Solitary Pulmonary Nodule: Characterization with Combined Wash-in and Washout Features at Dynamic Multi–Detector Row CT
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively assess the accuracy of combined wash-in and washout characteristics at dynamic contrast material-enhanced multi-detector row computed tomography (CT) in distinguishing benign from malignant solitary pulmonary nodules. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. The study included 107 patients (62 men, 45 women; mean age, 55 years; range, 22-81 years) with a solitary pulmonary nodule. After unenhanced CT (2.5-mm collimation) scans were obtained, dynamic CT was performed by using a helical technique (series of images obtained throughout the nodule, with 2.5-mm collimation, at 30, 60, 90, and 120 seconds and 4, 5, 9, 12, and 15 minutes) after intravenous injection of contrast medium (120 mL). Tissue diagnosis was made in 70 nodules, and follow-up images showed benignancy in the remaining 37 (no change in size, n = 32; decrease in size, n = 5). CT findings were analyzed in terms of wash-in and washout of contrast medium. Sensitivity, specificity, and accuracy for malignant nodules were calculated by considering both the wash-in and washout characteristics at dynamic CT. RESULTS: There were 49 malignant and 58 benign nodules. When diagnostic criteria for malignancy of both wash-in of 25 HU or greater and washout of 5-31 HU were applied, sensitivity, specificity, and accuracy for malignancy were 94% (46 of 49 nodules), 90% (52 of 58 nodules), and 92% (98 of 107 nodules), respectively. Of 58 benign nodules, 27 showed less than 25 HU wash-in, 14 showed persistent contrast enhancement without washout and with wash-in of 25 HU or greater, and 11 showed washout greater than 31 HU and wash-in of 25 HU or greater. CONCLUSION: Evaluation of solitary pulmonary nodules by analyzing combined wash-in and washout characteristics at dynamic contrast-enhanced multi-detector row CT showed 92% accuracy for distinguishing benign nodules from malignant nodules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adrenal Masses: Characterization with Combined Unenhanced and Delayed Enhanced CT
Caoili, E. M., Korobkin, M., Francis, I. R., Cohan, R. H., Platt, J. F., Dunnick, N. R., & Raghupathi, K. I. (2002) · Radiology · doi:10.1148/radiol.2223010766 · Cited by 690
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612 · cited 1×
“This dose at nodule location is about five times larger than that used for single–detector row helical CT (18–19 mGy with 1–10-mm collimation, 120 kVp, 300 mAs) (29) and is about two and half times larger than that used for standard helical multi–detector row CT (39–40 mGy) performed at our instituFigure 1.”
BackgroundPeña, C. S., Boland, G. W. L., Hahn, P. F., Lee, M. J., & Mueller, P. R. (2000) · Radiology · doi:10.1148/radiology.217.3.r00dc29798 · Cited by 399
Diagnostic Efficacy of PET-FDG Imaging in Solitary Pulmonary Nodules
Dewan, N. A., Gupta, N. C., Redepenning, L. S., Phalen, J. J., & Frick, M. P. (1993) · Chest · doi:10.1378/chest.104.4.997 · Cited by 328 · cited 1×
“washout of contrast medium from the interstitial space is accelerated by active lymphatic flow (24).”
BackgroundCT of the solitary pulmonary nodule
Siegelman, S., Zerhouni, E., Leo, F., Khouri, N., & Stitik, F. (1980) · American Journal of Roentgenology · doi:10.2214/ajr.135.1.1 · Cited by 277
Solitary pulmonary nodules: evaluation of blood flow patterns with dynamic CT.
Zhang, M., & Kono, M. (1997) · Radiology · doi:10.1148/radiology.205.2.9356631 · Cited by 271 · cited 2×
“In the inflammatory nodules, the time-attenuation curve declines after reaching peak height because of normal washout (7).”
BackgroundLung nodule enhancement at CT: prospective findings.
Swensen, S. J., Brown, L. R., Colby, T. V., Weaver, A. L., & Midthun, D. E. (1996) · Radiology · doi:10.1148/radiology.201.2.8888239 · Cited by 252 · cited 3×
“In a previous study by Swensen et al (2), 44% of nodules (47 of 107) were less than 15 mm in diameter.”
MethodPulmonary nodules: CT evaluation of enhancement with iodinated contrast material.
Swensen, S. J., Brown, L. R., Colby, T. V., & Weaver, A. L. (1995) · Radiology · doi:10.1148/radiology.194.2.7824716 · Cited by 219
Adrenal adenomas and nonadenomas: assessment of washout at delayed contrast-enhanced CT.
Szolar, D. H., & Kammerhuber, F. H. (1998) · Radiology · doi:10.1148/radiology.207.2.9577483 · Cited by 218
Adrenal masses: characterization with delayed contrast-enhanced CT.
Boland, G. W., Hahn, P. F., Peña, C., & Mueller, P. R. (1997) · Radiology · doi:10.1148/radiology.202.3.9051018 · Cited by 162
Cited by
Narita, K., Akita, H., Kikuchi, E., Nakahara, T., Okuda, S., Nakatsuka, S., Oya, M., & Jinzaki, M. (2019) · BJR|case reports · doi:10.1259/bjrcr.20190012 · Cited by 11
Metadata
- Authors
- Jeong, Y. J., Lee, K. S., Jeong, S. Y., Chung, M. J., Shim, S. S., Kim, H., Kwon, O. J., & Kim, S.
- Venue
- Radiology
- Published
- 2005-11
- Volume
- 237
- Issue
- 2
- Pages
- 675-683
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2085641607
- Cited by
- 160
- References
- 14
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.