The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Chronic Obstructive Pulmonary Disease: Thin-Section CT Measurement of Airway Wall Thickness and Lung Attenuation
Abstract
PURPOSE: To prospectively evaluate airway wall thickness and lung attenuation at spirometrically gated thin-section computed tomography (CT) in patients with chronic obstructive pulmonary disease (COPD) and to correlate gated CT findings with pulmonary function test (PFT) results. MATERIALS AND METHODS: The ethical committee approved the study, and all patients gave informed consent. Forty-two consecutive patients with COPD (20 with and 22 without chronic bronchitis [CB]) underwent gated thin-section CT and PFTs on the same day. The percentage wall area (PWA) and the thickness-to-diameter ratio (TDR) for all depicted bronchi that were round and larger than 2 mm in diameter, the mean lung attenuation (MLA), and the pixel index (PI) at -950 HU were determined. The reproducibility of the airway measurements was preliminarily tested by performing a five-trial examination in a patient with COPD and in a control patient. Differences in airway and lung attenuation measurements between the patients with and those without CB were evaluated at Mann-Whitney U testing. Simple and multiple regression analyses were used to assess the correlation between thin-section CT and PFT measurements. RESULTS: The mean intraoperator coefficient of variation for airway measurements was 7.8% (range, 3.8%-13.4%). An average of nine bronchi per patient were assessed. Patients with CB had significantly higher PWAs, TDRs, and MLAs and significantly lower PIs than patients without CB (P < .05 for all values). The combination of PWA, TDR, and PWA normalized to body weight correlated significantly (P < .05) with the forced expiratory volume in 1 second-to-slow vital capacity ratio and the diffusing capacity of the lung for carbon monoxide in patients with but not in patients without CB. PFT results correlated better with MLA and PI in patients without CB. CONCLUSION: Bronchial wall measurements differ between patients who have COPD with CB and those who have COPD without CB. The correlation between airway dimensions and indexes of airway obstruction in patients with COPD and CB indicates that the bronchial tree is the site of anatomic-functional alterations in this patient group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Computed Tomographic Measurements of Airway Dimensions and Emphysema in Smokers
NAKANO, Y., MURO, S., SAKAI, H., HIRAI, T., CHIN, K., TSUKINO, M., NISHIMURA, K., ITOH, H., PARÉ, P. D., HOGG, J. C., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.3.9907120 · Cited by 695
Cited by
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Self-citationLynch, D. A., Austin, J. H. M., Hogg, J. C., Grenier, P. A., Kauczor, H.-U., Bankier, A. A., Barr, R. G., Colby, T. V., Galvin, J. R., Gevenois, P. A., et al. (2015) · Radiology · doi:10.1148/radiol.2015141579 · Cited by 658
Self-citationAirflow Limitation and Airway Dimensions in Chronic Obstructive Pulmonary Disease
Hasegawa, M., Nasuhara, Y., Onodera, Y., Makita, H., Nagai, K., Fuke, S., Ito, Y., Betsuyaku, T., & Nishimura, M. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200601-037oc · Cited by 413
Martínez-García, M.-A., de la Rosa Carrillo, D., Soler-Cataluña, J.-J., Donat-Sanz, Y., Serra, P. C., Lerma, M. A., Ballestín, J., Sánchez, I. V., Selma Ferrer, M. J., Dalfo, A. R., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1518oc · Cited by 340
Computed tomographic imaging of the airways: relationship to structure and function
de Jong, P. A., Müller, N. L., Paré, P. D., & Coxson, H. O. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00007105 · Cited by 171
Metadata
- Authors
- Orlandi, I., Moroni, C., Camiciottoli, G., Bartolucci, M., Pistolesi, M., Villari, N., & Mascalchi, M.
- Venue
- Radiology
- Published
- 2005-02
- Volume
- 234
- Issue
- 2
- Pages
- 604-610
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2129736581
- Cited by
- 183
- References
- 2
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic Obstructive Pulmonary Disease: Thin-Section CT Measurement of Airway Wall Thickness and Lung Attenuation. https://app.cochat.ai/papers/10.1148/radiol.2342040013
- The paper
- Orlandi, I., Moroni, C., Camiciottoli, G., Bartolucci, M., Pistolesi, M., Villari, N., & Mascalchi, M. (2005). Chronic Obstructive Pulmonary Disease: Thin-Section CT Measurement of Airway Wall Thickness and Lung Attenuation. Radiology. https://doi.org/10.1148/radiol.2342040013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.