The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Quantitative imaging biomarkers: A review of statistical methods for computer algorithm comparisons
Open accessAbstract
Quantitative biomarkers from medical images are becoming important tools for clinical diagnosis, staging, monitoring, treatment planning, and development of new therapies. While there is a rich history of the development of quantitative imaging biomarker (QIB) techniques, little attention has been paid to the validation and comparison of the computer algorithms that implement the QIB measurements. In this paper we provide a framework for QIB algorithm comparisons. We first review and compare various study designs, including designs with the true value (e.g. phantoms, digital reference images, and zero-change studies), designs with a reference standard (e.g. studies testing equivalence with a reference standard), and designs without a reference standard (e.g. agreement studies and studies of algorithm precision). The statistical methods for comparing QIB algorithms are then presented for various study types using both aggregate and disaggregate approaches. We propose a series of steps for establishing the performance of a QIB algorithm, identify limitations in the current statistical literature, and suggest future directions for research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Armato, S. G., McLennan, G., Bidaut, L., McNitt‐Gray, M. F., Meyer, C. R., Reeves, A. P., Zhao, B., Aberle, D. R., Henschke, C. I., Hoffman, E. A., et al. (2011) · Medical Physics · doi:10.1118/1.3528204 · Cited by 2,887
Self-citationSchuirmann, D. J. (1987) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01068419 · Cited by 2,696
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513 · cited 2×
“Passing and Bablok describe a nonparametric technique to estimate the intercept and slope parameters j and j for a single QIB algorithm, in the presence of an imperfect reference standard, when both the QIB algorithm measurement errors ij and the reference standard measurement errors i are heteroscedastic but have var…”
BackgroundMethodRepeatability of 18F-FDG Uptake Measurements in Tumors: A Metaanalysis
de Langen, A. J., Vincent, A., Velasquez, L. M., van Tinteren, H., Boellaard, R., Shankar, L. K., Boers, M., Smit, E. F., Stroobants, S., Weber, W. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.095299 · Cited by 157
Variance of SUVs for FDG-PET/CT is Greater in Clinical Practice Than Under Ideal Study Settings
Kumar, V., Nath, K., Berman, C. G., Kim, J., Tanvetyanon, T., Chiappori, A. A., Gatenby, R. A., Gillies, R. J., & Eikman, E. A. (2013) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318279ffdf · Cited by 76
Self-citation
Cited by
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
Self-citationRaunig, D. L., McShane, L. M., Pennello, G., Gatsonis, C., Carson, P. L., Voyvodic, J. T., Wahl, R. L., Kurland, B. F., Schwarz, A. J., Gönen, M., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537344 · Cited by 394
Self-citationDrukker, K., Chen, W., Gichoya, J. W., Gruszauskas, N. P., Kalpathy-Cramer, J., Koyejo, S., Myers, K. J., Sá, R. C., Sahiner, B., Whitney, H. M., et al. (2023) · Journal of Medical Imaging · doi:10.1117/1.jmi.10.6.061104 · Cited by 149
Self-citation
Metadata
- Authors
- Obuchowski, N. A., Reeves, A. P., Huang, E. P., Wang, X.-F., Buckler, A. J., Kim, H. J. (., Barnhart, H. X., Jackson, E. F., Giger, M. L., Pennello, G., Toledano, A. Y., Kalpathy-Cramer, J., Apanasovich, T. V., Kinahan, P. E., Myers, K. J., Goldgof, D. B., Barboriak, D. P., Gillies, R. J., Schwartz, L. H., Sullivan, D. C., & (for the Algorithm Comparison Working Group)
- Venue
- Statistical Methods in Medical Research
- Publisher
- SAGE Publications
- Published
- 2014-06-11
- Volume
- 24
- Issue
- 1
- Pages
- 68-106
- ISSN
- 0962-2802 (ISSN-L)
- 1477-0334
- OpenAlex
- W2072484199
- Cited by
- 172
- References
- 10
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative imaging biomarkers: A review of statistical methods for computer algorithm comparisons. https://app.cochat.ai/papers/10.1177/0962280214537390
- The paper
- Obuchowski, N. A., Reeves, A. P., Huang, E. P., Wang, X.-F., Buckler, A. J., Kim, H. J. (., Barnhart, H. X., Jackson, E. F., Giger, M. L., Pennello, G., Toledano, A. Y., Kalpathy-Cramer, J., Apanasovich, T. V., Kinahan, P. E., Myers, K. J., Goldgof, D. B., Barboriak, D. P., Gillies, R. J., Schwartz, L. H., . . . (for the Algorithm Comparison Working Group). (2015). Quantitative imaging biomarkers: A review of statistical methods for computer algorithm comparisons. Statistical Methods in Medical Research. https://doi.org/10.1177/0962280214537390
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.