Liver Fibrosis: Noninvasive Diagnosis with Double Contrast Material–enhanced MR Imaging

Aguirre, Diego A., Behling, Cynthia A., Alpert, Elliot, Hassanein, Tarek I., Sirlin, Claude B.·2006·Radiology

Abstract

PURPOSE: To retrospectively evaluate the accuracy of double contrast material-enhanced (hereafter double-enhanced) magnetic resonance (MR) imaging depiction of hepatic fibrosis, with histopathologic analysis findings as the reference standard. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant study and waived the requirement for informed consent. One hundred one patients (58 men, 43 women; mean age +/- standard deviation, 52 years +/- 10) who underwent double-enhanced MR imaging with superparamagnetic iron oxide (SPIO)-enhanced and double-enhanced spoiled gradient-echo (SPGR) sequences between 2001 and 2004 and had a reliable reference standard for the diagnosis of liver fibrosis were included. Two blinded MR radiologists retrospectively scored qualitative (reticulation, nodularity, and total scores) and quantitative (contrast-to-noise ratio between hyperintense and hypointense liver regions, coefficient of variation, and noise-corrected coefficient of variation) liver texture features on MR images in consensus. The image scores for patients with advanced (METAVIR fibrosis score >/= 3) versus those for patients with mild (METAVIR score </= 2) fibrosis were compared, and receiver operating characteristic curves were determined. Diagnostic performance values were calculated at the optimal operating point. Mann-Whitney U and unpaired Student t tests were performed. RESULTS: Qualitative and quantitative image scores were significantly higher for patients with METAVIR fibrosis scores of 3 or higher than for those with scores of 2 or lower (P < .001); on SPIO-enhanced SPGR images, differences increased with increasing echo time. Diagnostic performance for detection of grade 3 or more severe fibrosis was better with the double-enhanced sequence than with the SPIO-enhanced sequences, and qualitative scores had higher diagnostic performance than quantitative scores. The sensitivity, specificity, and accuracy of qualitative scores on double-enhanced SPGR images were higher than 90%. CONCLUSION: Advanced hepatic fibrosis can be detected by using double-enhanced MR imaging. Although diagnostic performance depended on the sequence and scoring system used, sensitivity, specificity, and accuracy values higher than 90% were achievable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2392050505

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Aguirre, D. A., Behling, C. A., Alpert, E., Hassanein, T. I., & Sirlin, C. B.
Venue
Radiology
Published
2006-05
Volume
239
Issue
2
Pages
425-437
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2059298139
Cited by
193
References
2
FWCI
10.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liver Fibrosis: Noninvasive Diagnosis with Double Contrast Material–enhanced MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2392050505
The paper
Aguirre, D. A., Behling, C. A., Alpert, E., Hassanein, T. I., & Sirlin, C. B. (2006). Liver Fibrosis: Noninvasive Diagnosis with Double Contrast Material–enhanced MR Imaging. Radiology. https://doi.org/10.1148/radiol.2392050505

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.