The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Radiation Exposure at Chest CT: A Statement of the Fleischner Society
Abstract
The introduction of helical single-detector row computed tomography (CT) and, more recently, multi-detector row CT has greatly increased the clinical indications for CT. Correspondingly, CT examinations now account for greater than one-half of the radiation dose due to medical procedures in the population of North America. The level of CT radiation dose, especially in the pediatric population, is of concern to radiologists, medical physicists, government regulators, and the media. This review addresses this problem with particular reference to radiation dose in chest CT. Specifically it outlines the topics of measurement units used to quantify radiation exposure, factors affecting CT scanner dose efficiency, scanner settings that determine the administered radiation dose, and radiation dose reduction in chest CT. A table of reference dose values is provided. Given the wide variation documented in chest CT radiation exposure, the authors suggest that reference standards be promoted to minimize excessive CT radiation exposure. In addition, further research into the complex relationship between radiation exposure, image quality, and diagnostic accuracy should be encouraged in order to establish the minimum radiation dose necessary to provide adequate diagnostic information for standard clinical questions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The 2007 recommendations of the International Commission on Radiological Protection
Valentin, J. (2007) · Elsevier eBooks · Cited by 4,105
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
International Electrotechnical Commission
Buck, J. (2010) · Handbook of Transnational Economic Governance Regimes · doi:10.1163/ej.9789004163300.i-1081.494 · Cited by 2,742
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
The United Nations Scientific Committee on the Effects of Atomic Radiation
(1965) · Nature · doi:10.1038/206014c0 · Cited by 1,636
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036
Studies of the Mortality of Atomic Bomb Survivors. Report 12, Part I. Cancer: 1950-1990
Pierce, D. A., Shimizu, Y., Preston, D. L., Vaeth, M., & Mabuchi, K. (1996) · Radiation Research · doi:10.2307/3579391 · Cited by 941
CT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 554
A method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
Low-dose CT of the lungs: preliminary observations.
Naidich, D. P., Marshall, C. H., Gribbin, C., Arams, R. S., & McCauley, D. I. (1990) · Radiology · doi:10.1148/radiology.175.3.2343122 · Cited by 339
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Hart, D. B., Jones, D., & Wall, B. F. (1994) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 275
Medical Effects of Ionizing Radiation
Boice, J. D., Miller, R. W., Mettler, F. A., & Upton, A. C. (1995) · Radiation Research · doi:10.2307/3579246 · Cited by 251
Kalender, W. A., Wolf, H., Suess, C., Gies, M., Greess, H., & Bautz, W. A. (1999) · European Radiology · doi:10.1007/s003300050674 · Cited by 245
Greess, H., Wolf, H., Baum, U., Lell, M., Pirkl, M., Kalender, W., & Bautz, W. A. (2000) · European Radiology · doi:10.1007/s003300050062 · Cited by 230
Radiation Exposures to Patients from CT: Reality, Public Perception, and Policy
Nickoloff, E. L., & Alderson, P. O. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770285 · Cited by 220
Rothenberg, L. N., & Pentlow, K. S. (1992) · RadioGraphics · doi:10.1148/radiographics.12.6.1439023 · Cited by 192
Shrimpton, P. C., & Edyvean, S. (1998) · The British Journal of Radiology · doi:10.1259/bjr.71.841.9534691 · Cited by 190
Dosimetry for optimisation of patient protection in computed tomography
Jessen, K. A., Shrimpton, P. C., Geleijns, J., Panzer, W., & Tosi, G. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00024-4 · Cited by 187
The ALARA Concept in Pediatric CT: Myth or Reality?
Slovis, T. L. (2002) · Radiology · doi:10.1148/radiol.2231012100 · Cited by 180
Computer-Simulated Radiation Dose Reduction for Abdominal Multidetector CT of Pediatric Patients
Frush, D. P., Slack, C. C., Hollingsworth, C. L., Bisset, G. S., Donnelly, L. F., Hsieh, J., Lavin-Wensell, T., & Mayo, J. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.5.1791107 · Cited by 174
Self-citationCT of the chest: minimal tube current required for good image quality with the least radiation dose.
Mayo, J. R., Hartman, T. E., Lee, K. S., Primack, S. L., Vedal, S., & Müller, N. L. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.164.3.7863879 · Cited by 154
Self-citationRadiation dose in CT: are we meeting the challenge?
Golding, S. J., & Shrimpton, P. C. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.889.750001 · Cited by 139
Reference Doses for Paediatric Computed Tomography
Shrimpton, P. C., & Wall, B. F. (2000) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a033130 · Cited by 133
Ionizing radiation and cancer risk: evidence from epidemiology
Ron, E. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0672-0 · Cited by 132
Lee, K. S., Primack, S. L., Staples, C. A., et al. (1994) · Radiology · doi:10.1148/radiology.191.3.8184044 · Cited by 119
Haaga, J. R., Miraldi, F. D., MacIntyre, W. J., Lipuma, J. P., Bryan, P. J., & Wiesen, E. (1981) · Radiology · doi:10.1148/radiology.138.2.7455129 · Cited by 107
Lung Cancer Screening: Minimum Tube Current Required for Helical CT
Itoh, S., Ikeda, M., Arahata, S., Kodaira, T., Isomura, T., Kato, T., Yamakawa, K., Maruyama, K., & Ishigaki, T. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap16175 · Cited by 78
Average radiation dose in standard CT examinations of the head: results of the 1990 NEXT survey.
Conway, B. J., McCrohan, J. L., Antonsen, R. G., Rueter, F. G., Slayton, R. J., & Suleiman, O. H. (1992) · Radiology · doi:10.1148/radiology.184.1.1609069 · Cited by 59
Frush, D. P. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0684-9 · Cited by 55
Rogers, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770277 · Cited by 54
Cited by
MacMahon, H., Austin, J. H. M., Gamsu, G., Herold, C. J., Jett, J. R., Naidich, D. P., Patz, E. F., & Swensen, S. J. (2005) · Radiology · doi:10.1148/radiol.2372041887 · Cited by 1,574
Evaluation of Individuals With Pulmonary Nodules: When Is It Lung Cancer?
Gould, M. K., Donington, J., Lynch, W. R., Mazzone, P. J., Midthun, D. E., Naidich, D. P., & Wiener, R. S. (2013) · Chest · doi:10.1378/chest.12-2351 · Cited by 1,450
Interstitial lung disease guideline
Wells, A. U., Hirani, N., & on behalf of the BTS Interstitial Lung Disease Guideline Group, A. S. O. T. B. T. S. S. O. C. C. (2008) · Thorax · doi:10.1136/thx.2008.101691 · Cited by 866
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Bedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201003-0369oc · Cited by 735
Metadata
- Authors
- Mayo, J. R., Aldrich, J., & Müller, N. L.
- Venue
- Radiology
- Published
- 2003-07
- Volume
- 228
- Issue
- 1
- Pages
- 15-21
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2081187499
- Cited by
- 359
- References
- 35
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.