Testicular Volume: Comparison of Orchidometer and US Measurements in Dogs
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare the accuracy and precision of orchidometer and ultrasonographic (US) measurements of testicular volume in a canine model. MATERIALS AND METHODS: Volume measurements of 18 canine testes were obtained by using Prader and Rochester orchidometers. Testes were scanned with two linear-array US transducers with imaging frequencies of 6-13 MHz and 5-10 MHz. For each transducer, testicular volumes were calculated by using three formulas: length (L) x width (W) x height (H) x 0.52, L x W(2) x 0.52, and L x W x H x 0.71. Testes were weighed following bilateral orchiectomies. True testicular volume was determined by using the formula volume = weight/density. Paired t tests were used to assess whether mean measurement biases differed significantly from zero. The relationship between true and measured volume was evaluated with a linear regression model. RESULTS: US volume measurements demonstrated lower variability and better linear fit compared with orchidometry (R(2) = 0.75-0.90 vs R(2) = 0.14-0.38). The formula L x W x H x 0.71 had the smallest mean bias relative to true volume with use of either transducer over the entire volume range. CONCLUSION: US methods of testicular volume measurement are more accurate and precise than orchidometry. The formula L x W x H x 0.71 provides a superior estimate of testicular volume and should be used in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BEHRE, H. M., NASHAN, D., & NIESCHLAG, E. (1989) · International Journal of Andrology · doi:10.1111/j.1365-2605.1989.tb01328.x · Cited by 219
COMPARATIVE ASSESSMENT OF PEDIATRIC TESTICULAR VOLUME: ORCHIDOMETER VERSUS ULTRASOUND
DIAMOND, D. A., PALTIEL, H. J., DiCANZIO, J., ZURAKOWSKI, D., BAUER, S. B., ATALA, A., EPHRAIM, P. L., GRANT, R., & RETIK, A. B. (2000) · Journal of Urology · doi:10.1016/s0022-5347(05)67264-3 · Cited by 218
Self-citationRepair Versus Observation in Adolescent Varicocele: A Prospective Study
Paduch, D. A., & Niedzielski, J. (1997) · Journal of Urology · doi:10.1016/s0022-5347(01)64403-3 · Cited by 204
Testicular Size: The Effects of Aging, Malnutrition, and Illness
HANDELSMAN, D. J., & STARAJ, S. (1985) · Journal of Andrology · doi:10.1002/j.1939-4640.1985.tb00830.x · Cited by 185
Lenz, S., Giwercman, A., Elsborg, A., Cohr, K.-H., Jelnes, J. E., Carlsen, E., & Skakkebœk, N. E. (1993) · European Urology · doi:10.1159/000474300 · Cited by 167
Takihara, H., Sakatoku, J., Fujii, M., Nasu, T., Cosentino, M., & Cockett, A. T. �. (1983) · Fertility and Sterility · doi:10.1016/s0015-0282(16)47126-8 · Cited by 144
Clinical Measurement of Testicular Volume in Adolescents: Comparison of the Reliability of 5 Methods
Chipkevitch, E., Nishimura, R. T., Tu, D. G. D. S., & Galea, M. (1996) · The Journal of Urology · doi:10.1016/s0022-5347(01)65433-8 · Cited by 97
Wu, F. C. (1993) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.76.1.26 · Cited by 97
Measurement of Testicular Volume: Comparison of 3 Different Methods
Taskinen, S., Taavitsainen, M., & Wikstrom, S. (1996) · Journal of Urology · doi:10.1016/s0022-5347(01)66349-3 · Cited by 91
Accuracy and reproducibility of clinical measures of testicular volume
Rivkees, S. A., Hall, D. A., Boepple, P. A., & Crawford, J. D. (1987) · The Journal of Pediatrics · doi:10.1016/s0022-3476(87)80412-2 · Cited by 91
Cited by
Testicular Volume Measurement: Comparison of Ultrasonography, Orchidometry, and Water Displacement
Sakamoto, H., Saito, K., Oohta, M., Inoue, K., Ogawa, Y., & Yoshida, H. (2007) · Urology · doi:10.1016/j.urology.2006.09.012 · Cited by 257
Gregoriou, O., Bakas, P., Grigoriadis, C., Creatsa, M., Hassiakos, D., & Creatsas, G. (2012) · Fertility and Sterility · doi:10.1016/j.fertnstert.2012.04.005 · Cited by 93
Metadata
- Authors
- Paltiel, H. J., Diamond, D. A., Di Canzio, J., Zurakowski, D., Borer, J. G., & Atala, A.
- Venue
- Radiology
- Published
- 2002-01
- Volume
- 222
- Issue
- 1
- Pages
- 114-119
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2065707062
- Cited by
- 200
- References
- 12
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.