Pulmonary Nodules at Chest CT: Effect of Computer-aided Diagnosis on Radiologists’ Detection Performance
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the effect of computer-aided diagnosis (CAD) on radiologists' detection of pulmonary nodules. MATERIALS AND METHODS: Fifty chest computed tomographic (CT) examination cases were used. The mean nodule size was 0.81 cm +/- 0.60 (SD) (range, 0.3-2.9 cm). Alternative free-response receiver operating characteristic (ROC) analysis with a continuous rating scale was used to compare the observers' performance in detecting nodules with and without use of CAD. Five board-certified radiologists and five radiology residents participated in an observer performance study. First they were asked to rate the probability of nodule presence without using CAD; then they were asked to rate the probability of nodule presence by using CAD. RESULTS: For all radiologists, the mean areas under the best-fit alternative free-response ROC curves (Az) without and with CAD were 0.64 +/- 0.08 and 0.67 +/- 0.09, respectively, indicating a significant difference (P <.01). For the five board-certified radiologists, the mean Az values without and with CAD were 0.63 +/- 0.08 and 0.66 +/- 0.09, respectively, indicating a significant difference (P <.01). For the five resident radiologists, the mean Az values without and with CAD were 0.66 +/- 0.04 and 0.68 +/- 0.04, respectively, indicating a significant difference (P =.02). At observer performance analyses, there were no significant differences in Az values obtained either without (P =.61) or with (P =.88) CAD between the board-certified radiologists and the residents. For all radiologists, in the detection of pulmonary nodules 1.0 cm in diameter or smaller, the mean Az values without and with CAD were 0.60 +/- 0.11 and 0.64 +/- 0.11, respectively, indicating a significant difference (P <.01). CONCLUSION: Use of the CAD system improved the board-certified radiologists' and residents' detection of pulmonary nodules at chest CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 831
Screening for Early Lung Cancer with Low-Dose Spiral CT: Prevalence in 817 Asymptomatic Smokers
Diederich, S., Wormanns, D., Semik, M., Thomas, M., Lenzen, H., Roos, N., & Heindel, W. L. (2002) · Radiology · doi:10.1148/radiol.2223010490 · Cited by 523
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Computerized Detection of Pulmonary Nodules on CT Scans
Armato, S. G., Giger, M. L., Moran, C. J., Blackburn, J. T., Doi, K., & MacMahon, H. (1999) · Radiographics · doi:10.1148/radiographics.19.5.g99se181303 · Cited by 380
Free-response methodology: alternate analysis and a new observer-performance experiment.
Chakraborty, D. P., & Winter, L. H. (1990) · Radiology · doi:10.1148/radiology.174.3.2305073 · Cited by 363
Lung Cancer Screening Using Low-Dose Spiral CT
Nawa, T., Nakagawa, T., Kusano, S., Kawasaki, Y., Sugawara, Y., & Nakata, H. (2002) · Chest · doi:10.1378/chest.122.1.15 · Cited by 315
Kobayashi, T., Xu, X. W., MacMahon, H., Metz, C. E., & Doi, K. (1996) · Radiology · doi:10.1148/radiology.199.3.8638015 · Cited by 244
Computerized Detection of Pulmonary Nodules in Computed Tomography Images
GIGER, M. L., BAE, K. T., & MacMAHON, H. (1994) · Investigative Radiology · doi:10.1097/00004424-199404000-00013 · Cited by 200
Cited by
Biomarkers in Cancer Staging, Prognosis and Treatment Selection
Ludwig, J. A., & Weinstein, J. N. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1739 · Cited by 1,666
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2017027 · Cited by 297
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Mansoor, A., Bagci, U., Foster, B., Xu, Z., Papadakis, G. Z., Folio, L. R., Udupa, J. K., & Mollura, D. J. (2015) · RadioGraphics · doi:10.1148/rg.2015140232 · Cited by 265
Firmino, M., Angelo, G., Morais, H., Dantas, M. R., & Valentim, R. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0120-7 · Cited by 252
“According to Awai et al. [4], the detection rate for lung cancer using CT is 2.6–10 times greater than using analog radiography.”
InfluentialComputed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Song, Y., Zhang, Y., Yan, X., Liu, H., Zhou, M., Hu, B., & Yang, G. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26047 · Cited by 186
Lung cancer prediction using machine learning and advanced imaging techniques
Kadir, T., & Gleeson, F. (2018) · Translational Lung Cancer Research · doi:10.21037/tlcr.2018.05.15 · Cited by 171
“Indeed, computer assisted approaches have been shown to improve consistency between physicians in a variety of clinical contexts, including nodule detection (4) and mammography screening (5) and one might expect such decision support tools could provide the same benefit in nodule classification .”
BackgroundZheng, S., Guo, J., Cui, X., Veldhuis, R. N. J., Oudkerk, M., & van Ooijen, P. M. A. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2935553 · Cited by 167
“It also helps to improve the accuracy of lung nodule detection as well as to reduce the number of missed nodules and misdiagnosis [5].”
BackgroundImproving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Li, D., Pehrson, L. M., Lauridsen, C. A., Tøttrup, L., Fraccaro, M., Elliott, D., Zając, H. D., Darkner, S., Carlsen, J. F., & Nielsen, M. B. (2021) · Diagnostics · doi:10.3390/diagnostics11122206 · Cited by 35
Metadata
- Authors
- Awai, K., Murao, K., Ozawa, A., Komi, M., Hayakawa, H., Hori, S., & Nishimura, Y.
- Venue
- Radiology
- Published
- 2004-02
- Volume
- 230
- Issue
- 2
- Pages
- 347-352
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2048561164
- Cited by
- 272
- References
- 11
- FWCI
- 17.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.