Feasibility of Using the Privacy-preserving Large Language Model Vicuna for Labeling Radiology Reports
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background Large language models (LLMs) such as ChatGPT, though proficient in many text-based tasks, are not suitable for use with radiology reports due to patient privacy constraints. Purpose To test the feasibility of using an alternative LLM (Vicuna-13B) that can be run locally for labeling radiography reports. Materials and Methods Chest radiography reports from the MIMIC-CXR and National Institutes of Health (NIH) data sets were included in this retrospective study. Reports were examined for 13 findings. Outputs reporting the presence or absence of the 13 findings were generated by Vicuna by using a single-step or multistep prompting strategy (prompts 1 and 2, respectively). Agreements between Vicuna outputs and CheXpert and CheXbert labelers were assessed using Fleiss κ. Agreement between Vicuna outputs from three runs under a hyperparameter setting that introduced some randomness (temperature, 0.7) was also assessed. The performance of Vicuna and the labelers was assessed in a subset of 100 NIH reports annotated by a radiologist with use of area under the receiver operating characteristic curve (AUC). Results A total of 3269 reports from the MIMIC-CXR data set (median patient age, 68 years [IQR, 59–79 years]; 161 male patients) and 25 596 reports from the NIH data set (median patient age, 47 years [IQR, 32–58 years]; 1557 male patients) were included. Vicuna outputs with prompt 2 showed, on average, moderate to substantial agreement with the labelers on the MIMIC-CXR (κ median, 0.57 [IQR, 0.45–0.66] with CheXpert and 0.64 [IQR, 0.45–0.68] with CheXbert) and NIH (κ median, 0.52 [IQR, 0.41–0.65] with CheXpert and 0.55 [IQR, 0.41–0.74] with CheXbert) data sets, respectively. Vicuna with prompt 2 performed at par (median AUC, 0.84 [IQR, 0.74–0.93]) with both labelers on nine of 11 findings. Conclusion In this proof-of-concept study, outputs of the LLM Vicuna reporting the presence or absence of 13 findings on chest radiography reports showed moderate to substantial agreement with existing labelers. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Cai in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
High agreement but low Kappa: I. the problems of two paradoxes
Feinstein, A. R., & Cicchetti, D. V. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90158-l · Cited by 3,034
MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reports
Johnson, A. E. W., Pollard, T. J., Berkowitz, S. J., Greenbaum, N. R., Lungren, M. P., Deng, C.-Y., Mark, R. G., & Horng, S. (2019) · Scientific Data · doi:10.1038/s41597-019-0322-0 · Cited by 1,816
Adams, L. C., Truhn, D., Busch, F., Kader, A., Niehues, S. M., Makowski, M. R., & Bressem, K. K. (2023) · Radiology · doi:10.1148/radiol.230725 · Cited by 339
Exploring Large-scale Public Medical Image Datasets
Oakden-Rayner, L. (2020) · Academic Radiology · doi:10.1016/j.acra.2019.10.006 · Cited by 250
Appropriateness of breast cancer prevention and screening recommendations provided by ChatGPT
Haver, H. L., Ambinder, E. B., Bahl, M., Oluyemi, E. T., Jeudy, J., & Yi, P. H. (2023) · Radiology · doi:10.1148/radiol.230424 · Cited by 247
Peng, B., Li, C., He, P., Galley, M., & Gao, J. (2023) · arXiv · doi:10.48550/arxiv.2304.03277 · Cited by 183
NegBio: a high-performance tool for negation and uncertainty detection in radiology reports
Peng, Y., Wang, X., Lu, L., Bagheri, M., Summers, R., & Lu, Z. (2017) · arXiv · doi:10.48550/arxiv.1712.05898 · Cited by 175
Self-citationSelf-Instruct: Aligning Language Models with Self-Generated Instructions
Wang, Y., Kordi, Y., Mishra, S., Liu, A., Smith, N. A., Khashabi, D., & Hajishirzi, H. (2022) · arXiv · doi:10.48550/arxiv.2212.10560 · Cited by 118
Cited by
Bhayana, R. (2024) · Radiology · doi:10.1148/radiol.232756 · Cited by 329
Moulaei, K., Yadegari, A., Baharestani, M., Farzanbakhsh, S., Sabet, B., & Reza Afrash, M. (2024) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2024.105474 · Cited by 244
Le Guellec, B., Lefèvre, A., Geay, C., Shorten, L., Bruge, C., Hacein-Bey, L., Amouyel, P., Pruvo, J.-P., Kuchcinski, G., & Hamroun, A. (2024) · Radiology: Artificial Intelligence · doi:10.1148/ryai.230364 · Cited by 115
“A recent study assessed the ability of Vicuna to extract findings from chest radiograph reports from a publicly available database (14).”
BackgroundHuang, Y., Wu, R., He, J., & Xiang, Y. (2024) · Journal of Global Health · doi:10.7189/jogh.14.04070 · Cited by 72
“…can be addressed through de-identification and anonymisation to reduce the risk of personal identity information leakage, or by employing differential privacy techniques that introduce random noise, thereby protecting individual information while allowing for analysis of population data [43–45].”
BackgroundDevelopment and Evaluation of a Retrieval-Augmented Large Language Model Framework for Ophthalmology
Luo, M.-J., Pang, J., Bi, S., Lai, Y., Zhao, J., Shang, Y., Cui, T., Yang, Y., Lin, Z., Zhao, L., et al. (2024) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2024.2513 · Cited by 70
Metadata
- Authors
- Mukherjee, P., Hou, B., Lanfredi, R. B., & Summers, R. M.
- Venue
- Radiology
- Published
- 2023-10-01
- Volume
- 309
- Issue
- 1
- Pages
- e231147-e231147
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W4387472906
- Cited by
- 114
- References
- 10
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.