The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
What Is the Current Role of CT Urography and MR Urography in the Evaluation of the Urinary Tract?
Abstract
Technologic advances in both computed tomography (CT) and magnetic resonance (MR) imaging have resulted in the ability to image the urinary tract in ways that surpass the prior mainstay of urinary tract imaging, the intravenous urogram. In adults, for most, if not all, historical indications for intravenous urography, CT urography or MR urography is now the preferred examination. Although a variety of techniques for both examinations have been described, each test provides more diagnostic information than does intravenous urography. With the introduction of multidetector technology, CT urography, to date, has emerged as the initial heir apparent to intravenous urography; many years of experience have now clearly demonstrated that CT is the test of choice for many urologic problems, including urolithiasis, renal masses, urinary tract infection, trauma, and obstructive uropathy. CT urography provides a detailed anatomic depiction of each of the major portions of the urinary tract--the kidneys, intrarenal collecting systems, ureters, and bladder--and thus allows patients with hematuria to be evaluated comprehensively. MR urography can be used also to evaluate the urinary tract and has the advantage of not using ionizing radiation and the potential to provide more functional information than CT. However, MR urography is less established and less reliably results in diagnostic image quality relative to CT urography. Although both tests can be used to evaluate the urinary tract, several issues remain and include reaching a consensus on the optimal protocols and appropriate utilization in an era of cost containment and heightened concerns about radiation exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
Self-citationACR Guidance Document for Safe MR Practices: 2007
Kanal, E., Barkovich, A. J., Bell, C., Borgstede, J. P., Bradley, W. G., Froelich, J. W., Gilk, T., Gimbel, J. R., Gosbee, J., Kuhni-Kaminski, E., et al. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1616 · Cited by 787
Acute flank pain: comparison of non-contrast-enhanced CT and intravenous urography.
Smith, R. C., Rosenfield, A. T., Choe, K. A., Essenmacher, K. R., Verga, M., Glickman, M. G., & Lange, R. C. (1995) · Radiology · doi:10.1148/radiology.194.3.7862980 · Cited by 671
Diagnosis of acute flank pain: value of unenhanced helical CT.
Smith, R. C., Verga, M., McCarthy, S., & Rosenfield, A. T. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.1.8571915 · Cited by 580
Management of the Incidental Renal Mass
Silverman, S. G., Israel, G. M., Herts, B. R., & Richie, J. P. (2008) · Radiology · doi:10.1148/radiol.2491070783 · Cited by 434
Self-citationBosniak, M. A. (1991) · Radiology · doi:10.1148/radiology.179.2.2014269 · Cited by 299
Urinary Tract Abnormalities: Initial Experience with Multi–Detector Row CT Urography
Caoili, E. M., Cohan, R. H., KOROBKIN, M. T., Platt, J. F., Francis, I. R., Faerber, G. J., Montie, J. E., & Ellis, J. H. (2002) · Radiology · doi:10.1148/radiol.2222010667 · Cited by 288
Cited by
Diagnosis, Evaluation and Follow-Up of Asymptomatic Microhematuria (AMH) in Adults: AUA Guideline
Davis, R., Jones, J. S., Barocas, D. A., Castle, E. P., Lang, E. K., Leveillee, R. J., Messing, E. M., Miller, S. D., Peterson, A. C., Turk, T. M. T., et al. (2012) · Journal of Urology · doi:10.1016/j.juro.2012.09.078 · Cited by 482
Metadata
- Authors
- Silverman, S. G., Leyendecker, J. R., & Amis, E. S.
- Venue
- Radiology
- Published
- 2009-02
- Volume
- 250
- Issue
- 2
- Pages
- 309-323
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2130102844
- Cited by
- 298
- References
- 22
- FWCI
- 19.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What Is the Current Role of CT Urography and MR Urography in the Evaluation of the Urinary Tract? https://app.cochat.ai/papers/10.1148/radiol.2502080534
- The paper
- Silverman, S. G., Leyendecker, J. R., & Amis, E. S. (2009). What Is the Current Role of CT Urography and MR Urography in the Evaluation of the Urinary Tract? Radiology. https://doi.org/10.1148/radiol.2502080534
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.