CoChat

Solitary Pulmonary Nodule: Characterization with Combined Wash-in and Washout Features at Dynamic Multi–Detector Row CT

Jeong, Yeon Joo, Lee, Kyung Soo, Jeong, Sun Young, Chung, Myung Jin, Shim, Sung Shine, Kim, Hojoong, Kwon, O Jung, Kim, Seonwoo · 2005 · Radiology
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively assess the accuracy of combined wash-in and washout characteristics at dynamic contrast material-enhanced multi-detector row computed tomography (CT) in distinguishing benign from malignant solitary pulmonary nodules. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. The study included 107 patients (62 men, 45 women; mean age, 55 years; range, 22-81 years) with a solitary pulmonary nodule. After unenhanced CT (2.5-mm collimation) scans were obtained, dynamic CT was performed by using a helical technique (series of images obtained throughout the nodule, with 2.5-mm collimation, at 30, 60, 90, and 120 seconds and 4, 5, 9, 12, and 15 minutes) after intravenous injection of contrast medium (120 mL). Tissue diagnosis was made in 70 nodules, and follow-up images showed benignancy in the remaining 37 (no change in size, n = 32; decrease in size, n = 5). CT findings were analyzed in terms of wash-in and washout of contrast medium. Sensitivity, specificity, and accuracy for malignant nodules were calculated by considering both the wash-in and washout characteristics at dynamic CT. RESULTS: There were 49 malignant and 58 benign nodules. When diagnostic criteria for malignancy of both wash-in of 25 HU or greater and washout of 5-31 HU were applied, sensitivity, specificity, and accuracy for malignancy were 94% (46 of 49 nodules), 90% (52 of 58 nodules), and 92% (98 of 107 nodules), respectively. Of 58 benign nodules, 27 showed less than 25 HU wash-in, 14 showed persistent contrast enhancement without washout and with wash-in of 25 HU or greater, and 11 showed washout greater than 31 HU and wash-in of 25 HU or greater. CONCLUSION: Evaluation of solitary pulmonary nodules by analyzing combined wash-in and washout characteristics at dynamic contrast-enhanced multi-detector row CT showed 92% accuracy for distinguishing benign nodules from malignant nodules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2372041549

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Jeong, Y. J., Lee, K. S., Jeong, S. Y., Chung, M. J., Shim, S. S., Kim, H., Kwon, O. J., & Kim, S.
Venue
Radiology
Published
2005-11
Volume
237
Issue
2
Pages
675-683
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2085641607
Cited by
160
References
1
FWCI
11.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Solitary Pulmonary Nodule: Characterization with Combined Wash-in and Washout Features at Dynamic Multi–Detector Row CT. https://app.cochat.ai/papers/10.1148/radiol.2372041549
The paper
Jeong, Y. J., Lee, K. S., Jeong, S. Y., Chung, M. J., Shim, S. S., Kim, H., Kwon, O. J., & Kim, S. (2005). Solitary Pulmonary Nodule: Characterization with Combined Wash-in and Washout Features at Dynamic Multi–Detector Row CT. Radiology. https://doi.org/10.1148/radiol.2372041549

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.