Myocardial Perfusion and MR Angiography of Chest with SH U 555 C: Results of Placebo-controlled Clinical Phase I Study

Reimer, Peter, Bremer, Christoph, Allkemper, Thomas, Engelhardt, Matthias, Mahler, Marianne, Ebert, Wolfgang, Tombach, Bernd · 2004 · Radiology
Cited by 49

The DOI matches its Crossref record.

Abstract

PURPOSE: To evaluate SH U 555 C for contrast material-enhanced three-dimensional magnetic resonance (MR) angiography of the chest and myocardial perfusion. MATERIALS AND METHODS: For chest MR angiography, SH U 555 C was intravenously injected at four doses (5, 10, 20, and 40 micromol iron [Fe] per kilogram of body weight) into three healthy volunteers per dose group, and placebo (saline) was injected into one additional volunteer per dose group (16 subjects). With a body phased-array coil, serial high-spatial-resolution breath-hold three-dimensional MR angiography of the chest was performed at baseline, first pass, and 6, 12, 18, 24, 30, 36, and 42 minutes after injection. SH U 555 C (40 micromol Fe/kg) was injected into four additional volunteers to evaluate cardiac perfusion. Signal intensity (SI) was measured in vessels, cardiac chambers, and myocardium to calculate relative SI changes during time. Analysis of variance for multiple comparisons was applied for statistical analysis. Two readers assessed image quality. Subjects were monitored for side effects (cardiovascular reactions) for 24 hours. RESULTS: SH U 555 C showed a dose-dependent increase in SI enhancement during first pass and equilibrium phase. SH U 555 C showed dose-dependent increase (range, 259% +/- 160 [SD] at 5 micromol Fe/kg to 907% +/- 370 at 40 micromol Fe/kg) for thoracic aorta during first pass. Intravascular SI did not significantly decrease with time during equilibrium phase within arterial and venous vessels. Image quality remained stable and was diagnostic for highest dose group to 30 minutes, with good to excellent contrast even in smaller blood vessels. For cardiac perfusion, SH U 555 C showed peak enhancement during first pass through right and left ventricles, as well as stable SI during equilibrium phase within cardiac chambers and myocardium. Peak enhancement during first pass was limited due to susceptibility effects, which were more pronounced in right ventricle than in left. Contrast agent was well tolerated, and no cardiovascular reactions occurred. CONCLUSION: SH U 555 C bolus injected at highest dose of 40 micromol Fe/kg has capability for depiction at first-pass MR angiography and for cardiac perfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2312021251

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 49

Metadata

Authors
Reimer, P., Bremer, C., Allkemper, T., Engelhardt, M., Mahler, M., Ebert, W., & Tombach, B.
Venue
Radiology
Published
2004-05
Volume
231
Issue
2
Pages
474-481
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1966228017
Cited by
49
References
0
FWCI
4.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Myocardial Perfusion and MR Angiography of Chest with SH U 555 C: Results of Placebo-controlled Clinical Phase I Study. https://app.cochat.ai/papers/10.1148/radiol.2312021251
The paper
Reimer, P., Bremer, C., Allkemper, T., Engelhardt, M., Mahler, M., Ebert, W., & Tombach, B. (2004). Myocardial Perfusion and MR Angiography of Chest with SH U 555 C: Results of Placebo-controlled Clinical Phase I Study. Radiology. https://doi.org/10.1148/radiol.2312021251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.