CoChat

Bowel Endometriosis: Preoperative Diagnostic Accuracy of 3.0-T MR Enterography—Initial Results

Rousset, Pascal, Peyron, Noémie, Charlot, Mathilde, Chateau, Florence, Golfier, François, Raudrant, Daniel, Cotte, Eddy, Isaac, Sylvie, Réty, Frédérique, Valette, Pierre-Jean · 2014 · Radiology
Cited by 88

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively determine the accuracy of 3.0-T magnetic resonance (MR) enterography in the preoperative assessment of deep infiltrating endometriosis (DIE) lesions located in the bowel above the rectosigmoid junction. MATERIALS AND METHODS: Institutional review board approval for this study was obtained, and each patient gave written informed consent. Over 18 months, patients with known pelvic DIE who were scheduled for surgery were recruited. Consecutive patients suspected of having bowel endometriosis above the rectosigmoid junction underwent 3.0-T MR enterography. Two blinded readers independently performed a systematic analysis of nine bowel segments above the rectosigmoid junction. MR images were compared with surgical and pathologic findings. Efficacy parameters were calculated with 95% confidence intervals (CIs). Interobserver agreement was assessed with κ statistics. RESULTS: Among the 43 patients enrolled in this study, 33 underwent surgery and were included in the final analyses. Sixteen (48%) patients had bowel DIE lesions located above the rectosigmoid junction at surgery and histopathologic examination. Twenty-six lesions were analyzed, including four ileal, two ileocecal, three cecal, three appendicular, and 14 sigmoid colon lesions. For the diagnosis of these lesions, MR imaging showed sensitivities of 92% (95% confidence interval [CI]: 81.7, 100) for reader 1 and 96% (95% CI: 87.1, 100) for reader 2 and specificities of 100% (95% CI: 98.8, 100) for both readers. The κ value was 0.97. CONCLUSION: These results show 3.0-T MR enterography is accurate in the preoperative diagnosis and mapping of bowel DIE lesions located above the rectosigmoid junction. Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.14132803

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 88

Metadata

Authors
Rousset, P., Peyron, N., Charlot, M., Chateau, F., Golfier, F., Raudrant, D., Cotte, E., Isaac, S., Réty, F., & Valette, P.-J.
Venue
Radiology
Published
2014-10
Volume
273
Issue
1
Pages
117-124
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2169236170
Cited by
88
References
10
FWCI
9.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bowel Endometriosis: Preoperative Diagnostic Accuracy of 3.0-T MR Enterography—Initial Results. https://app.cochat.ai/papers/10.1148/radiol.14132803
The paper
Rousset, P., Peyron, N., Charlot, M., Chateau, F., Golfier, F., Raudrant, D., Cotte, E., Isaac, S., Réty, F., & Valette, P.-J. (2014). Bowel Endometriosis: Preoperative Diagnostic Accuracy of 3.0-T MR Enterography—Initial Results. Radiology. https://doi.org/10.1148/radiol.14132803

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.