Abstract
PURPOSE: To evaluate a histogram analysis method for differentiating adrenal adenoma from metastasis at computed tomography (CT). MATERIALS AND METHODS: In a retrospective review of 2 years of clinical CT records, 223 adrenal adenomas in 193 patients (115 with contrast material-enhanced CT, 43 with unenhanced and enhanced CT, and 35 with unenhanced CT) and 31 metastases (25 patients with enhanced CT) were found. In 158 patients with adenomas at enhanced CT, diagnosis was based on stable mass size for more than 1 year (n = 135) and characteristic signal intensity decrease at chemical shift magnetic resonance imaging (n = 23). In 35 patients with adenomas at unenhanced CT, mean attenuation was 10 HU or less. Diagnosis of all metastases was based on rapid growth of a mass or new mass in less than 6 months in patients with cancer. Adrenal metastases with extensive necrosis were excluded. Histogram analysis was performed in a circular region of interest (ROI) for mean attenuation, number of pixels, and range of pixel attenuation for all pixels and for the subset of pixels with less than 0 HU ("negative" pixels). Correlation between mean attenuation and percentage negative pixels was calculated. RESULTS: Negative pixels were present in all 74 unenhanced adenomas with mean attenuation of 10 HU or less and in 14 of 16 unenhanced adenomas with mean attenuation above 10 HU. Of 184 enhanced adenomas, only 20 had mean attenuation of 10 HU or less, but 97 contained negative pixels (77 of these 97 masses had mean attenuation above 10 HU). Increase in percentage negative pixels was highly correlated with decrease in mean attenuation of both unenhanced and enhanced adenomas. None of the adrenal metastases had mean attenuation of 10 HU or less or contained negative pixels. CONCLUSION: The histogram method is far more sensitive than the 10-HU threshold method for diagnosis of adrenal adenomas at enhanced CT, with specificity maintained at 100%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature
Boland, G. W., Lee, M. J., Gazelle, G. S., Halpern, E. F., McNicholas, M. M., & Mueller, P. R. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.1.9648789 · Cited by 693
Peña, C. S., Boland, G. W. L., Hahn, P. F., Lee, M. J., & Mueller, P. R. (2000) · Radiology · doi:10.1148/radiology.217.3.r00dc29798 · Cited by 399 · cited 2×
“An alternative method that can be used to characterize an adrenal mass is assessment of the enhancement washout pattern of the mass on 15-minute delayed contrast-enhanced CT scans (9,12).”
MethodDelayed enhanced CT of lipid-poor adrenal adenomas
Caoili, E. M., Korobkin, M., Francis, I. R., Cohan, R. H., & Dunnick, N. R. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.5.1751411 · Cited by 305 · cited 1×
“With this method, the diagnosis of adrenal adenomas has been highly accurate, with a percentage enhancement washout value of 60% or higher (10,12) or a relative percentage washout higher than 40% (10) or 50% (9) at delayed contrast-enhanced CT.”
Method
Cited by
Incidental Adrenal Lesions: Principles, Techniques, and Algorithms for Imaging Characterization
Boland, G. W. L., Blake, M. A., Hahn, P. F., & Mayo-Smith, W. W. (2008) · Radiology · doi:10.1148/radiol.2493070976 · Cited by 381
Lee, G., Lee, H. Y., Park, H., Schiebler, M. L., van Beek, E. J. R., Ohno, Y., Seo, J. B., & Leung, A. (2017) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.09.005 · Cited by 282
Blake, M. A., Kalra, M. K., Sweeney, A. T., Lucey, B. C., Maher, M. M., Sahani, D. V., Halpern, E. F., Mueller, P. R., Hahn, P. F., & Boland, G. W. (2006) · Radiology · doi:10.1148/radiol.2382041514 · Cited by 258
Blake, M. A., Cronin, C. G., & Boland, G. W. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4547 · Cited by 253
Comparison of Unenhanced CT and Chemical Shift MRI in Evaluating Lipid-Rich Adrenal Adenomas
Israel, G. M., Korobkin, M., Wang, C., Hecht, E. N., & Krinsky, G. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.1.1830215 · Cited by 236
Metadata
- Authors
- Bae, K. T., Fuangtharnthip, P., Prasad, S. R., Joe, B. N., & Heiken, J. P.
- Venue
- Radiology
- Published
- 2003-09
- Volume
- 228
- Issue
- 3
- Pages
- 735-742
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2103433396
- Cited by
- 138
- References
- 3
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.