CoChat

3D printing in medicine of congenital heart diseases

Open access
Yoo, Shi-Joon, Thabit, Omar, Kim, Eul Kyung, Ide, Haruki, Yim, Deane, Dragulescu, Anreea, Seed, Mike, Grosse-Wortmann, Lars, van Arsdell, Glen · 2016 · 3D Printing in Medicine

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

Congenital heart diseases causing significant hemodynamic and functional consequences require surgical repair. Understanding of the precise surgical anatomy is often challenging and can be inadequate or wrong. Modern high resolution imaging techniques and 3D printing technology allow 3D printing of the replicas of the patient's heart for precise understanding of the complex anatomy, hands-on simulation of surgical and interventional procedures, and morphology teaching of the medical professionals and patients. CT or MR images obtained with ECG-gating and breath-holding or respiration navigation are best suited for 3D printing. 3D echocardiograms are not ideal but can be used for printing limited areas of interest such as cardiac valves and ventricular septum. Although the print materials still require optimization for representation of cardiovascular tissues and valves, the surgeons find the models suitable for practicing closure of the septal defects, application of the baffles within the ventricles, reconstructing the aortic arch, and arterial switch procedure. Hands-on surgical training (HOST) on models may soon become a mandatory component of congenital heart disease surgery program. 3D printing will expand its utilization with further improvement of the use of echocardiographic data and image fusion algorithm across multiple imaging modalities and development of new printing materials. Bioprinting of implants such as stents, patches and artificial valves and tissue engineering of a part of or whole heart using the patient's own cells will open the door to a new era of personalized medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s41205-016-0004-x

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Diagram showing the steps in data processing for 3D printing. DICOM, digital imaging and communication in medicine; STL, stereolithography, standard tessellation language or standard triangle language
Fig. 1 Diagram showing the steps in data processing for 3D printing. DICOM, digital imaging and communication in medicine; STL, stereolithography, standard tessellation language or standard triangle languageCC BY · PubMed Central
Fig. 2 Segmentation process in a commercially available software program (Mimics®, Materialise, Leuven, Belgium) using magnetic resonance angiograms from a patient with congenitally corrected transposition of the great arteries with a ventricular septal defect. a Segmentation using thresholding and manual edition with a volume rendered image on the right lower panel. b Linear representation of the cardiac valvar attachments. A few points of attachment sites of each cardiac valve were marked and connected using a tool called “spline”
Fig. 2 Segmentation process in a commercially available software program (Mimics®, Materialise, Leuven, Belgium) using magnetic resonance angiograms from a patient with congenitally corrected transposition of the great arteries with a ventricular septal defect. a Segmentation using thresholding and manual edition with a volume rendered image on the right lower panel. b Linear representation of the cardiac valvar attachments. A few points of attachment sites of each cardiac valve were marked and connected using a tool called “spline”CC BY · PubMed Central
Fig. 3 Surface geometry in STL (Stereolithography or Standard Tessellation Language) file from the patient shown in Fig. 2. The surface of the object is divided into a number of triangles without any gap and overlap
Fig. 3 Surface geometry in STL (Stereolithography or Standard Tessellation Language) file from the patient shown in Fig. 2. The surface of the object is divided into a number of triangles without any gap and overlapCC BY · PubMed Central
Fig. 4 Screen-display of the STL files (a) and photographs of the corresponding models (b) in a case with so-called twisted or criss-cross heart with transposition of the great arteries and a ventricular septal defect (VSD). Cast model (top left), wall model after removal of the anterior free wall of the right atrium and right and left ventricles (top right), and wall model with the apical two thirds of the ventricles removed (bottom) are shown. The cardiac valve annuli are marked by the spline curves that were graphically designed as shown in Fig. 2B. Ao, aorta; ASD, atrial septal defect; AV, aortic valve; IVC, inferior vena cava; LA, left atrium; LAA, left atrial appendage; LV, left ventricle; MV, mitral valve; SVC, superior vena cava; TV, tricuspid valve
Fig. 4 Screen-display of the STL files (a) and photographs of the corresponding models (b) in a case with so-called twisted or criss-cross heart with transposition of the great arteries and a ventricular septal defect (VSD). Cast model (top left), wall model after removal of the anterior free wall of the right atrium and right and left ventricles (top right), and wall model with the apical two thirds of the ventricles removed (bottom) are shown. The cardiac valve annuli are marked by the spline curves that were graphically designed as shown in Fig. 2B. Ao, aorta; ASD, atrial septal defect; AV, aortic valve; IVC, inferior vena cava; LA, left atrium; LAA, left atrial appendage; LV, left ventricle; MV, mitral valve; SVC, superior vena cava; TV, tricuspid valveCC BY · PubMed Central
Fig. 5 Screen-display (a) and photograph (b) of the 3D print model of the heart with tetralogy of Fallot. The full thickness of the myocardium was carefully segmented with both endocardial and epicardial boundaries delineated by thresholding and manual editing. Although it is considered ideal, the postprocessing was time consuming and the model is stiff to be used for surgical simulation. Ao, aorta; PT, pulmonary trunk; SVC, superior vena cava; TV, tricuspid valve; RA, right atrium; RV, right ventricle; VSD, ventricular septal defect
Fig. 5 Screen-display (a) and photograph (b) of the 3D print model of the heart with tetralogy of Fallot. The full thickness of the myocardium was carefully segmented with both endocardial and epicardial boundaries delineated by thresholding and manual editing. Although it is considered ideal, the postprocessing was time consuming and the model is stiff to be used for surgical simulation. Ao, aorta; PT, pulmonary trunk; SVC, superior vena cava; TV, tricuspid valve; RA, right atrium; RV, right ventricle; VSD, ventricular septal defectCC BY · PubMed Central
Fig. 6 Models for surgical practice or training. a Screen-display of the STL file shows the heart mounted on a graphically designed platform. b Four example models for surgical training. c A 3D print model with hypoplastic left heart syndrome on which a surgeon underwent a Norwood procedure
Fig. 6 Models for surgical practice or training. a Screen-display of the STL file shows the heart mounted on a graphically designed platform. b Four example models for surgical training. c A 3D print model with hypoplastic left heart syndrome on which a surgeon underwent a Norwood procedureCC BY · PubMed Central
Fig. 7 Photographs of the 3D print models of a case with double outlet right ventricle. Although echocardiograms showed that the ventricular septal defect (VSD) is remote from both arterial valves, 3D models show that the VSD is able to be routed to the aortic valve allowing biventricular repair. Ao, aorta; AV, aortic valve; LA, left atrium; LV, left ventricle; MV, mitral valve; SVC, superior vena cava; TV, tricuspid valve; VIF, ventriculoinfundibular fold
Fig. 7 Photographs of the 3D print models of a case with double outlet right ventricle. Although echocardiograms showed that the ventricular septal defect (VSD) is remote from both arterial valves, 3D models show that the VSD is able to be routed to the aortic valve allowing biventricular repair. Ao, aorta; AV, aortic valve; LA, left atrium; LV, left ventricle; MV, mitral valve; SVC, superior vena cava; TV, tricuspid valve; VIF, ventriculoinfundibular foldCC BY · PubMed Central
Fig. 8 Photographs of the 3D print models of right ventricular outflow tract obtained in systole and diastole from a patient with severe pulmonary regurgitation after repair of tetralogy of Fallot. The fitness of the stent in the outflow tract was tested for both systole and diastole before the procedure
Fig. 8 Photographs of the 3D print models of right ventricular outflow tract obtained in systole and diastole from a patient with severe pulmonary regurgitation after repair of tetralogy of Fallot. The fitness of the stent in the outflow tract was tested for both systole and diastole before the procedureCC BY · PubMed Central
Fig. 9 Photograph of a model made of silicone using injection molding technique
Fig. 9 Photograph of a model made of silicone using injection molding techniqueCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Research works printed but not linked: 2

