Steady-State Blood Volume Measurements in Experimental Tumors with Different Angiogenic Burdens—A Study in Mice
The DOI matches its Crossref record.
Abstract
PURPOSE: To experimentally validate the effectiveness of magnetic resonance (MR) imaging enhanced with long-circulating iron oxide for measurement of vascular volume fractions (VVFs) as indicators of angiogenesis in different experimental tumor models. MATERIALS AND METHODS: Tumors with differing degrees of angiogenesis-9L rodent gliosarcoma, DU4475 human mammary adenocarcinoma, HT1080 human fibrosarcoma, and EOMA hemangioendothelioma--were implanted in nude mice. Tumoral VVFs were measured at submillimeter voxel resolutions by using 1.5-T MR imaging. A technetium-labeled intravascular radiotracer was injected into a subset of the animals to validate the MR imaging measurements. Microvessel density and vascular endothelial growth factor (VEGF) also were measured. Statistical analysis was performed with analysis of variance. RESULTS: High-resolution multisection MR maps of tumor blood volume were obtained in all tumor models. Mean tumoral VVF differed significantly among the different tumors: 2.1% +/- 0.3 (standard error of mean) for 9L gliosarcoma, 3.1% +/- 0.4 for DU4475 mammary adenocarcinoma, 5.5% +/- 0.8 for HT1080 fibrosarcoma, and 6.6% +/- 0.9 for EOMA hemangioendothelioma (P <.01). There was a strong correlation between the MR imaging and radiotracer measurements. There was considerable intra- and intertumoral heterogeneity among the VVFs. MR imaging measurements were in accordance with conventional measurements of angiogenesis, such as microvessel density count and VEGF. CONCLUSION: Measurements of tumoral VVF at high-resolution MR imaging with long-circulating iron oxide are feasible and correlate with angiogenic burden in experimental tumor models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An in vivo correlate of exercise-induced neurogenesis in the adult dentate gyrus
Pereira, A. C., Huddleston, D. E., Brickman, A. M., Sosunov, A. A., Hen, R., McKhann, G. M., Sloan, R., Gage, F. H., Brown, T. R., & Small, S. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611721104 · Cited by 1,353
Imaging of angiogenesis: from microscope to clinic
McDonald, D. M., & Choyke, P. L. (2003) · Nature Medicine · doi:10.1038/nm0603-713 · Cited by 1,016
Imaging Angiogenesis: Applications and Potential for Drug Development
Miller, J. C., Pien, H. H., Sahani, D., Sorensen, A. G., & Thrall, J. H. (2005) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/dji023 · Cited by 325
Current and potential imaging applications of ferumoxytol for magnetic resonance imaging
Toth, G. B., Varallyay, C. G., Horvath, A., Bashir, M. R., Choyke, P. L., Daldrup-Link, H. E., Dosa, E., Finn, J. P., Gahramanov, S., Harisinghani, M., et al. (2017) · Kidney International · doi:10.1016/j.kint.2016.12.037 · Cited by 317
The Progress and Promise of Molecular Imaging Probes in Oncologic Drug Development
Kelloff, G. J., Krohn, K. A., Larson, S. M., Weissleder, R., Mankoff, D. A., Hoffman, J. M., Link, J. M., Guyton, K. Z., Eckelman, W. C., Scher, H. I., et al. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-1302 · Cited by 220
Self-citationNeuwelt, E. A., Várallyay, C. G., Manninger, S., Solymosi, D., Haluska, M., Hunt, M. A., Nesbit, G., Stevens, A., Jerosch-Herold, M., Jacobs, P. M., et al. (2007) · Neurosurgery · doi:10.1227/01.neu.0000255350.71700.37 · Cited by 184
Metadata
- Authors
- Bremer, C., Mustafa, M., Bogdanov, A., Ntziachristos, V., Petrovsky, A., & Weissleder, R.
- Venue
- Radiology
- Published
- 2003-01
- Volume
- 226
- Issue
- 1
- Pages
- 214-220
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1983569280
- Cited by
- 84
- References
- 0
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.