The DOI matches its Crossref record.
Testicular Volume: Comparison of Orchidometer and US Measurements in Dogs
Abstract
PURPOSE: To compare the accuracy and precision of orchidometer and ultrasonographic (US) measurements of testicular volume in a canine model. MATERIALS AND METHODS: Volume measurements of 18 canine testes were obtained by using Prader and Rochester orchidometers. Testes were scanned with two linear-array US transducers with imaging frequencies of 6-13 MHz and 5-10 MHz. For each transducer, testicular volumes were calculated by using three formulas: length (L) x width (W) x height (H) x 0.52, L x W(2) x 0.52, and L x W x H x 0.71. Testes were weighed following bilateral orchiectomies. True testicular volume was determined by using the formula volume = weight/density. Paired t tests were used to assess whether mean measurement biases differed significantly from zero. The relationship between true and measured volume was evaluated with a linear regression model. RESULTS: US volume measurements demonstrated lower variability and better linear fit compared with orchidometry (R(2) = 0.75-0.90 vs R(2) = 0.14-0.38). The formula L x W x H x 0.71 had the smallest mean bias relative to true volume with use of either transducer over the entire volume range. CONCLUSION: US methods of testicular volume measurement are more accurate and precise than orchidometry. The formula L x W x H x 0.71 provides a superior estimate of testicular volume and should be used in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Testicular Volume Measurement: Comparison of Ultrasonography, Orchidometry, and Water Displacement
Sakamoto, H., Saito, K., Oohta, M., Inoue, K., Ogawa, Y., & Yoshida, H. (2007) · Urology · doi:10.1016/j.urology.2006.09.012 · Cited by 257
Gregoriou, O., Bakas, P., Grigoriadis, C., Creatsa, M., Hassiakos, D., & Creatsas, G. (2012) · Fertility and Sterility · doi:10.1016/j.fertnstert.2012.04.005 · Cited by 93
Metadata
- Authors
- Paltiel, H. J., Diamond, D. A., Di Canzio, J., Zurakowski, D., Borer, J. G., & Atala, A.
- Venue
- Radiology
- Published
- 2002-01
- Volume
- 222
- Issue
- 1
- Pages
- 114-119
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2065707062
- Cited by
- 200
- References
- 0
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Testicular Volume: Comparison of Orchidometer and US Measurements in Dogs. https://app.cochat.ai/papers/10.1148/radiol.2221001385
- The paper
- Paltiel, H. J., Diamond, D. A., Di Canzio, J., Zurakowski, D., Borer, J. G., & Atala, A. (2002). Testicular Volume: Comparison of Orchidometer and US Measurements in Dogs. Radiology. https://doi.org/10.1148/radiol.2221001385
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.