauri, C., & Signore, A. (2017) · Springer eBooks · doi:10.1007/978-3-319-69641-6_9
Radionuclide Imaging of Children
Vali, R., McQuattie, S., & Shammas, A. (2020) · Springer eBooks · doi:10.1007/978-3-030-39457-8_27
Whole-body MRI in paediatric Hodgkin lymphoma
Spijkers, S. (2020) · Utrecht University Repository (Utrecht University) · doi:10.33540/331
PET/MRI in The Evaluation of Treatment Response in Oncological Patients
Aydos, U., & Atay, L. Ö. (2021) · Nuclear Medicine Seminars · doi:10.4274/nts.galenos.2021.0021 · Cited by 1
Pediatric PET/MRI Neuroimaging: Overview
Pedersen, C. K., Messina, S. A., Daldrup-Link, H. E., & Aboian, M. (2021) · Springer eBooks · doi:10.1007/978-3-030-82367-2_62
Niri, S. G., Raghavan, P., & Wintermark, M. (2021) · Springer eBooks · doi:10.1007/978-3-030-82367-2_51
Pedersen, C. K., Link, H.-D., & Aboian, M. (2021) · Springer eBooks · doi:10.1007/978-3-030-82367-2_65
Grueneisen, J. S., & Umutlu, L. (2017) · Springer eBooks · doi:10.1007/978-3-319-69641-6_5
Daldrup-Link, H. E. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-816386-3.00075-2
Quartuccio, N., Wexler, L. H., & Schöder, H. M. (2015) · Springer eBooks · doi:10.1007/978-3-319-21371-2_14
Gatidis, S., Nikolaou, K., & Schäfer, J. F. (2017) · Springer eBooks · doi:10.1007/978-3-319-69641-6_10
Self-citationDiagnostic Applications of Nuclear Medicine: Pediatric Cancers
Pfluger, T., Ciarmiello, A., Giovacchini, G., Montravers, F., Pointe, H. D. L., Landman‐Parker, J., Meniconi, M., & Franzius, C. (2022) · Springer eBooks · doi:10.1007/978-3-319-26067-9_25-2
Jayapal, P., Rashidi, A., Baratto, L., Spunt, S. L., & Daldrup-Link, H. E. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-88537-9.00010-6
Husseini, J. S., Balza, R., Jarraya, M., Cañamaque, L. G., Barbato, F., Herrmann, K., Picchio, M., & Catalano, O. A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-88537-9.00004-0
Diagnostic Applications of Nuclear Medicine: Pediatric Cancers
Pfluger, T., Ciarmiello, A., Giovacchini, G., Montravers, F., Pointe, H. D. L., Landman‐Parker, J., Meniconi, M., & Franzius, C. (2022) · Springer eBooks · doi:10.1007/978-3-031-05494-5_25
Metadata
- Authors
- Schäfer, J. F., Gatidis, S., Schmidt, H., Gückel, B., Bezrukov, I., Pfannenberg, C. A., Reimold, M., Ebinger, M., Fuchs, J., Claussen, C. D., & Schwenzer, N. F.
- Affiliations
- University of Tübingen (DE)
- Max Planck Institute for Intelligent Systems (DE)
- University Children's Hospital Tübingen (DE)
- ORCID
- Venue
- Radiology
- Published
- 2014-10
- Volume
- 273
- Issue
- 1
- Pages
- 220-231
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2161811075
- Cited by
- 215
- References
- 28
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 7 · 2023: 15 · 2022: 18 · 2021: 15 · 2020: 14 · 2019: 12 · 2018: 18 · 2017: 35 · 2016: 41 · 2015: 24 · 2014: 3
- FWCI
- 26.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- Radiological Society of North America
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- PET/MR, PET/CT comparison, pediatric oncology, 18F-FDG, standardized uptake value, radiation dose reduction, lesion detection, solid tumors, pediatric radiation exposure, soft tissue imaging, bone marrow imaging, lung imaging, image quality assessment, image fusion
- MeSH terms
- Adolescent, Child, Contrast Media, Female, Humans, Magnetic Resonance Imaging, Male, Neoplasms, Prospective Studies, Radiation Dosage, Tomography, X-Ray Computed, Positron-Emission Tomography, Whole Body Imaging, Multimodal Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.