The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Distinguishing Benign from Malignant Adrenal Masses: Multi–Detector Row CT Protocol with 10-Minute Delay
Abstract
PURPOSE: To retrospectively evaluate the accuracy of precontrast attenuation, relative percentage washout (RPW), and absolute percentage washout (APW) in distinguishing benign from malignant adrenal masses at multi-detector row computed tomography (CT). MATERIALS AND METHODS: This HIPAA-compliant retrospective study had institutional review board approval; the need for informed consent was waived. One hundred twenty-two adrenal masses were evaluated in 99 patients (51 men, 48 women; age range, 37-86 years) who had undergone CT performed according to the study protocol and who either were given a pathologic diagnosis or underwent follow-up imaging. Unenhanced images were obtained before administration of 120 mL of an intravenous contrast agent with a 75-second scan delay. Delayed images were obtained after 10 minutes. RPW and APW were computed. Receiver operating characteristic (ROC) analysis was performed to compare mean attenuation and both RPW and APW. Analysis was first performed with the exclusion of pheochromocytomas, myelolipomas, and cysts. Precontrast attenuation criteria specific for benignity or malignancy were determined, and ROC analysis of results for the entire nonpheochromocytoma group was then performed. RESULTS: By using an RPW of 37.5% and excluding cysts and myelolipomas, all malignant lesions were detected with a sensitivity of 100% (17 of 17 lesions) and a specificity of 95% (90 of 95 lesions). Area under the binomial ROC curve (A(z)) values were 0.912, 0.985, and 0.892 for precontrast attenuation, RPW, and APW, respectively. Precontrast attenuation of less than 0 or more than 43 HU indicated benign and malignant entities, respectively. Incorporation of these criteria into the APW analysis yielded a sensitivity of 100% (17 of 17 lesions) and a specificity of 98% (93 of 95 lesions) for a threshold washout value of 52.0%. This attenuation-corrected APW generated the greatest A(z) value (ie, 0.988). Combining all the information available from the protocol yielded a sensitivity of 100% (17 of 17 lesions) and a specificity of 98% (98 of 100 lesions) for differentiating benign from malignant masses. CONCLUSION: Precontrast attenuation of less than 0 HU supercedes the washout profile in the evaluation of an individual adrenal mass. Noncalcified, nonhemorrhagic adrenal lesions with precontrast attenuation of more than 43 HU should be considered suspicious for malignancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature
Boland, G. W., Lee, M. J., Gazelle, G. S., Halpern, E. F., McNicholas, M. M., & Mueller, P. R. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.1.9648789 · Cited by 693
Self-citationAdrenal Masses: Characterization with Combined Unenhanced and Delayed Enhanced CT
Caoili, E. M., Korobkin, M., Francis, I. R., Cohan, R. H., Platt, J. F., Dunnick, N. R., & Raghupathi, K. I. (2002) · Radiology · doi:10.1148/radiol.2223010766 · Cited by 690
Peña, C. S., Boland, G. W. L., Hahn, P. F., Lee, M. J., & Mueller, P. R. (2000) · Radiology · doi:10.1148/radiology.217.3.r00dc29798 · Cited by 399
Self-citationCT time-attenuation washout curves of adrenal adenomas and nonadenomas
Korobkin, M., Brodeur, F. J., Francis, I. R., Quint, L. E., Dunnick, N. R., & Londy, F. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.3.9490968 · Cited by 386
Differentiation of adrenal adenomas from nonadenomas using CT attenuation values.
Korobkin, M., Brodeur, F. J., Yutzy, G. G., Francis, I. R., Quint, L. E., Dunnick, N. R., & Kazerooni, E. A. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.3.8623622 · Cited by 365
State-of-the-Art Adrenal Imaging
Mayo-Smith, W. W., Boland, G. W., Noto, R. B., & Lee, M. J. (2001) · RadioGraphics · doi:10.1148/radiographics.21.4.g01jl21995 · Cited by 359
Self-citationImaging of Adrenal Incidentalomas: Current Status
Dunnick, N. R., & Korobkin, M. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.3.1790559 · Cited by 307
Delayed enhanced CT of lipid-poor adrenal adenomas
Caoili, E. M., Korobkin, M., Francis, I. R., Cohan, R. H., & Dunnick, N. R. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.5.1751411 · Cited by 305
Chemical Shift MR Imaging of Hyperattenuating (>10 HU) Adrenal Masses: Does It Still Have a Role?
Haider, M. A., Ghai, S., Jhaveri, K., & Lockwood, G. (2004) · Radiology · doi:10.1148/radiol.2313030676 · Cited by 278
Boland, G. W., Goldberg, M. A., Lee, M. J., Mayo-Smith, W. W., Dixon, J., McNicholas, M. M., & Mueller, P. R. (1995) · Radiology · doi:10.1148/radiology.194.1.7997539 · Cited by 223
Self-citation
Cited by
Lacroix, A., Feelders, R. A., Stratakis, C. A., & Nieman, L. K. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61375-1 · Cited by 1,777
Fassnacht, M., Arlt, W., Bancos, I., Dralle, H., Newell-Price, J., Sahdev, A., Tabarin, A., Terzolo, M., Tsagarakis, S., & Dekkers, O. M. (2016) · European Journal of Endocrinology · doi:10.1530/eje-16-0467 · Cited by 1,566
Fassnacht, M., Dekkers, O. M., Else, T., Baudin, E., Berruti, A., de Krijger, R. R., Haak, H. R., Mihai, R., Assie, G., & Terzolo, M. (2018) · European Journal of Endocrinology · doi:10.1530/eje-18-0608 · Cited by 961
Fassnacht, M., Tsagarakis, S., Terzolo, M., Tabarin, A., Sahdev, A., Newell-Price, J., Pelsma, I., Marina, L., Lorenz, K., Bancos, I., et al. (2023) · European Journal of Endocrinology · doi:10.1093/ejendo/lvad066 · Cited by 786
Song, J. H., Chaudhry, F. S., & Mayo-Smith, W. W. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2799 · Cited by 579
Metadata
- Authors
- Blake, M. A., Kalra, M. K., Sweeney, A. T., Lucey, B. C., Maher, M. M., Sahani, D. V., Halpern, E. F., Mueller, P. R., Hahn, P. F., & Boland, G. W.
- Venue
- Radiology
- Published
- 2006-02
- Volume
- 238
- Issue
- 2
- Pages
- 578-585
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2166319538
- Cited by
- 258
- References
- 23
- FWCI
- 14.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distinguishing Benign from Malignant Adrenal Masses: Multi–Detector Row CT Protocol with 10-Minute Delay. https://app.cochat.ai/papers/10.1148/radiol.2382041514
- The paper
- Blake, M. A., Kalra, M. K., Sweeney, A. T., Lucey, B. C., Maher, M. M., Sahani, D. V., Halpern, E. F., Mueller, P. R., Hahn, P. F., & Boland, G. W. (2006). Distinguishing Benign from Malignant Adrenal Masses: Multi–Detector Row CT Protocol with 10-Minute Delay. Radiology. https://doi.org/10.1148/radiol.2382041514
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.