The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Optimization and validation of a fully‐integrated pulse sequence for modified look‐locker inversion‐recovery (MOLLI) T1 mapping of the heart
Open accessAbstract
Purpose: To optimize and validate a fully‐integrated version of modified Look‐Locker inversion‐recovery (MOLLI) for clinical single‐breathhold cardiac T1 mapping. Materials and Methods: A MOLLI variant allowing direct access to all pulse sequence parameters was implemented on a 1.5T MR system. Varying four critical sequence parameters, MOLLI was performed in eight gadolinium‐doped agarose gel phantoms at different simulated heart rates. T1 values were derived for each variant and compared to nominal T1 values. Based on the results, MOLLI was performed in midcavity short‐axis views of 20 healthy volunteers pre‐ and post‐Gd‐DTPA. Results: In phantoms, a readout flip angle of 35°, minimum TI of 100 msec, TI increment of 80 msec, and use of three pausing heart cycles allowed for most accurate and least heart rate–dependent T1 measurements. Using this pulse sequence scheme in humans, T1 relaxation times in normal myocardium were comparable to data from previous studies, and showed narrow ranges both pre‐ and postcontrast without heart rate dependency. Conclusion: We present an optimized implementation of MOLLI for fast T1 mapping with high spatial resolution, which can be integrated into routine imaging protocols. T1 accuracy is superior to the original set of pulse sequence parameters and heart rate dependency is avoided. J. Magn. Reson. Imaging 2007;26:1081–1086. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349
Self-citationCardiovascular Magnetic Resonance in Cardiac Amyloidosis
Maceira, A. M., Joshi, J., Prasad, S. K., Moon, J. C., Perugini, E., Harding, I., Sheppard, M. N., Poole-Wilson, P. A., Hawkins, P. N., & Pennell, D. J. (2005) · Circulation · doi:10.1161/01.cir.0000152819.97857.9d · Cited by 982
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
Quantification of T1 values by SNAPSHOT-FLASH NMR imaging
Deichmann, R., & Haase, A. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90347-a · Cited by 406
Messroghli, D. R., Plein, S., Higgins, D. M., Walters, K., Jones, T. R., Ridgway, J. P., & Sivananthan, M. U. (2006) · Radiology · doi:10.1148/radiol.2382041903 · Cited by 239
Self-citationMessroghli, D., Bainbridge, G. J., Alfakih, K., Jones, T. R., Plein, S., Ridgway, J. P., & Sivananthan, M. U. (2005) · Radiology · doi:10.1148/radiol.2351040249 · Cited by 73
Self-citation
Cited by
Chin, C. W. L., Shah, A. S. V., McAllister, D. A., Joanna Cowell, S., Alam, S., Langrish, J. P., Strachan, F. E., Hunter, A. L., Maria Choy, A., Lang, C. C., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu189 · Cited by 233
Kanagala, P., Cheng, A. S. H., Singh, A., Khan, J. N., Gulsin, G. S., Patel, P., Gupta, P., Arnold, J. R., Squire, I. B., Ng, L. L., et al. (2019) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2018.11.031 · Cited by 126
Metadata
- Authors
- Messroghli, D. R., Greiser, A., Fröhlich, M., Dietz, R., & Schulz‐Menger, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-09-25
- Volume
- 26
- Issue
- 4
- Pages
- 1081-1086
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2054186815
- Cited by
- 353
- References
- 6
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization and validation of a fully‐integrated pulse sequence for modified look‐locker inversion‐recovery (MOLLI) T1 mapping of the heart. https://app.cochat.ai/papers/10.1002/jmri.21119
- The paper
- Messroghli, D. R., Greiser, A., Fröhlich, M., Dietz, R., & Schulz‐Menger, J. (2007). Optimization and validation of a fully‐integrated pulse sequence for modified look‐locker inversion‐recovery (MOLLI) T1 mapping of the heart. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.