Closing in on the K Edge: Coronary CT Angiography at 100, 80, and 70 kV—Initial Comparison of a Second- versus a Third-Generation Dual-Source CT System
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively evaluate radiation and contrast medium requirements for performing high-pitch coronary computed tomographic (CT) angiography at 70 kV using a third-generation dual-source CT system in comparison to a second-generation dual-source CT system. MATERIALS AND METHODS: All patients gave informed consent for this institutional review board-approved study. Forty-five patients (median age, 52 years; 27 men) were imaged in high-pitch mode with a third-generation dual-source CT system at 70 kV (n = 15) or with a second-generation dual-source CT system at 80 or 100 kV (n = 15 for each). Tube voltage was based on body mass index: 80 or 70 kV for less than 26 kg/m(2) versus 100 kV for 26-30 kg/m(2). For the 80- and 100-kV protocols, 80 mL of contrast material was injected, versus 45 mL for the 70-kV protocol. Data were reconstructed by using a second-generation iterative reconstruction algorithm for second-generation dual-source CT and a recently introduced third-generation iterative reconstruction algorithm for third-generation dual-source CT. Objective image quality was measured for various regions of interest, and subjective image quality was evaluated with a five-point Likert scale. RESULTS: The signal-to-noise ratio of the coronary CT angiography studies acquired with 70 kV was significantly higher (70 kV: 14.3-17.6 vs 80 kV: 7.1-12.9 vs 100 kV: 9.8-12.9; P < .0497) than those acquired with the other two protocols for all coronary arteries. Qualitative image quality analyses revealed no significant differences between the three CT angiography protocols (median score, 5; P > .05). The mean effective dose was 75% and 108% higher (0.92 mSv ± 0.3 [standard deviation] and 0.78 mSv ± 0.2 vs 0.44 mSv ± 0.1; P < .0001), respectively, for the 80- and 100-kV CT angiography protocols than for the 70-kV CT angiography protocol. CONCLUSION: In nonobese patients, third-generation high-pitch coronary dual-source CT angiography at 70 kV results in robust image quality for studying the coronary arteries, at significantly reduced radiation dose (0.44 mSv) and contrast medium volume (45 mL), thus enabling substantial radiation dose and contrast medium savings as compared with second-generation dual-source CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Contrast-induced kidney injury: mechanisms, risk factors, and prevention
Seeliger, E., Sendeski, M., Rihal, C. S., & Persson, P. B. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr494 · Cited by 520
McCollough, C. H., Chen, G. H., Kalender, W., Leng, S., Samei, E., Taguchi, K., Wang, G., Yu, L., & Pettigrew, R. I. (2012) · Radiology · doi:10.1148/radiol.12112265 · Cited by 276
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.11.001 · Cited by 256
Effects of Radiation Exposure From Cardiac Imaging
Einstein, A. J. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.079 · Cited by 215
Renker, M., Nance, J. W., Schoepf, U. J., O’Brien, T. X., Zwerner, P. L., Meyer, M., Kerl, J. M., Bauer, R. W., Fink, C., Vogl, T. J., et al. (2011) · Radiology · doi:10.1148/radiol.11103574 · Cited by 182
Self-citationAchenbach, S., Goroll, T., Seltmann, M., Pflederer, T., Anders, K., Ropers, D., Daniel, W. G., Uder, M., Lell, M., & Marwan, M. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.01.012 · Cited by 164
Abdulla, J., Asferg, C. L., & Kofoed, K. F. (2010) · International journal of cardiac imaging · doi:10.1007/s10554-010-9652-x · Cited by 96
Oda, S., Utsunomiya, D., Funama, Y., Awai, K., Katahira, K., Nakaura, T., Yanaga, Y., Namimoto, T., & Yamashita, Y. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.03.007 · Cited by 55
Komatsu, S., Kamata, T., Imai, A., Ohara, T., Takewa, M., Ohe, R., Miyaji, K., Yoshida, J., & Kodama, K. (2013) · International journal of cardiac imaging · doi:10.1007/s10554-013-0201-2 · Cited by 37
Clinical assessment of chest pain and guidelines for imaging
Gruettner, J., Henzler, T., Sueselbeck, T., Fink, C., Borggrefe, M. M., & Walter, T. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.01.063 · Cited by 21
Self-citation
Metadata
- Authors
- Meyer, M., Haubenreisser, H., Schoepf, U. J., Vliegenthart, R., Leidecker, C., Allmendinger, T., Lehmann, R., Sudarski, S., Borggrefe, M., Schoenberg, S. O., & Henzler, T.
- Venue
- Radiology
- Published
- 2014-11
- Volume
- 273
- Issue
- 2
- Pages
- 373-382
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2140105263
- Cited by
- 187
- References
- 11
- FWCI
- 21.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.