Accelerating MR Imaging Liver Steatosis Measurement Using Combined Compressed Sensing and Parallel Imaging: A Quantitative Evaluation
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the limits of agreement of hepatic fat fraction and R2* relaxation rate quantified with accelerated magnetic resonance (MR) imaging reconstructed with combined compressed sensing and parallel imaging compared with conventional fully sampled acquisitions. MATERIALS AND METHODS: Eleven subjects with type 2 diabetes and a healthy control subject were recruited with the approval of the Newcastle and North Tyneside 2 ethics committee and written consent. Undersampled data at ratios of 2.6×, 2.9×, 3.8×, and 4.8× were prospectively acquired in addition to fully sampled data by using five gradient echoes per repetition time at 3.0 T. Fat fraction maps were calculated by using combined compressed sensing and parallel imaging (CS-PI) reconstruction and Bland-Altman analysis performed to assess bias and 95% limits of agreement. Inter- and intrarater analysis was performed for quantitative fat fraction and R2* relaxation rate, and image quality was assessed with a four-point scale by two independent observers. RESULTS: The fat fractions from the accelerated acquisitions had 95% limits of agreement of 1.2%, 1.2%, 1.1%, and 1.5%, respectively, with no bias. When compared with the intra- and interrater 95% limits of agreement (0.7% and 0.8%), acceleration of up to 3.8× did not greatly degrade the fat fraction measurements. No or minimal artifact was detected at 2.6× and 2.9× accelerations, moderate artifact was detected at 3.8× acceleration, and substantial artifact was detected at 4.8× acceleration. CONCLUSION: Prospective undersampling and CS-PI reconstruction of liver fat fractions can be used to accelerate liver fat fraction measurements. The fat fractions and image quality produced were acceptable up to a factor of 3.8×, thereby shortening the required breath-hold duration from 17.7 seconds to 4.7 seconds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Dixon, J. B., O’Brien, P. E., Playfair, J., Chapman, L., Schachter, L. M., Skinner, S., Proietto, J., Bailey, M., & Anderson, M. (2008) · JAMA · doi:10.1001/jama.299.3.316 · Cited by 1,434
Lim, E. L., Hollingsworth, K. G., Aribisala, B. S., Chen, M. J., Mathers, J. C., & Taylor, R. (2011) · Diabetologia · doi:10.1007/s00125-011-2204-7 · Cited by 1,164
Self-citationTaylor, R. (2013) · Diabetes Care · doi:10.2337/dc12-1805 · Cited by 485
Self-citation
Cited by
Quantification of liver fat content with CT and MRI: state of the art
Starekova, J., Hernando, D., Pickhardt, P. J., & Reeder, S. B. (2021) · Radiology · doi:10.1148/radiol.2021204288 · Cited by 320
Compressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Jang, W., & Song, J. S. (2023) · Diagnostics · doi:10.3390/diagnostics13111852 · Cited by 55
Validation of a free software for unsupervised assessment of abdominal fat in MRI
Maddalo, M., Zorza, I., Zubani, S., Nocivelli, G., Calandra, G., Soldini, P., Mascaro, L., & Maroldi, R. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.04.002 · Cited by 17
Metadata
- Authors
- Mann, L. W., Higgins, D. M., Peters, C. N., Cassidy, S., Hodson, K. K., Coombs, A., Taylor, R., & Hollingsworth, K. G.
- Venue
- Radiology
- Published
- 2016-01
- Volume
- 278
- Issue
- 1
- Pages
- 247-256
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2110003651
- Cited by
- 44
- References
- 5
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.