  1. Yoo SJ, Thabit O, Lee W, Goo HW, van Arsdell GS (2013) Double outlet right ventricle in your hands. Web publication. https://doi.org/imib-chd.com/wp-content/uploads/morphology/1-dorv-in-your-hands/DORV%20IN%20YOUR%20HANDS%2012%20CASE%20SERIES.pdf .
  2. Yoo SJ, Thabit O, Lee W, Goo HW, Yim D, Ide H, van Arsdell GS (2015) Most peculiar hearts in your hands. Criss-cross, superoinferior, twisted, topsy-turvy, etc. What do they all mean? Web publication. https://doi.org/imib-chd.com/wp-content/uploads/morphology/2-mph-in-your-hands/MOST%20PECULIAR%20HEARTS%20IN%20YOUR%20HANDS%20Full%20Pages.pdf

Cited by

See all 194

Metadata

Authors
Yoo, S.-J., Thabit, O., Kim, E. K., Ide, H., Yim, D., Dragulescu, A., Seed, M., Grosse-Wortmann, L., & van Arsdell, G.
Affiliations
University of Toronto (CA)
Corresponding author
Yoo, Shi-Joon
Venue
3D Printing in Medicine
Published
2016-12
Volume
2
Issue
1
Pages
3-3
ISSN
2365-6271 (ISSN-L)
OpenAlex
W2530815572
Cited by
181
References
42
Citations by year
2026: 7 · 2025: 17 · 2024: 26 · 2023: 24 · 2022: 24 · 2021: 17 · 2020: 17 · 2019: 14 · 2018: 21 · 2017: 13 · 2016: 1
FWCI
1.17
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0 (tdm)
Locations
  • 3D Printing in Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • TSpace (University of Toronto) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
Keywords
3D printing, congenital heart disease, surgical anatomy, surgical training, patient-specific cardiac models, ECG gating, three-dimensional echocardiography, septal defect closure, aortic arch reconstruction, arterial switch operation, bioprinting, tissue engineering, personalized medicine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D printing in medicine of congenital heart diseases. https://app.cochat.ai/papers/10.1186/s41205-016-0004-x
The paper
Yoo, S.-J., Thabit, O., Kim, E. K., Ide, H., Yim, D., Dragulescu, A., Seed, M., Grosse-Wortmann, L., & van Arsdell, G. (2016). 3D printing in medicine of congenital heart diseases. 3D Printing in Medicine. https://doi.org/10.1186/s41205-016-0004-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.