Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 239

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Human Myocardium: Single-Breath-hold MR T1 Mapping with High Spatial Resolution—Reproducibility Study

Messroghli, Daniel R., Plein, Sven, Higgins, David M., Walters, Kevin, Jones, Timothy R., Ridgway, John P., Sivananthan, Mohan U.·2006·Radiology

Abstract

A prospective study approved by the local ethics committee was performed to establish the normal range and reproducibility of myocardial T1 values as assessed with single-breath-hold T1 mapping with high spatial resolution. With a 1.5-T magnetic resonance (MR) imaging system, baseline and contrast material-enhanced modified Look-Locker inversion recovery, or MOLLI, imaging was performed in 15 healthy volunteers who had given written informed consent. Image quality scores and myocardial T1 values were derived for standard short-axis segments and sections. Results were compared with those from a second MR imaging study performed on the same day (baseline only) and those from a third study performed on a different day (baseline and contrast enhanced; eight volunteers). Intra- and interobserver agreement were determined. Myocardial T1 maps were obtained rapidly in a reproducible fashion. A normal range for baseline and postcontrast myocardial T1 was established (baseline mean T1 in short-axis sections, 980 msec +/- 53 [standard deviation]; 95% confidence interval: 964, 997; number of sections, 43). This technique could enable direct quantification of changes in tissue characteristics in ischemic and inflammatory myocardial diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2382041903

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 239

Metadata

Authors
Messroghli, D. R., Plein, S., Higgins, D. M., Walters, K., Jones, T. R., Ridgway, J. P., & Sivananthan, M. U.
Venue
Radiology
Published
2006-03
Volume
238
Issue
3
Pages
1004-1012
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2001926365
Cited by
239
References
1
FWCI
3.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human Myocardium: Single-Breath-hold MR T1 Mapping with High Spatial Resolution—Reproducibility Study. https://app.cochat.ai/papers/10.1148/radiol.2382041903
The paper
Messroghli, D. R., Plein, S., Higgins, D. M., Walters, K., Jones, T. R., Ridgway, J. P., & Sivananthan, M. U. (2006). Human Myocardium: Single-Breath-hold MR T1 Mapping with High Spatial Resolution—Reproducibility Study. Radiology. https://doi.org/10.1148/radiol.2382041903

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.