CoChat

Quantitative Functional Evaluation of Liver Fibrosis in Mice with Dynamic Contrast-enhanced Photoacoustic Imaging

Lv, Jing, Xu, Yue, Xu, Ling, Nie, Liming · 2021 · Radiology
Cited by 119

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background Dynamic contrast-enhanced (DCE) photoacoustic (PA) imaging (PAI) is a novel noninvasive imaging modality that uses the differences in optical absorption of oxyhemoglobin and deoxyhemoglobin and may be performed in a dynamic fashion to image the indocyanine green (ICG) pharmacokinetics in the liver. Purpose To determine whether DCE PAI parameters (maximum peak time [Tmax] and half-life [T1/2]) derived from the PA liver function curve correlate with fibrosis determined using histopathologic analysis. Materials and Methods Between June 2020 and October 2020, 28 male mice aged 8 weeks were intraperitoneally injected with carbon tetrachloride solution every 2 days to establish a liver fibrosis model. At the 1st, 4th, and 8th week of modeling, the changes in liver structure were monitored dynamically by using a PA technique. The Tmax and T1/2 of ICG were calculated at different pathologic stages and within a control group. Corresponding liver histopathologic results and blood biochemical data were obtained. Spearman rank correlation was used to evaluate the relationship between the DCE PAI results and histologic scores. Results The PA liver function curve showed that the Tmax and T1/2 varied among groups (mean Tmax: control group, 9 seconds ± 1.8 [standard deviation]; 1 week, 51 seconds ± 4.4; 4 weeks, 73 seconds ± 5.3; 8 weeks, 104 seconds ± 6.6; P < .001) (mean T1/2: control group, 28 seconds ± 6.5; 1 week, 201 seconds ± 12.4; 4 weeks, 285 seconds ± 11; 8 weeks, 318 seconds ± 30.5; P < .001). There was a positive correlation between the dynamic parameters (Tmax and T1/2) and the histopathologic scores; the Spearman ρ ratios for the Sirius red and α-smooth muscle actin (αSMA)–positive areas versus the Tmax were 0.93 and 0.94 (P < .001 for both), and the Spearman ρ ratios for the Sirius red and αSMA–positive areas versus T1/2 were 0.87 and 0.89 (P < .001 for both). Conclusion Dynamic contrast-enhanced photoacoustic imaging demonstrated a higher maximum peak time and half-life in mice with induced fibrosis compared with control mice without fibrosis, and these values correlated with histologic measures of fibrosis. © RSNA, 2021 Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2021204134

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Lv, J., Xu, Y., Xu, L., & Nie, L.
Venue
Radiology
Published
2021-07
Volume
300
Issue
1
Pages
89-97
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W3158866447
Cited by
119
References
3
FWCI
5.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.