Percutaneous Pulmonary Valve Implantation Based on Rapid Prototyping of Right Ventricular Outflow Tract and Pulmonary Trunk from MR Data
Abstract
PURPOSE: To determine if magnetic resonance (MR) imaging data can be used to create rigid models that are accurate representations of the right ventricular outflow tract (RVOT) and pulmonary trunk anatomy and if such models can be used to refine the selection of patients for percutaneous pulmonary valve implantation (PPVI). MATERIALS AND METHODS: Institutional review board approval and informed patient consent were obtained. Twelve patients' MR data were analyzed and elaborated for input into a rapid prototyping (RP) system. RP models were successfully built and presented to two experienced cardiologists, who were retrospectively asked if they would have attempted PPVI. Their responses were compared with the documented decisions and outcomes of PPVI. RESULTS: For four subjects, both cardiologists correctly determined, on the basis of MR image or three-dimensional (3D) RP model findings, that PPVI should not have been attempted. Two patients in whom PPVI was attempted were considered to be unsuitable for the procedure after balloon sizing, and in another two patients, implantation was unsuccessful because of device instability. For the four patients in whom PPVI was suitable and the four in whom it was unsuitable, observers 1 and 2 correctly determined suitability for PPVI in four and two patients, respectively, by using the MR images alone. Both observers correctly determined the suitability of five patients by using the 3D models alone. CONCLUSION: Using 3D RP models resulted in more accurate selection of patients for PPVI than did using MR images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reoperation in adults with repair of tetralogy of Fallot: indications and outcomes.
Oechslin, E. N., Harrison, D. A., Harris, L., Downar, E., Webb, G. D., Siu, S. S., & Williams, W. G. (1999) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(99)70214-x · Cited by 264
Long-term results of total repair of tetralogy of Fallot in childhood.
Horneffer, P. J., Zahka, K. G., Rowe, S. A., Manolio, T. A., Gott, V. L., Reitz, B. A., & Gardner, T. J. (1990) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(90)90728-o · Cited by 120
Cited by
Cardiac 3D Printing and its Future Directions
Vukicevic, M., Mosadegh, B., Min, J. K., & Little, S. H. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.12.001 · Cited by 535
3D printing in medicine of congenital heart diseases
Yoo, S.-J., Thabit, O., Kim, E. K., Ide, H., Yim, D., Dragulescu, A., Seed, M., Grosse-Wortmann, L., & van Arsdell, G. (2016) · 3D Printing in Medicine · doi:10.1186/s41205-016-0004-x · Cited by 181
Metadata
- Authors
- Schievano, S., Migliavacca, F., Coats, L., Khambadkone, S., Carminati, M., Wilson, N., Deanfield, J. E., Bonhoeffer, P., & Taylor, A. M.
- Venue
- Radiology
- Published
- 2007-02
- Volume
- 242
- Issue
- 2
- Pages
- 490-497
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2120135586
- Cited by
- 232
- References
- 2
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous Pulmonary Valve Implantation Based on Rapid Prototyping of Right Ventricular Outflow Tract and Pulmonary Trunk from MR Data. https://app.cochat.ai/papers/10.1148/radiol.2422051994
- The paper
- Schievano, S., Migliavacca, F., Coats, L., Khambadkone, S., Carminati, M., Wilson, N., Deanfield, J. E., Bonhoeffer, P., & Taylor, A. M. (2007). Percutaneous Pulmonary Valve Implantation Based on Rapid Prototyping of Right Ventricular Outflow Tract and Pulmonary Trunk from MR Data. Radiology. https://doi.org/10.1148/radiol.2422051994
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.