Diagnostic Architectural and Dynamic Features at Breast MR Imaging: Multicenter Study
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively determine the prevalence and predictive value of three-dimensional (3D) and dynamic breast magnetic resonance (MR) imaging and contrast material kinetic features alone and as part of predictive diagnostic models. MATERIALS AND METHODS: The study protocol was approved by the institutional review board or ethics committees of all participating institutions, and informed consent was obtained from all participants. Although study data collection was performed before HIPAA went into effect, standards that would be compliant with HIPAA were adhered to. Data from the International Breast MR Consortium trial 6883 were used in the analysis. Women underwent 3D (minimum spatial resolution, 0.7 x 1.4 x 3 mm; minimal temporal resolution, 4 minutes) and dynamic two-dimensional (temporal resolution, 15 seconds) MR imaging examinations. Readers rated enhancement shape, enhancement distribution, border architecture, enhancement intensity, presence of rim enhancement or internal septations, and the shape of the contrast material kinetic curve. Regression was performed for each feature individually and after adjustment for associated mammographic findings. Multivariate models were also constructed from multiple architectural and dynamic features. Areas under the receiver operating characteristic curve (Az values) were estimated for all models. RESULTS: There were 995 lesions in 854 women (mean age, 53 years +/- 12 [standard deviation]; range, 18-80 years) for whom pathology data were available. The absence of enhancement was associated with an 88% negative predictive value for cancer. Qualitative characterization of the dynamic enhancement pattern was associated with an Az value of 0.66 across all lesion architectures. Focal mass margins (Az = 0.76) and signal intensity (Az = 0.70) were highly predictive imaging features. Multivariate models were constructed with an Az value of 0.880. CONCLUSION: Architectural and dynamic features are important in breast MR imaging interpretation. Multivariate models involving feature assessment have a diagnostic accuracy superior to that of qualitative characterization of the dynamic enhancement pattern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Classification and Regression Trees.
Ryzin, J. V., Breiman, L., Friedman, J. H., Olshen, R. A., & Stone, C. J. (1986) · Journal of the American Statistical Association · doi:10.2307/2288003 · Cited by 20,825
Longitudinal data analysis using generalized linear models
LIANG, K.-Y., & ZEGER, S. L. (1986) · Biometrika · doi:10.1093/biomet/73.1.13 · Cited by 18,550
Multiple imputation after 18+ years
Rubin, D. B. (1996) · Journal of the American Statistical Association · doi:10.1080/01621459.1996.10476908 · Cited by 4,072
Estimating the error rate of a prediction rule: improvement on cross-validation
Efron, B. (1983) · Journal of the American Statistical Association · doi:10.1080/01621459.1983.10477973 · Cited by 2,300 · cited 1×
“To validate the Az value for each model and correct its bias, we used the bootstrap method (24).”
MethodKuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
Self-citationHarms, S. E., Flamig, D. P., Hesley, K. L., Meiches, M. D., Jensen, R. A., Evans, W. P., Savino, D. A., & Wells, R. V. (1993) · Radiology · doi:10.1148/radiology.187.2.8475297 · Cited by 634
Self-citationKuhl, C. K., Schmutzler, R. K., Leutner, C. C., Kempe, A., Wardelmann, E., Hocke, A., Maringa, M., Pfeifer, U., Krebs, D., & Schild, H. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap01267 · Cited by 538
Self-citationMagnetic Resonance Imaging of the Breast Prior to Biopsy
Bluemke, D. A. (2004) · JAMA · doi:10.1001/jama.292.22.2735 · Cited by 513
Self-citationBoetes, C., Barentsz, J. O., Mus, R. D. M., van der Sluis, R. F., van Erning, L. J. T. O., Hendriks, J. H. C. L., Holland, R., & Ruys, S. H. (1994) · Radiology · doi:10.1148/radiology.193.3.7972823 · Cited by 402
Multivariate Imputation by Chained Equations
van Buuren, S., & Groothuis‐Oudshoorn, C. G. M. (2015) · Cited by 304
Cited by
Berg, W. A. (2008) · JAMA · doi:10.1001/jama.299.18.2151 · Cited by 1,526
Breast MRI: guidelines from the European Society of Breast Imaging
Mann, R. M., Kuhl, C. K., Kinkel, K., & Boetes, C. (2008) · European Radiology · doi:10.1007/s00330-008-0863-7 · Cited by 839
Self-citationShukla‐Dave, A., Obuchowski, N. A., Chenevert, T. L., Jambawalikar, S., Schwartz, L. H., Malyarenko, D., Huang, W., Noworolski, S. M., Young, R. J., Shiroishi, M. S., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26518 · Cited by 389
Breast cancer detection using deep learning: Datasets, methods, and challenges ahead
din, N. M. U., Dar, R. A., Rasool, M., & Assad, A. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106073 · Cited by 363
The ACR BI-RADS® Experience: Learning From History
Burnside, E. S., Sickles, E. A., Bassett, L. W., Rubin, D. L., Lee, C. H., Ikeda, D. M., Mendelson, E. B., Wilcox, P. A., Butler, P. F., & D'Orsi, C. J. (2009) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2009.07.023 · Cited by 319
Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Volumetric texture analysis of breast lesions on contrast‐enhanced magnetic resonance images
Chen, W., Giger, M. L., Li, H., Bick, U., & Newstead, G. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21347 · Cited by 292
Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR Imaging
EI Khouli, R. H., Jacobs, M. A., Mezban, S. D., Huang, P., Kamel, I. R., Macura, K. J., & Bluemke, D. A. (2010) · Radiology · doi:10.1148/radiol.10091367 · Cited by 268
Self-citationPatterns of Enhancement on Breast MR Images: Interpretation and Imaging Pitfalls
Macura, K. J., Ouwerkerk, R., Jacobs, M. A., & Bluemke, D. A. (2006) · RadioGraphics · doi:10.1148/rg.266065025 · Cited by 243
“Lack of enhancement has a high negative predictive value (NPV) for malignancy (88%–96%) (12,13).”
