CoChat

Breast Lesions on Sonograms: Computer-aided Diagnosis with Nearly Setting-Independent Features and Artificial Neural Networks

Chen, Chung-Ming, Chou, Yi-Hong, Han, Ko-Chung, Hung, Guo-Shian, Tiu, Chui-Mei, Chiou, Hong-Jen, Chiou, See-Ying · 2003 · Radiology
Cited by 257

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

PURPOSE: To develop a computer-aided diagnosis (CAD) algorithm with setting-independent features and artificial neural networks to differentiate benign from malignant breast lesions. MATERIALS AND METHODS: Two sets of breast sonograms were evaluated. The first set contained 160 lesions and was stored directly on the magnetic optic disks from the ultrasonographic (US) system. Four different boundaries were delineated by four persons for each lesion in the first set. The second set comprised 111 lesions that were extracted from the hard-copy images. Seven morphologic features were used, five of which were newly developed. A multilayer feed-forward neural network was used as the classifier. Reliability, extendability, and robustness of the proposed CAD algorithm were evaluated. Results with the proposed algorithm were compared with those with two previous CAD algorithms. All performance comparisons were based on paired-samples t tests. RESULTS: The area under the receiver operating characteristic curve (A(z)) was 0.952 +/- 0.014 for the first set, 0.982 +/- 0.004 for the first set as the training set and the second set as the prediction set, 0.954 +/- 0.016 for the second set as the training set and the first set as the prediction set, and 0.950 +/- 0.005 for all 271 lesions. At the 5% significance level, the performance of the proposed CAD algorithm was shown to be extendible from one set of US images to the other set and robust for both small and large sample sizes. Moreover, the proposed CAD algorithm was shown to outperform the two previous CAD algorithms in terms of the A(z) value. CONCLUSION: The proposed CAD algorithm could effectively and reliably differentiate benign and malignant lesions. The proposed morphologic features were nearly setting independent and could tolerate reasonable variation in boundary delineation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2262011843

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 257

Metadata

Authors
Chen, C.-M., Chou, Y.-H., Han, K.-C., Hung, G.-S., Tiu, C.-M., Chiou, H.-J., & Chiou, S.-Y.
Venue
Radiology
Published
2003-02
Volume
226
Issue
2
Pages
504-514
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2104999075
Cited by
257
References
16
FWCI
11.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.