The DOI matches its Crossref record.
Proposed Adjustments to PI-RADS Version 2 Decision Rules: Impact on Prostate Cancer Detection
Abstract
Purpose To test the impact of existing Prostate Imaging Reporting and Data System (PI-RADS) version 2 (V2) decision rules, as well as of proposed adjustments to these decision rules, on detection of Gleason score (GS) 7 or greater (GS ≥7) prostate cancer. Materials and Methods Two radiologists independently provided PI-RADS V2 scores for the dominant lesion on 343 prostate magnetic resonance (MR) examinations. Diagnostic performance for GS ≥7 tumor was assessed by using MR imaging-ultrasonography fusion-targeted biopsy as the reference. The impact of existing PI-RADS V2 decision rules, as well as a series of exploratory proposed adjustments, on the frequency of GS ≥7 tumor detection, was evaluated. Results A total of 210 lesions were benign, 43 were GS 6, and 90 were GS ≥7. Lesions were GS ≥7 in 0%–4.1% of PI-RADS categories 1 and 2, 11.4%–27.1% of PI-RADS category 3, 44.4%–49.3% of PI-RADS category 4, and 72.1%–73.7% of PI-RADS category 5 lesions. PI-RADS category 4 or greater had sensitivity of 78.9%–87.8% and specificity of 75.5%-79.1 for detecting GS ≥7 tumor. The frequency of GS ≥7 tumor for existing PI-RADS V2 decision rules was 30.0%–33.3% in peripheral zone (PZ) lesions upgraded from category 3 to 4 based on dynamic contrast enhancement (DCE) score of positive; 50.0%–66.7% in transition zone (TZ) lesions upgraded from category 3 to 4 based on diffusion-weighted imaging (DWI) score of 5; and 71.7%–72.7% of lesions in both zones upgraded from category 4 to 5 based on size of 15 mm or greater. The frequency of GS ≥7 tumor for proposed adjustments to the decision rules was 30.0%–60.0% for TZ lesions upgraded from category 3 to 4 based on DWI score of 4; 33.3%–57.1% for TZ lesions upgraded from category 3 to 4 based on DCE score of positive when incorporating new criteria (unencapsulated sheetlike enhancement) for DCE score of positive in TZ; and 56.4%–61.9% for lesions in both zones upgraded from category 4 to 5 based on size of 10–14 mm. Other proposed adjustments yielded GS ≥7 tumor in less than 15% of cases for one or more readers. Conclusion Existing PI-RADS V2 decision rules exhibited reasonable performance in detecting GS ≥7 tumor. Several proposed adjustments to the criteria (in TZ, upgrading category 3 to 4 based on DWI score of 4 or modified DCE score of positive; in PZ or TZ, upgrading category 4 to 5 based on size of 10–14 mm) may also have value for this purpose. © RSNA, 2016 Online supplemental material is available for this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Turkbey, B., Rosenkrantz, A. B., Haider, M. A., Padhani, A. R., Villeirs, G., Macura, K. J., Tempany, C. M., Choyke, P. L., Cornud, F., Margolis, D. J., et al. (2019) · European Urology · doi:10.1016/j.eururo.2019.02.033 · Cited by 2,544
Self-citationDrost, F.-J. H., Osses, D. F., Nieboer, D., Steyerberg, E. W., Bangma, C. H., Roobol, M. J., & Schoots, I. G. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012663.pub2 · Cited by 640
Woo, S., Suh, C. H., Kim, S. Y., Cho, J. Y., & Kim, S. H. (2017) · European Urology · doi:10.1016/j.eururo.2017.01.042 · Cited by 308
Metadata
- Authors
- Rosenkrantz, A. B., Babb, J. S., Taneja, S. S., & Ream, J. M.
- Venue
- Radiology
- Published
- 2017-04
- Volume
- 283
- Issue
- 1
- Pages
- 119-129
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2541210714
- Cited by
- 168
- References
- 0
- FWCI
- 20.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.