CoChat

The Image Biomarker Standardization Initiative: Standardized Convolutional Filters for Reproducible Radiomics and Enhanced Clinical Insights

Open access
Whybra, Philip, Zwanenburg, Alex, Andrearczyk, Vincent, Schaer, Roger, Apte, Aditya P., Ayotte, Alexandre, Baheti, Bhakti, Bakas, Spyridon, Bettinelli, Andrea, Boellaard, Ronald, Boldrini, Luca, Buvat, Irène, Cook, Gary J. R., Dietsche, Florian, Dinapoli, Nicola, Gabryś, Hubert S., Goh, Vicky, Guckenberger, Matthias, Hatt, Mathieu, Hosseinzadeh, Mahdi, Iyer, Aditi, Lenkowicz, Jacopo, Loutfi, Mahdi A. L., Löck, Steffen, Marturano, Francesca, Morin, Olivier, Nioche, Christophe, Orlhac, Fanny, Pati, Sarthak, Rahmim, Arman, Rezaeijo, Seyed Masoud, Rookyard, Christopher G., Salmanpour, Mohammad R., Schindele, Andreas, Shiri, Isaac, Spezi, Emiliano, Tanadini-Lang, Stephanie, Tixier, Florent, Upadhaya, Taman, Valentini, Vincenzo, van Griethuysen, Joost J. M., Yousefirizi, Fereshteh, Zaidi, Habib, Müller, Henning, Vallières, Martin, Depeursinge, Adrien · 2024 · Radiology
Cited by 239

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Filters are commonly used to enhance specific structures and patterns in images, such as vessels or peritumoral regions, to enable clinical insights beyond the visible image using radiomics. However, their lack of standardization restricts reproducibility and clinical translation of radiomics decision support tools. In this special report, teams of researchers who developed radiomics software participated in a three-phase study (September 2020 to December 2022) to establish a standardized set of filters. The first two phases focused on finding reference filtered images and reference feature values for commonly used convolutional filters: mean, Laplacian of Gaussian, Laws and Gabor kernels, separable and nonseparable wavelets (including decomposed forms), and Riesz transformations. In the first phase, 15 teams used digital phantoms to establish 33 reference filtered images of 36 filter configurations. In phase 2, 11 teams used a chest CT image to derive reference values for 323 of 396 features computed from filtered images using 22 filter and image processing configurations. Reference filtered images and feature values for Riesz transformations were not established. Reproducibility of standardized convolutional filters was validated on a public data set of multimodal imaging (CT, fluorodeoxyglucose PET, and T1-weighted MRI) in 51 patients with soft-tissue sarcoma. At validation, reproducibility of 486 features computed from filtered images using nine configurations × three imaging modalities was assessed using the lower bounds of 95% CIs of intraclass correlation coefficients. Out of 486 features, 458 were found to be reproducible across nine teams with lower bounds of 95% CIs of intraclass correlation coefficients greater than 0.75. In conclusion, eight filter types were standardized with reference filtered images and reference feature values for verifying and calibrating radiomics software packages. A web-based tool is available for compliance checking.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.231319

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 239

Metadata

Authors
Whybra, P., Zwanenburg, A., Andrearczyk, V., Schaer, R., Apte, A. P., Ayotte, A., Baheti, B., Bakas, S., Bettinelli, A., Boellaard, R., Boldrini, L., Buvat, I., Cook, G. J. R., Dietsche, F., Dinapoli, N., Gabryś, H. S., Goh, V., Guckenberger, M., Hatt, M., Hosseinzadeh, M., Iyer, A., Lenkowicz, J., Loutfi, M. A. L., Löck, S., Marturano, F., Morin, O., Nioche, C., Orlhac, F., Pati, S., Rahmim, A., Rezaeijo, S. M., Rookyard, C. G., Salmanpour, M. R., Schindele, A., Shiri, I., Spezi, E., Tanadini-Lang, S., Tixier, F., Upadhaya, T., Valentini, V., van Griethuysen, J. J. M., Yousefirizi, F., Zaidi, H., Müller, H., Vallières, M., & Depeursinge, A.
Venue
Radiology
Published
2024-02-01
Volume
310
Issue
2
Pages
e231319-e231319
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W4391577343
Cited by
239
References
10
FWCI
54.73
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Image Biomarker Standardization Initiative: Standardized Convolutional Filters for Reproducible Radiomics and Enhanced Clinical Insights. https://app.cochat.ai/papers/10.1148/radiol.231319
The paper
Whybra, P., Zwanenburg, A., Andrearczyk, V., Schaer, R., Apte, A. P., Ayotte, A., Baheti, B., Bakas, S., Bettinelli, A., Boellaard, R., Boldrini, L., Buvat, I., Cook, G. J. R., Dietsche, F., Dinapoli, N., Gabryś, H. S., Goh, V., Guckenberger, M., Hatt, M., . . . Depeursinge, A. (2024). The Image Biomarker Standardization Initiative: Standardized Convolutional Filters for Reproducible Radiomics and Enhanced Clinical Insights. Radiology. https://doi.org/10.1148/radiol.231319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.