Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record.

Quantitative Shear-Wave US Elastography of the Supraspinatus Muscle: Reliability of the Method and Relation to Tendon Integrity and Muscle Quality

Rosskopf, Andrea B., Ehrmann, Christine, Buck, Florian M., Gerber, Christian, Flück, Martin, Pfirrmann, Christian W. A. · 2016 · Radiology

Abstract

PURPOSE: To evaluate the reliability of ultrasonographic (US) elastography of the supraspinatus (SSP) muscle, define normal shear-wave velocity (SWV) values, and correlate findings with tendon integrity and muscle quality. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained from all patients. SSP SWV (in meters per second) was prospectively assessed twice in 22 asymptomatic volunteers (mean age ± standard deviation, 53.8 years ± 15.3; 11 women and 11 men) by two independent examiners by using shear-wave elastography. Forty-four patients (mean age, 51.9 years ± 15.0; 22 women and 22 men) were prospectively included. SWV findings were compared with tendon integrity, tendon retraction (Patte classification), fatty muscle infiltration (Goutallier stages 0-IV), and muscle volume atrophy (tangent sign) on magnetic resonance (MR) images. Descriptive statistics, Spearman correlation, analysis of variance, two-sample t test, and intraclass correlation coefficient (ICC) were used. RESULTS: Test-retest reliability for mean total SWV (MTSWV) was good for examiner 1 (ICC = 0.70; 95% confidence interval [CI]: 0.30, 0.87; P = .003) and excellent for examiner 2 (ICC = 0.80; 95% CI: 0.53, 0.92; P < .001). Interexaminer reliability was excellent (ICC = 0.89; 95% CI: 0.64, 0.96; P < .001). MTSWV in volunteers (3.0 m/sec ± 0.5) was significantly higher than that in patients (2.5 m/sec ± 0.5; P = .001). For tendon integrity, no significant difference in MTSWV was found. For tendon retraction, MTSWV varies significantly between patients with different degrees of retraction (P = .047). No significant differences were found for Goutallier subgroups. MTSWV was significantly lower with a positive tangent sign (P = .015; n = 10). CONCLUSION: Shear-wave elastography is reproducible for assessment of the SSP muscle. Mean normal SSP SWV is 3.0 m/sec ± 0.5. SWV decreases with increasing fat content (Goutallier stage 0-III) and increases in the final stage of fatty infiltration (Goutallier stage IV).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2015150908

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Rosskopf, A. B., Ehrmann, C., Buck, F. M., Gerber, C., Flück, M., & Pfirrmann, C. W. A.
Venue
Radiology
Published
2016-02
Volume
278
Issue
2
Pages
465-474
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2154318378
Cited by
159
References
0
FWCI
8.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative Shear-Wave US Elastography of the Supraspinatus Muscle: Reliability of the Method and Relation to Tendon Integrity and Muscle Quality. https://app.cochat.ai/papers/10.1148/radiol.2015150908
The paper
Rosskopf, A. B., Ehrmann, C., Buck, F. M., Gerber, C., Flück, M., & Pfirrmann, C. W. A. (2016). Quantitative Shear-Wave US Elastography of the Supraspinatus Muscle: Reliability of the Method and Relation to Tendon Integrity and Muscle Quality. Radiology. https://doi.org/10.1148/radiol.2015150908

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.