MR Imaging of the Heart with Cine True Fast Imaging with Steady-State Precession: Influence of Spatial and Temporal Resolutions on Left Ventricular Functional Parameters
The DOI matches its Crossref record.
Abstract
The influence of changes in spatial and temporal resolutions on functional parameters in the left ventricle (LV) were investigated with magnetic resonance (MR) imaging with a modified true fast imaging with steady-state precession, or FISP, two-dimensional sequence that provided temporal resolution of 21-90 msec and spatial resolution of 1-3 mm. MR imaging in the heart was performed in 15 healthy volunteers. A decrease in LV functional parameters was observed with reduced spatial and temporal resolutions. The influence of temporal resolution was more relevant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bushby, K., Muntoni, F., & Bourke, J. P. (2003) · Neuromuscular Disorders · doi:10.1016/s0960-8966(02)00213-4 · Cited by 300
Juergens, K. U., Grude, M., Maintz, D., Fallenberg, E. M., Wichter, T., Heindel, W., & Fischbach, R. (2004) · Radiology · doi:10.1148/radiol.2302030042 · Cited by 261
Buechel, E. V., Kaiser, T., Jackson, C., Schmitz, A., & Kellenberger, C. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-19 · Cited by 228
Imaging the right heart: the use of integrated multimodality imaging
Valsangiacomo Buechel, E. R., & Mertens, L. L. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr490 · Cited by 182
“Appropriate spatial and temporal resolution of the images is important for accuracy of the results and can be achieved by adjusting acquisition parameters to the patient’s size and heart rate.(62) Normal ageand gender-specific values for RV volumes and function have been published for the adult and the paediatric popu…”
MethodZhang, J., Chen, J., Cheong, B., Pednekar, A., & Muthupillai, R. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26791 · Cited by 10
“However, the relatively poor temporal resolution (20–30 fps) of the cine SSFP sequence used in routine clinical practice has generally been deemed insufficient for evaluating LV diastolic function.(19,20) For example, Krishnamurthy et al(19) reported that the LV filling and LV ejection rates estimated from LV volume c…”
Method
Metadata
- Authors
- Miller, S., Simonetti, O. P., Carr, J., Kramer, U., & Finn, J. P.
- Venue
- Radiology
- Published
- 2002-04
- Volume
- 223
- Issue
- 1
- Pages
- 263-269
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2030953193
- Cited by
- 178
- References
- 0
- FWCI
- 11.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.