The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Multi–Detector Row CT of Left Ventricular Function with Dedicated Analysis Software versus MR Imaging: Initial Experience
Abstract
PURPOSE: To determine left ventricular (LV) volumetric and functional parameters from retrospectively electrocardiographically gated multi-detector row computed tomography (CT) by using semiautomated analysis software and to correlate results with those of magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 30 patients (mean age, 59.2 years +/- 7.1 [SD]) known to have or suspected of having coronary artery disease, four-channel multi-detector row CT was performed with standard technique, and diastolic and systolic image reconstructions were generated. With commercially available analysis software capable of semiautomated contour detection, end diastolic and end systolic LV volumes were determined from short-axis secondary CT reformations. Steady-state free-precession cine MR images were acquired in short-axis orientation within 48 hours and analyzed by using dedicated software. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MR imaging. RESULTS: Mean end diastolic (138.8 mL +/- 31.9) and end systolic (53.9 mL +/- 21.2) LV volumes as determined with CT correlated well with MR imaging measurements (142.0 mL +/- 32.5 [r = 0.93] and 54.9 mL +/- 22.8 [r = 0.94], respectively [P <.001]). LV ejection fraction (61.6% +/- 10.6 for CT vs 62.3% +/- 10.1 for MR imaging; r = 0.89) and stroke volume (84.6 mL +/- 20.9 for CT vs 86.9 mL +/- 21.5 for MR imaging; r = 0.88) also showed good correlation (P <.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.8% for ejection fraction) without systematic errors. CONCLUSION: In selected patients, semiautomated analysis software enables LV volumetric and functional analysis based on multi-detector row CT data sets, the results of which correlate well with MR imaging findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Ohnesorge, B., Flohr, T., Becker, C., Kopp, A. F., Schoepf, U. J., Baum, U., Knez, A., Klingenbeck-Regn, K., & Reiser, M. F. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv30564 · Cited by 516
Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Pattynama, P. M., Lamb, H. J., van der Velde, E. A., van der Wall, E. E., & de Roos, A. (1993) · Radiology · doi:10.1148/radiology.187.1.8451425 · Cited by 330
Miller, S., Simonetti, O. P., Carr, J., Kramer, U., & Finn, J. P. (2002) · Radiology · doi:10.1148/radiol.2231010235 · Cited by 178
Thiele, H., Paetsch, I., Schnackenburg, B., Bornstedt, A., Grebe, O. C., Wellnhofer, E., Schuler, G. C., Fleck, E., & Nagel, E. C. (2002) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120013298 · Cited by 124
Dirksen, M. S., Bax, J. J., Roos, A., Jukema, J. W., van der Geest, R. J., Geleijns, K., Boersma, E. H., van der Wall, E. E., & Lamb, H. J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02789-3 · Cited by 111
Cottin, Y., Touzery, C., Guy, F., Lalande, A., Ressencourt, O., Roy, S., WALKER, P. M., Louis, P., Brunotte, F., & Wolf, J. E. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv38513 · Cited by 44
Cited by
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Sugeng, L., Mor-Avi, V., Weinert, L., Niel, J., Ebner, C., Steringer-Mascherbauer, R., Schmidt, F., Galuschky, C., Schummers, G., Lang, R. M., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.626143 · Cited by 459
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Valente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
Metadata
- Authors
- Juergens, K. U., Grude, M., Maintz, D., Fallenberg, E. M., Wichter, T., Heindel, W., & Fischbach, R.
- Venue
- Radiology
- Published
- 2004-02
- Volume
- 230
- Issue
- 2
- Pages
- 403-410
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2165684016
- Cited by
- 261
- References
- 9
- FWCI
- 29.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi–Detector Row CT of Left Ventricular Function with Dedicated Analysis Software versus MR Imaging: Initial Experience. https://app.cochat.ai/papers/10.1148/radiol.2302030042
- The paper
- Juergens, K. U., Grude, M., Maintz, D., Fallenberg, E. M., Wichter, T., Heindel, W., & Fischbach, R. (2004). Multi–Detector Row CT of Left Ventricular Function with Dedicated Analysis Software versus MR Imaging: Initial Experience. Radiology. https://doi.org/10.1148/radiol.2302030042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.