CoChat

Soft-Copy Mammographic Readings with Different Computer-assisted Detection Cuing Environments: Preliminary Findings

Zheng, Bin, Ganott, Marie A., Britton, Cynthia A., Hakim, Christiane M., Hardesty, Lara A., Chang, Thomas S., Rockette, Howard E., Gur, David · 2001 · Radiology
Cited by 97

The DOI matches its Crossref record.

Abstract

PURPOSE: To assess the performance of radiologists in the detection of masses and microcalcification clusters on digitized mammograms by using different computer-assisted detection (CAD) cuing environments. MATERIALS AND METHODS: Two hundred nine digitized mammograms depicting 57 verified masses and 38 microcalcification clusters in 85 positive and 35 negative cases were interpreted independently by seven radiologists using five display modes. Except for the first mode, for which no CAD results were provided, suspicious regions identified with a CAD scheme were cued in all the other modes by using a combination of two cuing sensitivities (90% and 50%) and two false-positive rates (0.5 and 2.0 per image). A receiver operating characteristic study was performed by using soft-copy images. RESULTS: CAD cuing at 90% sensitivity and a rate of 0.5 false-positive region per image improved observer performance levels significantly (P < .01). As accuracy of CAD cuing decreased so did observer performances (P < .01). Cuing specificity affected mass detection more significantly, while cuing sensitivity affected detection of microcalcification clusters more significantly (P < .01). Reduction of cuing sensitivity and specificity significantly increased false-negative rates in noncued areas (P < .05). Trends were consistent for all observers. CONCLUSION: CAD systems have the potential to significantly improve diagnostic performance in mammography. However, poorly performing schemes could adversely affect observer performance in both cued and noncued areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2213010308

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 97

Metadata

Authors
Zheng, B., Ganott, M. A., Britton, C. A., Hakim, C. M., Hardesty, L. A., Chang, T. S., Rockette, H. E., & Gur, D.
Venue
Radiology
Published
2001-12
Volume
221
Issue
3
Pages
633-640
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2152522287
Cited by
97
References
0
FWCI
7.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Soft-Copy Mammographic Readings with Different Computer-assisted Detection Cuing Environments: Preliminary Findings. https://app.cochat.ai/papers/10.1148/radiol.2213010308
The paper
Zheng, B., Ganott, M. A., Britton, C. A., Hakim, C. M., Hardesty, L. A., Chang, T. S., Rockette, H. E., & Gur, D. (2001). Soft-Copy Mammographic Readings with Different Computer-assisted Detection Cuing Environments: Preliminary Findings. Radiology. https://doi.org/10.1148/radiol.2213010308

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.