BackgroundResultSelf-citationEl Khouli, R. H., Macura, K. J., Barker, P. B., Habba, M. R., Jacobs, M. A., & Bluemke, D. A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21947 · Cited by 213
Self-citationChen, W., Giger, M. L., Bick, U., & Newstead, G. M. (2006) · Medical Physics · doi:10.1118/1.2210568 · Cited by 211
Chen, X., Li, W.-L., Zhang, Y.-L., Wu, Q., Guo, Y.-M., & Bai, Z.-L. (2010) · BMC Cancer · doi:10.1186/1471-2407-10-693 · Cited by 209
“Numerous studies have been performed to assess the diagnostic performance of contrast-enhanced magnetic resonance imaging (MRI) in breast lesions [2-5].”
BackgroundContrast-enhanced Dedicated Breast CT: Initial Clinical Experience
Prionas, N. D., Lindfors, K. K., Ray, S., Huang, S.-Y., Beckett, L. A., Monsky, W. L., & Boone, J. M. (2010) · Radiology · doi:10.1148/radiol.10092311 · Cited by 204
Elevated tissue sodium concentration in malignant breast lesions detected with non-invasive 23Na MRI
Ouwerkerk, R., Jacobs, M. A., Macura, K. J., Wolff, A. C., Stearns, V., Mezban, S. D., Khouri, N. F., Bluemke, D. A., & Bottomley, P. A. (2007) · Breast Cancer Research and Treatment · doi:10.1007/s10549-006-9485-4 · Cited by 198
“The use of magnetic resonance imaging (MRI) in clinical breast cases is increasing due to the high sensitivity (~90‐95%) and moderate specificity (~83%) of gadolinium contrast-enhanced (CE) MRI [ 1 , 2]. The lower specificity of 1H MRI leads to additional breast”
BackgroundSelf-citationYabuuchi, H., Matsuo, Y., Okafuji, T., Kamitani, T., Soeda, H., Setoguchi, T., Sakai, S., Hatakenaka, M., Kubo, M., Sadanaga, N., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21570 · Cited by 181
Parekh, V. S., & Jacobs, M. A. (2017) · npj Breast Cancer · doi:10.1038/s41523-017-0045-3 · Cited by 158
“32,36,37 The PK-DCE quantitative metrics derived were volume transfer constant ( K trans (min − 1 )), the fractional volume of the extracellular extravascular space (EVF ( V e )), and the transfer rate constant ( k ep (min − 1 )) using commercial software DynaCad (InVivo, Gainesville, Florida).”
MethodImage standards in tissue-based diagnosis (diagnostic surgical pathology)
Kayser, K., Görtler, J., Goldmann, T., Vollmer, E., Hufnagl, P., & Kayser, G. (2008) · Diagnostic Pathology · doi:10.1186/1746-1596-3-17 · Cited by 56
“) at the hardware localization from viewing the images by radiologists and, in addition, from typing the radiologists' dictations at a different, third, location by secretaries [19,17,20,18].”
BackgroundBreast MRI: False-Negative Results and Missed Opportunities.
Korhonen, K. E., Zuckerman, S. P., Weinstein, S. P., Tobey, J., Birnbaum, J. A., McDonald, E. S., & Conant, E. F. (2021) · RadioGraphics · doi:10.1148/rg.2021200145 · Cited by 34
Metadata
- Authors
- Schnall, M. D., Blume, J., Bluemke, D. A., DeAngelis, G. A., DeBruhl, N., Harms, S., Heywang-Köbrunner, S. H., Hylton, N., Kuhl, C. K., Pisano, E. D., Causer, P., Schnitt, S. J., Thickman, D., Stelling, C. B., Weatherall, P. T., Lehman, C., & Gatsonis, C. A.
- Venue
- Radiology
- Published
- 2006-01
- Volume
- 238
- Issue
- 1
- Pages
- 42-53
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2137344154
- Cited by
- 514
- References
- 17
- FWCI
- 27.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.