Simultaneous Whole-Body PET/MR Imaging in Comparison to PET/CT in Pediatric Oncology: Initial Results
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare positron emission tomography (PET)/magnetic resonance (MR) imaging and PET/computed tomography (CT) for lesion detection and interpretation, quantification of fluorine 18 ((18)F) fluorodeoxyglucose (FDG) uptake, and accuracy of MR-based PET attenuation correction in pediatric patients with solid tumors. Materials and Methods This prospective study had local ethics committee and German Federal Institute for Drugs and Medical Devices approval. Written informed consent was obtained from all patients and legal guardians. Twenty whole-body (18)F-FDG PET/CT and (18)F-FDG PET/MR examinations were performed in 18 pediatric patients (median age, 14 years; range, 11-17 years). (18)F-FDG PET/CT and (18)F-FDG PET/MR data were acquired sequentially on the same day for all patients. PET standardized uptake values (SUVs) were quantified with volume of interest measurements in lesions and healthy tissues. MR-based PET attenuation correction was compared with CT-derived attenuation maps (µ-maps). Lesion detection was assessed with separate reading of PET/CT and PET/MR data. Estimates of radiation dose were derived from the applied doses of (18)F-FDG and CT protocol parameters. Descriptive statistical analyses were performed to report correlation coefficients and relative deviations for comparison of SUVs, rates of lesion detection, and percentage reductions in radiation dose. RESULTS: PET SUVs showed strong correlations between PET of PET/CT (PETCT) and PET of PET/MR (PETMR) (r > 0.85 for most tissues). Apart from drawbacks of MR-based PET attenuation correction in osseous structures and lungs, similar SUVs were found on PET images corrected with CT-based µ-maps (13.1% deviation of SUVs for bone marrow and <5% deviation for other tissues). Lesion detection rate with PET/MR imaging was equivalent to that with PET/CT (61 areas of focal uptake on PETMR images vs 62 areas on PETCT images). Advantages of PET/MR were observed especially in soft-tissue regions. Furthermore, PET/MR offered significant dose reduction (73%) compared with PET/CT. CONCLUSION: Pediatric oncologic PET/MR is technically feasible, showing satisfactory performance for PET quantification with SUVs similar to those of PET/CT. Compared with PET/CT, PET/MR demonstrates equivalent lesion detection rates while offering markedly reduced radiation exposure. Thus, PET/MR is a promising modality for the clinical work-up of pediatric malignancies. Online supplemental material is available for this article.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Systematic underestimation of SUV in bone tissue or lesions close to the bone of >10% compared to PET/CT has been described [60,62], whereas SUV differences were <5% in other normal tissues [60].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [60]
In the citing paper
“However, several sources of error exist, including extracorporeal components such as headphones, dense hair or MR coils [59], incorrect attenuation correction factors for bone and lung tissue [60], incorrect segmentation of such compartments, and MR image truncation [61].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [60]
In the citing paper
“However, systematically different normal organ SUVs have been reported for [18F]FDG as well, which most likely result from MR-AC inaccuracies [60,65,66].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [60]
Citations
Cites
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
American Association of Physicists in Medicine
(1973) · Radiology · doi:10.1148/106.3.717b · Cited by 732
Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., Nekolla, S. G., Ziegler, S., Ganter, C., Rummeny, E. J., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.098608 · Cited by 508
Daldrup-Link, H. E., Franzius, C., Link, T. M., Laukamp, D., Sciuk, J., Jürgens, H., Schober, O., & Rummeny, E. J. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.1.1770229 · Cited by 444
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
Chawla, S. C., Federman, N., Zhang, D., Nagata, K., Nuthakki, S., McNitt-Gray, M., & Boechat, M. I. (2010) · Pediatric Radiology · doi:10.1007/s00247-009-1434-z · Cited by 218
Guidelines for 18F-FDG PET and PET-CT imaging in paediatric oncology
Stauss, J., Franzius, C., Pfluger, T., Juergens, K. U., Biassoni, L., Begent, J., Kluge, R., Amthauer, H., Voelker, T., Højgaard, L., et al. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0826-x · Cited by 190
Review of functional/anatomical imaging in oncology
Histed, S. N., Lindenberg, M. L., Mena, E., Turkbey, B., Choyke, P. L., & Kurdziel, K. A. (2012) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32834ec8a5 · Cited by 175
Pulmonary Lesion Assessment: Comparison of Whole-Body Hybrid MR/PET and PET/CT Imaging—Pilot Study
Schwenzer, N. F., Schraml, C., Müller, M., Brendle, C., Sauter, A. W., Spengler, W., Pfannenberg, A. C., Claussen, C. D., & Schmidt, H. (2012) · Radiology · doi:10.1148/radiol.12111942 · Cited by 160
Self-citation
Research works printed but not linked: 3
- Franzius C, 2010, Q J Nucl Med Mol Imaging, 54, 401
- Knopp MV, 2003, Mol Cancer Ther, 2, 419
- Bongartz G, 2004, Luxenbourg: European Commission
Cited by
Items 201–215 of 215
Voss, S. D., & Feraco, A. M. (2023) · Evidence-based imaging · doi:10.1007/978-3-030-38095-3_69-1
Preoperative 11C-Methionine PET-MRI in Pediatric Infratentorial Tumors
Beuriat, P.-A., Flaus, A., Portefaix, A., Szathmári, A., Janier, M. F., Hermier, M., Lorthois-Ninou, S., Scheiber, C., Isal, S., Costes, N., et al. (2024) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000005174
Kommentar zu „KINDER – Lymphomstaging und -restaging mit der kontrastmittelfreien FDG-PET/MRT“
Schäfer, J. F. (2024) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-2266-3765
Self-citationAnka, C., Ponisio, M. R., Dillon, P. A., Schmitt, C., Fraum, T. J., & Arbeláez, A. M. (2024) · JCEM Case Reports · doi:10.1210/jcemcr/luae153
“Endoscopic ultrasound and angiography with intra-arterial calcium stimu - lation and venous sampling are invasive and highly operator dependent, with widely varying sensitivities of 65% to 94% and 63% to 94%, respectively [12].”
