CoChat

Sensitivity of Noncommercial Computer-aided Detection System for Mammographic Breast Cancer Detection: Pilot Clinical Trial

Open access
Helvie, Mark A., Hadjiiski, Lubomir, Makariou, Erini, Chan, Heang-Ping, Petrick, Nicholas, Sahiner, Berkman, Lo, Shih-Chung B., Freedman, Matthew, Adler, Dorit, Bailey, Janet, Blane, Caroline, Hoff, Donna, Hunt, Karen, Joynt, Lynn, Klein, Katherine, Paramagul, Chintana, Patterson, Stephanie K., Roubidoux, Marilyn A. · 2004 · Radiology
Cited by 101

The DOI matches its Crossref record.

Abstract

PURPOSE: To evaluate a noncommercial computer-aided detection (CAD) program for breast cancer detection with screening mammography. MATERIALS AND METHODS: A CAD program was developed for mammographic breast cancer detection. The program was applied to 2,389 patients' screening mammograms at two geographically remote academic institutions (institutions A and B). Thirteen radiologists who specialized in breast imaging participated in this pilot study. For each case, the individual radiologist performed a prospective Breast Imaging Reporting and Data System (BI-RADS) assessment after viewing of the screening mammogram. Subsequently, the radiologist was shown CAD results and rendered a second BI-RADS assessment by using knowledge of both mammographic appearance and CAD results. Outcome analysis of results of examination in patients recalled for a repeat examination, of biopsy, and of 1-year follow-up examination was recorded. Correct detection with CAD included a computer-generated mark indicating a possible malignancy on craniocaudal or mediolateral oblique views or both. RESULTS: Eleven (0.46%) of 2,389 patients had mammographically detected nonpalpable breast cancers. Ten (91%) of 11 (95% CI: 74%, 100%) cancers were correctly identified with CAD. Radiologist sensitivity without CAD was 91% (10 of 11; 95% CI: 74%, 100%). In 1,077 patients, follow-up findings were documented at 1 year. Five (0.46%) patients developed cancers, which were found on subsequent screening mammograms. The area where the cancers developed in two (40%) of these five patients was marked (true-positive finding) by the computer in the preceding year. Because of CAD results, a 9.7% increase in recall rate from 14.4% (344 of 2,389) to 15.8% (378 of 2,389) occurred. Radiologists' recall rate of study patients prior to use of CAD was 31% higher than the average rate for nonstudy cases (10.3%) during the same time period at institution A. CONCLUSION: Performance of the CAD program had a very high sensitivity of 91% (95% CI: 74%, 100%).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2311030429

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Helvie, M. A., Hadjiiski, L., Makariou, E., Chan, H.-P., Petrick, N., Sahiner, B., Lo, S.-C. B., Freedman, M., Adler, D., Bailey, J., Blane, C., Hoff, D., Hunt, K., Joynt, L., Klein, K., Paramagul, C., Patterson, S. K., & Roubidoux, M. A.
Venue
Radiology
Published
2004-04
Volume
231
Issue
1
Pages
208-214
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2100684166
Cited by
101
References
0
FWCI
13.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.