CoChat
Cited by 376

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Can Current Preoperative Imaging Be Used to Detect Microvascular Invasion of Hepatocellular Carcinoma?

Open access
Renzulli, Matteo, Brocchi, Stefano, Cucchetti, Alessandro, Mazzotti, Federico, Mosconi, Cristina, Sportoletti, Camilla, Brandi, Giovanni, Pinna, Antonio Daniele, Golfieri, Rita · 2016 · Radiology

Abstract

PURPOSE: To determine the accuracy of imaging features, such as tumor dimension, multinodularity, nonsmooth tumor margins, peritumoral enhancement, and radiogenomic algorithm based on the association between imaging features (internal arteries and hypoattenuating halos) and gene expression that the authors called two-trait predictor of venous invasion (TTPVI), in the prediction of microvascular invasion (MVI) in hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This single-center retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. One hundred twenty-five patients (median age, 63 years; interquartile range, 53-71 years) with a diagnosis of HCC and indications for hepatic resection were included. Two observers independently reviewed radiologic images to evaluate the following features for MVI: maximum diameter, number of lesions, tumor margins, TTPVI, and peritumoral enhancement. Interobserver agreement was checked, and diagnostic accuracy of radiologic features was investigated. RESULTS: The total number of HCC nodules was 140. Large tumor size, nonsmooth tumor margins, TTPVI, and peritumoral enhancement were significantly related to the presence of MVI (P < .05 in all cases and for both observers). Multinodularity was not significantly related (P = .158). Moreover, the diagnostic accuracy of the three "worrisome" radiologic features (nonsmooth tumor margins, peritumoral enhancement, and TTPVI) was associated with tumor size: The negative predictive value of the absence of worrisome features decreased from 0.84 for observer 1 and 0.91 for observer 2 for tumors smaller than 2 cm to 0.56 and 0.71, respectively, for tumors larger than 5 cm, whereas the presence of all three worrisome features returned to a positive predictive value of 0.95 for observer 1 and 0.96 for observer 2 independent of tumor size, with no significant interobserver differences (P > .10). CONCLUSION: "Worrisome" imaging features, such as tumor dimension, nonsmooth tumor margins, peritumoral enhancement, and TTPVI, have high accuracy in the prediction of MVI in HCC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2015150998

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 376

Metadata

Authors
Renzulli, M., Brocchi, S., Cucchetti, A., Mazzotti, F., Mosconi, C., Sportoletti, C., Brandi, G., Pinna, A. D., & Golfieri, R.
Venue
Radiology
Published
2016-05
Volume
279
Issue
2
Pages
432-442
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2191988973
Cited by
376
References
24
FWCI
8.02
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.