Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 539

The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.

Diagnostic Performance of CT and Reverse Transcriptase Polymerase Chain Reaction for Coronavirus Disease 2019: A Meta-Analysis

Open access
Kim, Hyungjin, Hong, Hyunsook, Yoon, Soon Ho·2020·Radiology

Abstract

Background Recent studies have suggested that chest CT scans could be used as a primary screening or diagnostic tool for coronavirus disease 2019 (COVID-19) in epidemic areas. Purpose To perform a meta-analysis to evaluate diagnostic performance measures, including predictive values of chest CT and initial reverse transcriptase polymerase chain reaction (RT-PCR). Materials and Methods Medline and Embase were searched from January 1, 2020, to April 3, 2020, for studies on COVID-19 that reported the sensitivity, specificity, or both of CT scans, RT-PCR assays, or both. The pooled sensitivity and specificity were estimated by using random-effects models. The actual prevalence (ie, the proportion of confirmed patients among those tested) in eight countries was obtained from web sources, and the predictive values were calculated. Meta-regression was performed to reveal the effect of potential explanatory factors on the diagnostic performance measures. Results The pooled sensitivity was 94% (95% confidence interval [CI]: 91%, 96%; I2 = 95%) for chest CT and 89% (95% CI: 81%, 94%; I2 = 90%) for RT-PCR. The pooled specificity was 37% (95% CI: 26%, 50%; I2 = 83%) for chest CT. The prevalence of COVID-19 outside China ranged from 1.0% to 22.9%. For chest CT scans, the positive predictive value (PPV) ranged from 1.5% to 30.7%, and the negative predictive value (NPV) ranged from 95.4% to 99.8%. For RT-PCR, the PPV ranged from 47.3% to 96.4%, whereas the NPV ranged from 96.8% to 99.9%. The sensitivity of CT was affected by the distribution of disease severity, the proportion of patients with comorbidities, and the proportion of asymptomatic patients (all P < .05). The sensitivity of RT-PCR was negatively associated with the proportion of elderly patients (P = .01). Conclusion Outside of China where there is a low prevalence of coronavirus disease 2019 (range, 1%–22.9%), chest CT screening of patients with suspected disease had low positive predictive value (range, 1.5%–30.7%). © RSNA, 2020 Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2020201343

Cites

74 of 74 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 74 references

Cited by

See all 539

Metadata

Authors
Kim, H., Hong, H., & Yoon, S. H.
Venue
Radiology
Published
2020-09
Volume
296
Issue
3
Pages
E145-E155
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W3016484923
Cited by
539
References
74
FWCI
7.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Performance of CT and Reverse Transcriptase Polymerase Chain Reaction for Coronavirus Disease 2019: A Meta-Analysis. https://app.cochat.ai/papers/10.1148/radiol.2020201343
The paper
Kim, H., Hong, H., & Yoon, S. H. (2020). Diagnostic Performance of CT and Reverse Transcriptase Polymerase Chain Reaction for Coronavirus Disease 2019: A Meta-Analysis. Radiology. https://doi.org/10.1148/radiol.2020201343

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.