BackgroundBone Neoplasms: Osteosarcoma and Ewing Sarcoma
Degnan, A. J., El-Ali, A. M., Davis, J. C., Gillman, J. A. M., & Khanna, G. (2024) · Evidence-based imaging · doi:10.1007/978-3-030-89688-1_72
Voss, S. D., & Feraco, A. M. (2024) · Evidence-based imaging · doi:10.1007/978-3-030-89688-1_69
Assessment of reduced 18F-FDG dosage in pediatric PET/MR imaging through randomized down-sampling
Tan, X., Zhou, Y., Zhang, Q., Yuan, H. S., Yao, X., Sun, C., Liu, E., & Jiang, L. (2025) · Annals of Nuclear Medicine · doi:10.1007/s12149-025-02066-z · Cited by 1
“[9, 10].”
Cox, C. P. W., Brabander, T., Verburg, F. A., & Segbers, M. (2025) · EJNMMI Physics · doi:10.1186/s40658-025-00777-w · Cited by 1
Whole-body MRI in Pediatric Langerhans Cell Histiocytosis–A Comparison With FDG-PET/CT
Baijal, N., Jana, M., Kandasamy, D., Naranje, P., Seth, R. K., Damle, N., & Khan, M. A. (2025) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0000000000003114
Imagerie multimodale et quantitative en TEP/IRM
Monnier, F. (2018) · theses.fr (ABES) · doi:10.70675/e42db410zc3b9z4427zb288z4ae150e564e5
Raja, S., Huang, H. L., Leung, C., & Gnanasegaran, G. (2026) · Springer eBooks · doi:10.1007/978-3-032-00821-3_24
Ferrari, C., & Rubini, G. (2026) · Springer eBooks · doi:10.1007/978-3-032-25634-8_11
Drews, M. A., Milosevic, A., Zensen, S., Opitz, M., Umutlu, L., Fendler, W. P., Forsting, M., Herrmann, K., Dirksen, U., & Schaarschmidt, B. M. (2026) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000002196
The trajectory of PET/MRI: from technical proof of concept to domain-specific precision imaging
Asmundo, L., Harrington, S. G., Kako, B., Queiroz, M. A., Cañamaque, L. G., Field, C. A., & Vanzulli, A. (2026) · Clinical and Translational Imaging · doi:10.1007/s40336-026-00804-5
Metadata
- Authors
- Schäfer, J. F., Gatidis, S., Schmidt, H., Gückel, B., Bezrukov, I., Pfannenberg, C. A., Reimold, M., Ebinger, M., Fuchs, J., Claussen, C. D., & Schwenzer, N. F.
- Affiliations
- University of Tübingen (DE)
- Max Planck Institute for Intelligent Systems (DE)
- University Children's Hospital Tübingen (DE)
- ORCID
- Venue
- Radiology
- Published
- 2014-10
- Volume
- 273
- Issue
- 1
- Pages
- 220-231
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2161811075
- Cited by
- 215
- References
- 28
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 7 · 2023: 15 · 2022: 18 · 2021: 15 · 2020: 14 · 2019: 12 · 2018: 18 · 2017: 35 · 2016: 41 · 2015: 24 · 2014: 3
- FWCI
- 26.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- Radiological Society of North America
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- PET/MR, PET/CT comparison, pediatric oncology, 18F-FDG, standardized uptake value, radiation dose reduction, lesion detection, solid tumors, pediatric radiation exposure, soft tissue imaging, bone marrow imaging, lung imaging, image quality assessment, image fusion
- MeSH terms
- Adolescent, Child, Contrast Media, Female, Humans, Magnetic Resonance Imaging, Male, Neoplasms, Prospective Studies, Radiation Dosage, Tomography, X-Ray Computed, Positron-Emission Tomography, Whole Body Imaging, Multimodal Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.