Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 378

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Clinical Examination, Endosonography, and MR Imaging in Preoperative Assessment of Fistula in Ano: Comparison with Outcome-based Reference Standard

Buchanan, Gordon N., Halligan, Steve, Bartram, Clive I., Williams, Andrew B., Tarroni, Danilo, Cohen, C. Richard G. · 2004 · Radiology

Abstract

PURPOSE: To prospectively evaluate the relative accuracy of digital examination, anal endosonography, and magnetic resonance (MR) imaging for preoperative assessment of fistula in ano by comparison to an outcome-derived reference standard. MATERIALS AND METHODS: Ethical committee approval and informed consent were obtained. A total of 104 patients who were suspected of having fistula in ano underwent preoperative digital examination, 10-MHz anal endosonography, and body-coil MR imaging. Fistula classification was determined with each modality, with reviewers blinded to findings of other assessments. For fistula classification, an outcome-derived reference standard was based on a combination of subsequent surgical and MR imaging findings and clinical outcome after surgery. The proportion of patients correctly classified and agreement between the preoperative assessment and reference standard were determined with trend tests and kappa statistics, respectively. RESULTS: There was a significant linear trend (P < .001) in the proportion of fistula tracks (n = 108) correctly classified with each modality, as follows: clinical examination, 66 (61%) patients; endosonography, 87 (81%) patients; MR imaging, 97 (90%) patients. Similar trends were found for the correct anatomic classification of abscesses (P < .001), horseshoe extensions (P = .003), and internal openings (n = 99, P < .001); endosonography was used to correctly identify the internal opening in 90 (91%) patients versus 96 (97%) patients with MR imaging. Agreement between the outcome-derived reference standard and digital examination, endosonography, and MR imaging for classification of the primary track was fair (kappa = 0.38), good (kappa = 0.68), and very good (kappa = 0.84), respectively, and fair (kappa = 0.29), good (kappa = 0.64), and very good (kappa = 0.88), respectively, for classification of abscesses and horseshoe extensions combined. CONCLUSION: Endosonography with a high-frequency transducer is superior to digital examination for the preoperative classification of fistula in ano. While MR imaging remains superior in all respects, endosonography is a viable alternative for identification of the internal opening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2333031724

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 378

Metadata

Authors
Buchanan, G. N., Halligan, S., Bartram, C. I., Williams, A. B., Tarroni, D., & Cohen, C. R. G.
Venue
Radiology
Published
2004-12
Volume
233
Issue
3
Pages
674-681
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2136995350
Cited by
378
References
8
FWCI
8.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Examination, Endosonography, and MR Imaging in Preoperative Assessment of Fistula in Ano: Comparison with Outcome-based Reference Standard. https://app.cochat.ai/papers/10.1148/radiol.2333031724
The paper
Buchanan, G. N., Halligan, S., Bartram, C. I., Williams, A. B., Tarroni, D., & Cohen, C. R. G. (2004). Clinical Examination, Endosonography, and MR Imaging in Preoperative Assessment of Fistula in Ano: Comparison with Outcome-based Reference Standard. Radiology. https://doi.org/10.1148/radiol.2333031724

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.