The Need for Medical Artificial Intelligence That Incorporates Prior Images
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The use of artificial intelligence (AI) has grown dramatically in the past few years in the United States and worldwide, with more than 300 AI-enabled devices approved by the U.S. Food and Drug Administration (FDA). Most of these AI-enabled applications focus on helping radiologists with detection, triage, and prioritization of tasks by using data from a single point, but clinical practice often encompasses a dynamic scenario wherein physicians make decisions on the basis of longitudinal information. Unfortunately, benchmark data sets incorporating clinical and radiologic data from several points are scarce, and, therefore, the machine learning community has not focused on developing methods and architectures suitable for these tasks. Current AI algorithms are not suited to tackle key image interpretation tasks that require comparisons to previous examinations. Focusing on the curation of data sets and algorithm development that allow for comparisons at different points will be required to advance the range of relevant tasks covered by future AI-enabled FDA-cleared devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
Derivation, Validation, and Potential Treatment Implications of Novel Clinical Phenotypes for Sepsis
Seymour, C. W., Kennedy, J. N., Wang, S., Chang, C.-C. H., Elliott, C. F., Xu, Z., Berry, S., Clermont, G., Cooper, G., Gomez, H., et al. (2019) · JAMA · doi:10.1001/jama.2019.5791 · Cited by 1,567
Benjamens, S., Dhunnoo, P., & Meskó, B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00324-0 · Cited by 1,215
Littlejohns, T. J., Holliday, J., Gibson, L. M., Garratt, S., Oesingmann, N., Alfaro-Almagro, F., Bell, J. D., Boultwood, C., Collins, R., Conroy, M. C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15948-9 · Cited by 812
An algorithmic approach to reducing unexplained pain disparities in underserved populations
Pierson, E., Cutler, D. M., Leskovec, J., Mullainathan, S., & Obermeyer, Z. (2021) · Nature Medicine · doi:10.1038/s41591-020-01192-7 · Cited by 268
Cited by
The current and future state of AI interpretation of medical images
Rajpurkar, P., & Lungren, M. P. (2023) · New England Journal of Medicine · doi:10.1056/nejmra2301725 · Cited by 443
Self-citationHan, R., Acosta, J. N., Shakeri, Z., Ioannidis, J. P. A., Topol, E. J., & Rajpurkar, P. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00047-5 · Cited by 336
Self-citationFDA Review of Radiologic AI Algorithms: Process and Challenges
Zhang, K., Khosravi, B., Vahdati, S., & Erickson, B. J. (2024) · Radiology · doi:10.1148/radiol.230242 · Cited by 46
Vaidhya Venkadesh, K., Aleef, T. A., Scholten, E. T., Saghir, Z., Silva, M., Sverzellati, N., Pastorino, U., van Ginneken, B., Prokop, M., & Jacobs, C. (2023) · Radiology · doi:10.1148/radiol.223308 · Cited by 32
Metadata
- Authors
- Acosta, J. N., Falcone, G. J., & Rajpurkar, P.
- Venue
- Radiology
- Published
- 2022-08
- Volume
- 304
- Issue
- 2
- Pages
- 283-288
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W4224245122
- Cited by
- 36
- References
- 5
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.