The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Metrology Standards for Quantitative Imaging Biomarkers
Open accessAbstract
Although investigators in the imaging community have been active in developing and evaluating quantitative imaging biomarkers (QIBs), the development and implementation of QIBs have been hampered by the inconsistent or incorrect use of terminology or methods for technical performance and statistical concepts. Technical performance is an assessment of how a test performs in reference objects or subjects under controlled conditions. In this article, some of the relevant statistical concepts are reviewed, methods that can be used for evaluating and comparing QIBs are described, and some of the technical performance issues related to imaging biomarkers are discussed. More consistent and correct use of terminology and study design principles will improve clinical research, advance regulatory science, and foster better care for patients who undergo imaging studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
On the Theory of Scales of Measurement
Stevens, S. S. (1946) · Science · doi:10.1126/science.103.2684.677 · Cited by 4,761
Contributions to Probability and Statistics: Essays in Honor of Harold Hotelling.
David, F. N., Olkin, I., Ghurye, S. G., Hoeffding, W., Madow, W. G., & Mann, H. B. (1961) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2984135 · Cited by 1,914
Nonparametric analysis of longitudinal data in factorial experiments
Brunner, E., Domhof, S., & Langer, F. (2002) · Cited by 635
Poste, G. (2011) · Nature · doi:10.1038/469156a · Cited by 582
Statistical Methods in Assessing Agreement: Models, Issues, and Tools
Lin, L., Hedayat, A. S., Sinha, B., & Yang, M. (2002) · Journal of the American Statistical Association · doi:10.1198/016214502753479392 · Cited by 413
Raunig, D. L., McShane, L. M., Pennello, G., Gatsonis, C., Carson, P. L., Voyvodic, J. T., Wahl, R. L., Kurland, B. F., Schwarz, A. J., Gönen, M., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537344 · Cited by 394
Self-citationReproducibility of metabolic measurements in malignant tumors using FDG PET.
Weber, W., Ziegler, S. I., Thödtmann, R., Hanauske, A.-R., & Schwaiger, M. (1999) · PubMed · Cited by 388
Kessler, L. G., Barnhart, H. X., Buckler, A. J., Choudhury, K. R., Kondratovich, M. V., Toledano, A., Guimaraes, A. R., Filice, R., Zhang, Z., Sullivan, D. C., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537333 · Cited by 293
Self-citationFinding What Works in Health Care: Standards for Systematic Reviews
Committee on Standards for Systematic Reviews of Comparative Effectiveness Research, Board on Health Care Services, & Institute of Medicine (2011) · doi:10.17226/13059 · Cited by 289
Minn, H., Zasadny, K. R., Quint, L. E., & Wahl, R. L. (1995) · Radiology · doi:10.1148/radiology.196.1.7784562 · Cited by 260
Self-citationQuantitative imaging biomarkers: A review of statistical methods for computer algorithm comparisons
Obuchowski, N. A., Reeves, A. P., Huang, E. P., Wang, X.-F., Buckler, A. J., Kim, H. J. (., Barnhart, H. X., Jackson, E. F., Giger, M. L., Pennello, G., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537390 · Cited by 172
Self-citationMethods to monitor response to chemotherapy in non-small cell lung cancer with 18F-FDG PET.
Hoekstra, C. J., Hoekstra, O. S., Stroobants, S. G., Vansteenkiste, J., Nuyts, J. L., Smit, E. F., Boers, M., Twisk, J. W. R., & Lammertsma, A. A. (2002) · PubMed · Cited by 136
Accuracy and Precision of Radioactivity Quantification in Nuclear Medicine Images
Frey, E. C., Humm, J. L., & Ljungberg, M. H. (2012) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.11.003 · Cited by 103
Qualification of imaging biomarkers for oncology drug development
Waterton, J. C., & Pylkkänen, L. H. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.037 · Cited by 74
Modelling method comparison data
Dunn, G., & Roberts, C. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800205 · Cited by 70
Obuchowski, N. A., Barnhart, H. X., Buckler, A. J., Pennello, G. A., Wang, X., Kalpathy–Cramer, J., Kim, G. H. J., Reeves, A. P., & for the Case Example Working Group (2014) · Statistical Methods in Medical Research · doi:10.1177/0962280214537392 · Cited by 64
Self-citationObjective comparison of quantitative imaging modalities without the use of a gold standard
Hoppin, J., Kupinski, M. A., Kastis, G. A., Clarkson, E. W., & Barrett, H. H. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009380 · Cited by 57
Huang, E. P., Wang, X. F., Choudhury, K. R., McShane, L. M., Gönen, M., Ye, J., Buckler, A. J., Kinahan, P. E., Reeves, A. P., Jackson, E. F., et al. (2014) · Statistical Methods in Medical Research · doi:10.1177/0962280214537394 · Cited by 52
Self-citationESR statement on the stepwise development of imaging biomarkers
European Society of Radiology (ESR) (2013) · Insights into Imaging · doi:10.1007/s13244-013-0220-5 · Cited by 46
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Imaging biomarker roadmap for cancer studies
O'Connor, J. P. B., Aboagye, E. O., Adams, J. E., Aerts, H. J. W. L., Barrington, S. F., Beer, A. J., Boellaard, R., Bohndiek, S. E., Brady, M., Brown, G., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.162 · Cited by 1,091
Self-citationAI in Medical Imaging Informatics: Current Challenges and Future Directions
Panayides, A. S., Amini, A., Filipovic, N. D., Sharma, A., Tsaftaris, S. A., Young, A., Foran, D., Do, N., Golemati, S., Kurc, T., et al. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2991043 · Cited by 713
Metadata
- Authors
- Sullivan, D. C., Obuchowski, N. A., Kessler, L. G., Raunig, D. L., Gatsonis, C., Huang, E. P., Kondratovich, M., McShane, L. M., Reeves, A. P., Barboriak, D. P., Guimaraes, A. R., Wahl, R. L., & For the RSNA-QIBA Metrology Working Group
- Venue
- Radiology
- Published
- 2015-12
- Volume
- 277
- Issue
- 3
- Pages
- 813-825
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1834986685
- Cited by
- 435
- References
- 22
- FWCI
- 24.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.