The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Patient Radiation Dose at CT Urography and Conventional Urography
Abstract
PURPOSE: To measure and compare patient radiation dose from computed tomographic (CT) urography and conventional urography and to compare these doses with dose estimates determined from phantom measurements. MATERIALS AND METHODS: Patient skin doses were determined by placing a thermoluminescent dosimeter (TLD) strip (six TLD chips) on the abdomen of eight patients examined with CT urography and 11 patients examined with conventional urography. CT urography group consisted of two women and six men (mean age, 55.5 years), and conventional urography group consisted of six women and five men (mean age, 58.9 years). CT urography protocol included three volumetric acquisitions of the abdomen and pelvis. Conventional urography protocol consisted of acquisition of several images involving full nephrotomography and oblique projections. Mean and SD of measured patient doses were compared with corresponding calculated doses and with dose measured on a Lucite pelvic-torso phantom. Correlation coefficient (R(2)) was calculated to compare measured and calculated skin doses for conventional urography examination, and two-tailed P value significance test was used to evaluate variation in effective dose with patient size. Radiation risk was calculated from effective dose estimates. RESULTS: Mean patient skin doses for CT urography measured with TLD strips and calculated from phantom data (CT dose index) were 56.3 mGy +/- 11.5 and 54.6 mGy +/- 4.1, respectively. Mean patient skin doses for conventional urography measured with TLD strips and calculated as entrance skin dose were 151 mGy +/- 90 and 145 mGy +/- 76, respectively. Correlation coefficient between measured and calculated skin doses for conventional urography examinations was 0.95. Mean effective dose estimates for CT urography and conventional urography were 14.8 mSv +/- 90.0 and 9.7 mSv +/- 3.0, respectively. Mean effective doses estimated for the pelvic-torso phantom were 15.9 mSv (CT urography) and 7.8 mSv (conventional urography). CONCLUSION: Standard protocol for CT urography led to higher mean effective dose, approximately 1.5 times the radiation risk for conventional urography. Patient dose estimates should be taken into consideration when imaging protocols are established for CT urography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Cited by
Rehani, M. M., Ciraj-Bjelac, O., Vañó, E., Miller, D. L., Walsh, S., Giordano, B. D., & Persliden, J. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2012.03.001 · Cited by 344
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
What Is the Current Role of CT Urography and MR Urography in the Evaluation of the Urinary Tract?
Silverman, S. G., Leyendecker, J. R., & Amis, E. S. (2009) · Radiology · doi:10.1148/radiol.2502080534 · Cited by 298
Self-citationNATIONAL DIAGNOSTIC REFERENCE LEVEL INITIATIVE FOR COMPUTED TOMOGRAPHY EXAMINATIONS IN KENYA
Korir, G. K., Wambani, J. S., Korir, I. K., Tries, M. A., & Boen, P. K. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv020 · Cited by 52
Metadata
- Authors
- Nawfel, R. D., Judy, P. F., Schleipman, A. R., & Silverman, S. G.
- Venue
- Radiology
- Published
- 2004-07
- Volume
- 232
- Issue
- 1
- Pages
- 126-132
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2146204128
- Cited by
- 163
- References
- 1
- FWCI
- 9.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.